Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 9, 2026.
Hurlburt Heating & Plumbing has completed 3,599 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to a slow-draining bathroom sink on the main floor. Inspected and found the P-trap clear of obstructions. Snaked the drain line from the fixture arm through to the three-inch stack to remove buildup causing the blockage. Provided estimate for services and successfully cleared the line, restoring proper drainage function.
Responded to main floor toilet leaking into basement upon flushing. Removed and reset toilet after confirming failed wax seal. Discovered toilet drain line extremely backed up due to reported frequent flushing of wipes. Attempted to clear blockage but obstruction proved too severe for standard augering equipment. Installed new wax ring and reinstalled toilet to stop active leak. Coordinated same-day follow-up visit with drain specialist equipped with appropriate tools to clear stubborn blockage in main drain line.
Completed comprehensive maintenance agreement tune-up on 8-year-old air conditioning system and 11-year-old furnace. Performed full system inspection per maintenance protocol, documented filter specifications (20x25x6 with airflow direction marked), verified all components operating within manufacturer specifications, and completed required preventative maintenance procedures on both heating and cooling equipment.
Responded to active water leak in basement originating from galvanized pipe in wall serving kitchen sink drain arm. Upon inspection, identified corroded galvanized piping as source of leak, with previous unsuccessful DIY repair attempt evident. Removed deteriorated galvanized pipe section and replaced entire run to kitchen sink with new piping. Installed new supply lines to ensure proper water delivery and prevent future leakage. Tested all connections for leaks and verified proper drainage function. Photographed work area showing mechanical room location and completed repairs.
Performed comprehensive maintenance on 2014 Goodman air conditioner and two-stage gas furnace system. Verified refrigerant charge, electrical components, gas pressure, and overall efficiency within manufacturer specifications. Corrected line-set vibration at house penetration point. Inspected heat exchanger with no cracks, holes, or splits detected. Confirmed blower wheel and cage clean and in good condition. Flushed evaporator drain pan and condensate line. Both heating and cooling systems operating properly with no additional issues identified.
Responded to callback for gas odor complaint at residence where water heater was previously installed. Upon inspection, identified gas leak occurring through exhaust vent during unit operation. Diagnostic testing confirmed water heater was over-firing, causing combustion gases to escape through the exhaust system rather than venting properly. Documented mechanical components including gas valve assembly, control wiring, and venting configuration with photographs for further evaluation. Unit requires combustion analysis and gas pressure adjustment by certified technician to correct over-firing condition and ensure safe operation within manufacturer specifications.
Completed comprehensive boiler preventive maintenance and tune-up service. During inspection, discovered a slightly warped venturi causing minor gas leakage when cold; the component expands when heated, temporarily sealing the leak. Recommended maintenance kit installation as previous service history indicated overdue maintenance. Thoroughly inspected and verified proper operation of circulator pumps, expansion tank, and all associated system components. Documented findings with photos, initiated part order form for repair pricing, and coordinated advisor consultation for replacement system options.
Responded to service call to install customer-supplied shower trim. Upon inspection, determined that the purchased trim was incompatible with the existing shower valve assembly. Assessed the current valve configuration and informed customer that complete shower valve and trim replacement would be necessary to proceed with installation. Provided estimate for full valve and trim replacement to resolve compatibility issue.
Responded to residential HVAC system experiencing cooling issues. Diagnosed low refrigerant charge and failing capacitor as primary concerns. Replaced dual run capacitor with new 35/5 MFD unit and restored proper electrical operation to compressor and condenser fan motor. Added approximately one pound of R410A refrigerant to system, monitoring subcooling temperature to achieve target range of 10°F ±3°F. Final subcooling measurement stabilized at 12°F, confirming proper refrigerant charge. Verified system operation with air conditioning cooling effectively and all components functioning within normal parameters.
Responded to leaking shower valve located in exterior wall. Upon inspection, discovered valve stem had broken off at pipe connection inside wall cavity. Due to location and lack of access panel, determined that tile removal would be required for proper valve replacement. As temporary solution to restore water service to residence, cut and capped supply lines feeding the shower fixture. Water supply to remainder of home successfully restored. Homeowner opted to defer permanent shower valve repair and schedule comprehensive bathroom remodel estimate to address shower system and surrounding tile work.
Completed recurring plumbing inspection for residential property with all plumbing systems found to be in good working order. Noted electrical safety concern with exposed wiring and wire nuts protruding from junction box in unfinished area, requiring attention from licensed electrician. Documented conditions with photographs including basement plumbing infrastructure with copper piping and electrical rough-in work.
Completed scheduled furnace tune-up on 3-year-old Lennox heating system as part of maintenance agreement. Replaced air filter, verified blower and evaporator coils were clean with no debris accumulation. Performed comprehensive electrical inspection with all components reading within manufacturer specifications. Verified proper gas pressures, conducted thorough heat exchanger inspection with no cracks or compromises detected. Tested furnace operation with 15-minute runtime, confirmed proper cycling and measured temperature rise of approximately 55°F across the heat exchanger, indicating optimal combustion efficiency. All systems operating normally with no concerns identified.
Responded to no cooling call on 1988 R22 system and diagnosed plugged condenser coil and failed capacitor. Due to advanced age of equipment, presented both replacement and repair options to customer. Customer elected to proceed with repairs, so replaced capacitor and disassembled and thoroughly cleaned condenser coil. System pressures verified within acceptable range post-service with 17-degree temperature split across evaporator coil, confirming adequate cooling operation restored, though longevity of aging unit cannot be guaranteed.
Performed furnace maintenance on 26-year-old system using promotional coupon. Tested system operation in both first and second stage heating modes. Discovered foam debris lodged in blower wheel, which correlated with unusual sounds reported by homeowner over recent weeks. Unable to verify gas pressure readings due to inoperable gas shutoff valve that would not turn. Recommended scheduling equipment replacement consultation for both furnace and air conditioning system due to age of equipment and current mechanical issues. Documentation photos captured of system components and workspace conditions.
Responded to water leaking issue near furnace system. Found condensate pump overflowing onto basement floor due to plugged pump mechanism and blocked drain line. Cleaned condensate pump assembly and flushed drain line to restore proper drainage function. System tested and confirmed operational with no further water accumulation.
Responded to commercial toilet service call for non-functional flush handle. Upon inspection, found the trip lever mechanism inside the tank had failed, preventing proper toilet operation. Removed tank lid, assessed internal components, and successfully replaced the broken trip lever assembly with new hardware. Tested flush mechanism to ensure proper operation and restored toilet to full working condition.
Replaced failed condensate pump on mini-split head and cleared plugged drain line from evaporator to pump reservoir. Verified proper drainage operation through multiple test cycles and confirmed all three mini-split heads are functioning correctly. Additionally secured loose corner trim piece on secondary head unit.
Responded to service call for non-functional refrigerator shut-off valve preventing water supply isolation for appliance replacement. Accessed plumbing infrastructure in basement ceiling space and located existing refrigerator supply line valve. Removed failed shut-off valve from copper water supply line and installed new chrome valve assembly with proper fittings. Tested new valve for proper operation and verified complete water shut-off capability. Customer now able to proceed with new refrigerator installation.
Responded to service call for low water pressure and no hot water at property with well water system. Upon inspection, diagnosed clogged and damaged inlet screen filter on cold water supply line to water heating system. Removed compromised filter component, cleaned debris from screen, and temporarily reinstalled cleaned filter to restore water flow and hot water functionality. Ordered replacement filter assembly for permanent repair. Documented existing Navien tankless water heater installation with associated plumbing connections, expansion tank, and gas line. Customer advised of temporary repair and pending replacement part installation.
Responded to service call for basement toilet that was constantly running. Upon inspection, determined that the fill valve was leaking and failing to shut off properly, causing continuous water flow into the tank. Replaced the defective fill valve with new unit, tested operation to ensure proper function and water shutoff. Toilet is now operating normally without continuous running.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.