Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI between August 2026 and September 2026.
The most recent job was on September 1, 2026.
Hurlburt Heating & Plumbing has completed 3,581 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to upstairs sink drainage issue where standing water would not evacuate from basin. Upon inspection, discovered both a clogged drain line and defective waste assembly with broken stopper mechanism. Removed existing drain components and installed new waste assembly with proper sealing. Performed mechanical augering of drain line to clear blockage and restore proper flow. Tested system operation to verify complete drainage and confirmed no leaks at connections.
Responded to maintenance call for a Daikin mini split system with heavily soiled indoor unit and visible mold growth on air deflector flaps. Performed initial inspection revealing dirty filters and contamination deep within the evaporator coil assembly that was inaccessible to homeowner cleaning. Provided quote for complete indoor head unit deep cleaning service and obtained authorization, with return visit scheduled to perform thorough cleaning using specialized equipment including cleaning kit and pump sprayer.
Completed HVAC install callback following sheetrock removal by general contractor. Accessed exposed ductwork and discovered insulation material contaminating return air pathways. Removed all insulation debris from return ducts to restore proper airflow and prevent system contamination. Reinstalled ventilation grilles and verified all ductwork connections are secure and ready for drywall restoration. Site is prepared for contractor to close walls.
Replaced defective 2-stage furnace control board with new unit sourced from Johnstone supply. Upon installation, verified proper operation of both air conditioning and fan modes, confirming all control signals functioned correctly and system returned to normal operation.
Completed comprehensive HVAC maintenance agreement service on Lennox air conditioning and furnace system, both approximately 6 years old. Performed full seasonal tune-up on both units including standard inspection, cleaning, and testing procedures per manufacturer specifications. AC condenser unit serviced on exterior pad with refrigerant lines inspected and all mechanical components verified operational. Furnace system received complete tune-up with all safety controls and operational parameters checked and documented on maintenance forms. Both systems found to be functioning properly with no deficiencies noted at time of service.
Responded to callback for widespread bathroom faucet that had become unstable following previous repair attempt. Upon inspection, found the three-piece chrome faucet assembly lifting away from granite countertop surface with worsening alignment issues. Properly tightened and secured all three components of the widespread faucet installation, including both handle valves and center spout, ensuring proper mounting to countertop. Discussed replacement fixture options with customer for future consideration.
# HVAC Maintenance Summary Completed comprehensive tune-up service on both air conditioning and furnace systems, with all equipment found operating within normal parameters. Replaced air filter with customer-supplied unit and performed standard preventive maintenance procedures on both the indoor furnace unit and outdoor condensing unit. # Detailed Work Performed ## Indoor Equipment Service Performed complete maintenance inspection on gas furnace system located in basement utility area. Conducted visual inspection of unit cabinet, heat exchanger, and all associated components. Verified proper operation of blower motor and checked electrical connections for security and signs of wear. Inspected PVC vent piping and condensate drainage system for proper installation and function. Replaced existing air filter with customer-provided filter to ensure adequate airflow and system efficiency. Examined air filtration system components and confirmed proper seating of new filter media. Checke
Performed comprehensive AC tune-up on residential Carrier air conditioning system. Completed standard maintenance protocol including inspection of condenser unit, refrigerant lines, electrical connections, and all associated components. System operational and functioning within normal parameters upon completion of service.
Performed comprehensive boiler tune-up on 2-year-old unit. Upon arrival, conducted thorough inspection of all routine components with electrical readings confirming proper specifications. Initial pressure and temperature readings were within normal operating parameters. Diagnostic scan revealed stored error codes for failed ignition attempts, which were cleared from system memory. Performed maintenance by cleaning igniter and flame sensor, then flushed drain trap to ensure proper condensate drainage. Conducted operational testing to verify all systems functioning correctly, confirming temperatures, pressures, and circulation pumps operating as designed. Unit returned to full operational status with no concerns identified.
Responded to a duplex property for scheduled boiler preventative maintenance on two Weil-McLain units. Upon arrival, found first boiler completely inoperable with error code displayed and second boiler starting but failing to modulate up to heating temperature. Diagnostic testing revealed the non-operational boiler had a severely deteriorated venturi component that was burned out, rotted, and perforated with multiple holes. This unit also requires a complete maintenance/gasket kit and heat exchanger cleaning to restore proper function. On the second boiler that would start but not heat properly, discovered the heat exchanger was completely plugged with debris and buildup, preventing proper modulation and heat transfer. This unit also requires a maintenance/gasket kit for full restoration. Due to both boilers being non-functional upon arrival, converted the scheduled preventative maintenance visit to a service call. Documented all findings with photographic evidence showing the Wei
Responded to no-cool call on 1-year-old ICP system with reported water leakage pooling in furnace and overflowing onto floor. Upon inspection, discovered evaporator coil had tilted backward, preventing proper condensate drainage from the drain pan. Installed shim screw underneath coil assembly to adjust pitch forward, restoring proper drainage angle. Verified condensate now flows correctly through drain line without pooling or overflow. System operating normally with no further leakage observed.
Responded to a service call for a toilet with multiple issues including water pooling around the base and a malfunctioning flush mechanism. Upon inspection, identified a small leak in the supply line and a faulty fill valve causing the handle to malfunction and preventing proper sealing. Replaced the defective supply line and fill valve, restoring proper operation and eliminating all leaks.
Responded to no cooling complaint on residential split system. Upon arrival, found thermostat calling for cooling but equipment not operating. Diagnosed issue as furnace disconnect switch in off position, likely inadvertently turned off during recent filter change. Restored power to system and verified proper operation of both indoor and outdoor units. Noted customer had installed dual filters at furnace cabinet; recommended using single filter for proper airflow. Observed outdoor condensing unit showing age-related wear with condenser fan motor exhibiting increased resistance and stiffness during operation. System achieved greater than 20-degree temperature split across evaporator coil after power restoration. All components functioning within normal parameters at time of departure.
Responded to water leak under kitchen sink. Upon inspection, identified the basket strainer as the source of the leak. Removed the failed basket strainer and installed a new replacement unit. Tested the repair to confirm proper seal and verified no active leaks remain. System restored to full functionality.
Responded to no cooling call on 2017 Daikin system. Upon arrival, confirmed thermostat was calling for blower operation, but fan failed to run in both cooling and heating modes. Diagnostic testing revealed control board receiving proper call signal but not sending voltage output to blower motor. Determined furnace control board failure as root cause. Provided estimate for 2-stage furnace control board replacement, which was approved for repair.
Performed comprehensive AC tune-up and maintenance on a 16-year-old air conditioning system in a condo with two units. During inspection, discovered the capacitor was operating out of specification and replaced it to restore proper system function and efficiency.
Responded to no cooling complaint on residential system with operational fan. Found that condenser coils had been recently cleaned by homeowner. Placed control board into charge mode and verified refrigerant charge by measuring subcooling, which read 9.5-11.3°F against rated specification of 10°F, confirming proper charge levels. Inspected MERV 16 filter and confirmed clean condition with adequate airflow. Cycled system through complete operation and verified proper cooling function with all components operating within normal parameters.
Responded to service call for clogged toilet in basement area. Successfully cleared obstruction using drain snake equipment. Toilet restored to proper flushing operation and tested for functionality upon completion.
Completed 8-12FR air conditioning tune-up and maintenance on front AC system. Inspected evaporator coil and found heavy dirt accumulation requiring cleaning. Replaced expired humidifier pad and noted that customer's Amazon-ordered filters were incorrect specifications; unit requires proper Pure Air kit for compatibility. Changed air filter as part of routine maintenance service and verified all system components operational.
Completed comprehensive maintenance tune-up on multi-zone heating and cooling system including furnace, central air conditioning, and wood boiler. Inspected boiler heat exchanger and burners, which showed excellent condition with minimal wear; verified all zone controls operational and confirmed proper combustion. Flushed evaporator drain line, inspected recently replaced air filter, verified evaporator pan cleanliness, and cleaned condenser coils on outdoor Lennox unit. Tested all electrical components with readings within manufacturer specifications. System startup confirmed proper AC operation with 20° temperature differential across coil. Inspected wood boiler door seal, actuator, and circulation pumps—all functioning correctly. All systems operating as designed with no deficiencies noted.