Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 2, 2026.
Hurlburt Heating & Plumbing has completed 3,599 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Returned for follow-up service on no-cool complaint after allowing system to fully thaw from previous day's iced condition. Diagnosed 1989 AC system low on R-22 refrigerant. Advised customer that Pulse furnace has very limited parts availability due to age and discontinuation. Service advisor scheduled to provide replacement system estimate.
Responded to no cooling call on geothermal system. Upon arrival, system was operating normally. Performed complete tune-up and system diagnostics. Found capacitor reading 37 mfd against rated specification of 45 mfd and replaced with proper rated component. Thermostat exhibited display issues with dimming and partial screen functionality, though unit remained operational. Provided estimate for thermostat replacement. All system parameters verified within normal operating range upon departure with geothermal unit cooling properly.
Completed comprehensive plumbing inspection of residential property as part of recurring maintenance program. Documented water heater installation dated June 5, 2023, including copper supply lines, gas connections with yellow-handled shut-off valves, and flexible gas line routing. Identified multiple service needs including bathroom sink drain operating sluggishly due to partial obstruction in P-trap assembly, utility sink faucet requiring valve adjustment or replacement due to stiff operation, and toilet seat needing replacement with ivory standard model. Noted audible squeaking noise originating from plumbing system when shower is activated, likely caused by water hammer or loose pipe mounting. Photographed water heater installation showing proper gas line configuration and under-sink plumbing assembly with PVC drain connections for documentation and future reference.
Completed comprehensive HVAC maintenance agreement service including full furnace and air conditioning system tune-up inspections. Performed thorough furnace inspection with focus on heat exchanger condition, inducer motor operation, and all safety controls; heat exchanger shows good condition with no cracks or deterioration, though inducer motor exhibits slightly elevated noise levels during operation but remains within acceptable parameters. Conducted complete air conditioning system evaluation including inspection of refrigerant lines, condensate drainage system, blower motor assembly, electrical connections, and all mechanical components; all systems operating properly with no issues identified and equipment showing normal wear consistent with age.
Installed whole home water filtration system with new carbon filter unit mounted to utility room wall. Connected filtration system to existing plumbing infrastructure using PVC piping, integrated with water heater supply line, and verified proper operation of all shut-off valves and pressure regulation components.
Responded to callback for Lennox SL28XCV-036 system displaying error code 411 and "OU- low pressure switch lock out" with unit failing to start. Found stored 411 alert indicating temporary pressure-safety or sensor/wiring fault that was no longer active. Performed system power cycle and reset, confirmed S30 thermostat restored communication and connectivity. Removed outdoor unit cover and inspected all wiring connections, top-cap low-pressure switch, and high-pressure transducer harness for loose connections or visible damage—all connections secure. Ran cooling test mode and verified normal operating pressures with acceptable subcooling and superheat readings in both low and high cooling stages. System currently operating normally with alert cleared from active status and remaining in history only. Advised monitoring system operation and recommended that if code 411 returns, further diagnostic work should focus on low-pressure switch circuit, high-pressure transducer wiring, and contro
Responded to no-cooling complaint on ThermalZone outdoor condensing unit at residential property where new homeowner reported system failed to reach setpoint after initial 8-hour operation. Performed diagnostic evaluation on unit with missing model/serial data plate, preventing exact age verification. Measured incoming voltage at 246V and tested dual run capacitor rated 30/5 µF, which measured 29.5/5 µF within acceptable tolerance. Verified all wiring connections to compressor and condenser fan motor. Upon thermostat call for cooling, observed condenser fan motor energized but fan blade assembly exhibited extreme stiffness requiring manual assistance to rotate, indicating failed condenser fan motor with seized bearings rather than capacitor failure. Advised homeowner that unit appears to be legacy R-22 equipment based on age and configuration, complicating repair decisions due to refrigerant obsolescence. Discussed implications of planned backyard project requiring potential condenser
Completed comprehensive seasonal maintenance on residential ductless mini-split system and boiler per promotional tune-up service. Performed full inspection, cleaning, and operational testing on outdoor condenser unit and indoor wall-mounted air handler. All components found to be functioning within normal parameters. Boiler system also inspected and serviced according to standard maintenance protocols.
Replaced 2-inch spin-down sediment filter on whole home water treatment system to address low water pressure issues. Installed new shower cartridges to resolve leaking in shower valve assembly. Repaired dripping bathtub faucet to eliminate water waste and restore proper operation.
Responded to callback for second opinion on water treatment system performance issues. Upon inspection, confirmed well supply insufficient to maintain flow demand for neutralizer system. Observed Pentair Wellmate pressure tank and dual-tank water treatment system with digital control valves. Determined issue related to well pump depth and water recovery rate rather than recently replaced equipment. Recommended contacting well service contractor to evaluate pump placement and potentially lower pump assembly to access deeper water table for improved flow capacity.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, found evaporator coil completely iced over, preventing proper heat transfer and airflow. System unable to maintain desired temperature of 66°F, only reaching 76°F. Advised homeowner to power down unit to allow complete thawing of ice buildup before further diagnosis. Return visit scheduled to determine root cause of icing condition, which may include low refrigerant charge, restricted airflow, or failed blower motor components.
Completed boiler preventive maintenance and relocated outdoor temperature sensor to back of garage after original mounting location on staircase was removed. Addressed fan pressure error by thoroughly cleaning dirty heat exchanger and flushing system, cleaned condensate trap and flame sensor, verified proper operation of circulation pumps and expansion tank, and bled all cast iron radiators to ensure proper heating throughout. System now operating correctly with all errors resolved.
Responded to no cooling complaint with system freezing up. Upon inspection, found heavily soiled evaporator coil, blower wheel, and secondary drain pan with significant dust and debris accumulation, contrary to initial report that coil was clean. Performed thorough cleaning of evaporator coil, blower wheel, and secondary drain pan to restore proper airflow. After cleaning, connected manifold gauges and tested system operation. Unit now operating without freezing, providing adequate cooling. System appears slightly low on refrigerant charge but is functional. Homeowner elected to monitor system performance and defer refrigerant charge at this time.
Responded to no cooling complaint on geothermal system. Found air filter collapsed against evaporator coil, causing restricted airflow and coil freezing. Replaced filter and diagnosed freezing issue as either faulty TXV or low refrigerant charge in R22 system. During inspection, identified failed in-floor heat pump circulator and leaking automatic air vent requiring attention. Due to age of equipment (20 years) and R22 refrigerant phase-out considerations, scheduled follow-up appointment to provide system replacement options.
Responded to water leak in basement at abandoned washing machine hookup location. Upon inspection, found leaking shut-off valves on old CPVC plumbing lines that were no longer in service. Removed the abandoned washing machine hookup assembly and properly capped the CPVC supply lines to eliminate the leak and prevent future water damage.
Responded to no cooling complaint on 19-year-old WaterFurnace geothermal heat pump system. Diagnosed thermostat malfunction preventing proper communication with heat pump unit. Replaced faulty thermostat with compatible model, verified proper wiring connections, and tested system operation through complete cooling cycle to confirm restoration of normal function.
Responded to no cooling call on residential air conditioning system. Upon arrival, found compressor not starting. Tested capacitor and confirmed low readings, replaced with new capacitor. After replacement, unit still failed to produce cooling. Connected manifold gauges to system and discovered refrigerant charge was depleted. Due to age of unit and extent of repairs needed, coordinated with service advisor to schedule follow-up appointment for comprehensive system evaluation and refrigerant leak diagnosis.
Responded to a no-water issue at a public restroom toilet. Upon inspection, discovered significant sediment buildup in both the angle stop valve and toilet supply line, preventing water flow to the fixture. Disassembled the angle stop, thoroughly flushed the valve body and connections to remove accumulated debris, and installed a new braided stainless steel toilet supply line to restore proper water delivery to the tank.
Performed comprehensive AC tune-up on 2-year-old system. Inspected and verified filters and blower assembly were clean and properly balanced. Confirmed evaporator coil was clean with proper condensate drainage. Conducted routine electrical inspection on outdoor unit, cleaned condenser coil, and verified all components within normal operating parameters. System tested for 15 minutes with temperature differential exceeding 18 degrees, confirming optimal performance with no issues identified.
Responded to service call for condensate pump replacement on three mini split indoor units. Upon inspection, determined two units were gravity draining directly through sidewall and did not require pump installation. Disassembled these two heads, performed thorough cleaning of drain lines, and cleared blockages to restore proper drainage function. Recommended annual preventative maintenance to prevent future drain line obstructions. The third mini split head in master bedroom, mounted above window on exterior wall, had existing failed condensate pump requiring replacement. Removed defective pump and attempted installation of new 115V condensate pump. During installation, discovered replacement pump housing was too large to fit in available space behind indoor unit where original pump was mounted. Reinstalled indoor unit cover and verified other two units operating correctly with proper drainage. Advised that alternative compact condensate pump must be sourced and ordered for proper i