Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in August 2026.
The most recent job was on August 26, 2026.
Hurlburt Heating & Plumbing has completed 3,581 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed preventative maintenance on residential air conditioning system. Cleaned outdoor condenser unit, verified capacitor and contactor readings within manufacturer specifications, confirmed refrigerant charge adequate, cleared condensate drain line, measured 19-degree temperature differential across evaporator coil, and inspected air filter. Discussed system age and R-22 refrigerant phase-out with homeowner; unit currently operating within acceptable cooling parameters.
Responded to a water leak at the washing machine supply line. Upon inspection, identified a failed hammer arrestor as the source of the leak at the laundry hook-up connections. Removed the defective hammer arrestor and installed a new replacement unit. Verified all connections were secure, tested the water supply lines for proper operation, and confirmed no additional leaks were present. System restored to full functionality.
Responded to service call for water heater experiencing premature hot water depletion during showering. Upon inspection of the A.O. Smith ProLine Commercial Grade 50-gallon electric water heater (Model ENT-80), diagnosed faulty lower thermostat as the root cause of inadequate heating performance. Successfully replaced the defective lower thermostat, restoring proper temperature regulation and hot water capacity to the unit.
Responded to backed up main drain in basement with standing water present in floor drain. Upon arrival, noted that chemical drain cleaner had been previously attempted without success. Vacuumed standing water from floor drain opening and flushed system with high volume of water to clear blockage and restore proper drainage flow.
Responded to service call for clogged wall-mounted Kohler urinal that would not drain. Upon arrival, found unit already marked out of service. Applied chemical drain treatment (Sizzle) and agitated the blockage to restore proper drainage. Verified flush valve operation and confirmed urinal returned to normal function.
Completed follow-up plumbing work to address previously overlooked bathroom sink venting issue. The bathroom sink drainage system was operating without proper ventilation, which can lead to slow drainage, gurgling sounds, and potential sewer gas infiltration. Installed a studor vent (air admittance valve) under the sink cabinet to provide adequate venting for the drain system. The studor vent was integrated with the existing white PVC P-trap configuration, allowing atmospheric air to enter the drainage system when needed while preventing sewer gases from escaping into the living space. This solution eliminates the need for traditional roof venting and brings the plumbing installation up to proper code standards.
Completed comprehensive annual air conditioning tune-up on 12-year-old Gibson condenser unit per maintenance agreement protocol. Performed standard preventive maintenance procedures including system inspection, cleaning, and performance testing as documented on tune-up checklist form. Unit operating within normal parameters upon completion of service.
Responded to a multi-level drainage issue affecting both main and upper level bathtubs. The main level tub was experiencing complete backup while the upstairs tub exhibited severely reduced drainage rates. Upon assessment, determined the issue was related to a sewer line obstruction affecting the entire drainage system. Performed comprehensive drain cleaning procedures on both the downstairs and upstairs tub drains to clear the blockage and restore proper water flow. Following the mechanical cleaning, conducted a camera inspection of the sewer line to verify complete clearance of the obstruction and assess the overall condition of the drainage pipe. The camera inspection confirmed successful removal of the blockage and allowed for documentation of the pipe's interior condition. Both tubs were restored to full drainage capacity with no remaining backup issues.
Removed existing furnace and evaporator coil from system to allow for flooring installation. Pumped down refrigerant from AC system prior to coil removal. Documented existing gas line configuration (½" yellow gas line with wall penetration) and measured equipment dimensions (19.75" x 19.5") for future reinstallation. Relocated both furnace and coil to garage for temporary storage until new flooring is complete and equipment can be reinstalled.
Performed comprehensive AC tune-up on 8-year-old system with no customer concerns reported. Discovered air filter significantly plugged and temporarily replaced with 16x25x5 filter from stock; indoor blower and evaporator coil found clean with proper condensate drainage. Inspected outdoor condenser unit, verified all components clean, and confirmed electrical readings within manufacturer specifications including capacitor, contactor, and wiring connections. Conducted operational testing with 15-minute runtime, verified system performance with temperature split exceeding 18°F across evaporator coil. Recommended permanent filter replacement during scheduled fall furnace inspection to coordinate with annual maintenance routine. System operating properly with no deficiencies requiring immediate attention.
Responded to a water leak emergency where the primary shower was causing water intrusion in other areas of the residence. Applied silicone sealant to the shower drain assembly to prevent water from penetrating through the floor system and causing secondary damage. Replaced a defective exterior hose bib that was contributing to the overall moisture issues. All work completed to restore proper water containment and prevent further structural damage from ongoing leaks.
Completed comprehensive air conditioning tune-up and preventive maintenance on two Lennox outdoor condensing units. Performed standard seasonal maintenance protocol including inspection of electrical components, refrigerant line assessment, condenser coil cleaning, and operational testing per manufacturer specifications. Both units showed normal operating conditions with minor algae growth noted at base of one unit, typical for exterior installations in damp environments. All systems functioning properly upon completion.
Completed comprehensive AC tune-up and system inspection on residential HVAC equipment. Performed standard maintenance procedures on air handler unit, documented equipment make, model, and serial number information with detailed photographs as requested due to unknown system age. Verified proper operation of all mechanical components, condensate drain lines, and ductwork connections. System operating within normal parameters upon completion of service.
Completed comprehensive air conditioning tune-up service on residential cooling system. Upon arrival, performed visual inspection of outdoor condenser unit and identified significant accumulation of dirt and debris on coil surfaces and cabinet exterior. Customer reported elevated noise levels from outdoor fan operation prior to service. Thoroughly cleaned and washed outdoor condenser unit, removing dirt, debris, and buildup from coil fins, cabinet surfaces, and fan assembly. Following cleaning procedure, operated system through complete cooling cycle to verify proper operation and assess performance improvements. Post-service testing confirmed outdoor fan now operates at normal, near-silent sound levels, indicating successful resolution of noise concern. System running efficiently with improved airflow and heat transfer capability due to clean condenser coil surfaces.
Completed comprehensive plumbing inspection of recently remodeled bathrooms and kitchen. Identified necessary repairs at laundry washer box including replacement of supply hose, air chamber, and potentially the hot water shut-off valve due to corrosion and wear. Estimate provided for washer box valve replacement and associated components.
Completed comprehensive furnace tune-up and maintenance inspection as part of recurring preventative maintenance agreement. Verified all electrical components operating within manufacturer specifications and confirmed condensate drain lines flowing properly. Replaced dirty air filter with customer-supplied unit. Performed complete safety inspection including gas pressure verification at manifold, confirmed proper combustion with 65°F temperature rise across heat exchanger. Monitored system operation for 15 minutes with no issues detected. All components functioning normally with no safety concerns identified. Recommended maintaining supply of replacement filters for ongoing maintenance.
Replaced defective thermostat with new S40 smart thermostat under parts warranty. Removed old thermostat, installed new base plate with proper wire terminations (R, Y, G, C wiring), mounted S40 unit, configured system settings, and established remote access functionality on homeowner's mobile device for complete system control.
Installed customer-supplied brushed nickel lavatory faucet with center-set design and dual lever handles on bathroom sink. Completed installation included mounting faucet assembly to sink deck, connecting hot and cold water supply lines, and installing chrome pop-up drain assembly with proper sealing and alignment.
Responded to no cooling complaint on newer HVAC system experiencing humming noises. Diagnosed failed capacitor as root cause of cooling failure and replaced component, restoring normal system operation.
Completed comprehensive AC tune-up on 6-year-old Lennox system. Performed thorough cleaning of outdoor condenser unit, removing accumulated debris and organic buildup from coil and exterior surfaces. Conducted full electrical inspection of both outdoor and indoor components, verified proper operation of all system functions, and confirmed recent filter replacement by homeowner.