Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 10, 2026.
Hurlburt Heating & Plumbing has completed 3,599 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to emergency callback for newly installed water heater reported smoking with potential fire hazard. Upon inspection, identified electrical wiring issues with the unit's power supply connections. Documented electrical components and wiring configuration with photos showing improper connections at the junction box. Immediately dispatched licensed electrician to address the electrical deficiencies and ensure safe operation of the water heater installation.
Performed comprehensive furnace maintenance tune-up on a 9-year-old Goodman heating system. Upon inspection, identified and addressed a condensate leak originating from a loose hose clamp connection. Tightened and secured the hose clamp to eliminate moisture discharge. Inspected electrical panel and connections, verified proper circuit operation, and examined air filter condition. System operating properly with no additional issues noted at time of service completion.
Responded to gas odor complaint and performed combustion analysis on IBC water heater. Found unit over-firing with low fire combustion readings outside manufacturer specifications, which was causing gas smell from boiler exhaust. Adjusted and calibrated combustion settings to meet manufacturer specifications, resolving the safety hazard and restoring proper operation.
Completed preventive maintenance on a 12-year-old furnace for homeowner preparing for winter season. Performed comprehensive inspection of all routine components including burners, heat exchanger, blower assembly, and safety controls. Cleaned necessary components and verified all systems are operating within manufacturer specifications. No deficiencies or safety concerns identified; unit is functioning properly and ready for heating season.
Responded to no hot water complaint at residential property. Upon arrival, diagnosed failed water heater with active leak. Removed existing compromised unit and installed new tanked water heater. Completed all necessary plumbing connections, verified proper operation, and restored hot water service to the home.
Responded to emergency plumbing call for broken toilet supply line in 70-year-old residential property with original plumbing infrastructure. Upon arrival, found water supply had been shut off to prevent further damage. Inspection revealed the 3/8-inch supply line to the toilet had completely snapped off at the connection point, requiring immediate replacement. Assessed the extent of damage to surrounding wall and floor areas, which showed significant deterioration from water exposure. The wall exhibited exposed substrate materials, including damaged drywall and backing board, with visible copper piping within the wall cavity. Floor area contained debris from deteriorated building materials and evidence of prolonged moisture intrusion. Removed the failed 3/8-inch toilet supply line and prepared connection points for new installation. Verified the integrity of the shutoff valve and connection threads to ensure proper seal. Installed new 3/8-inch braided stainless steel supply line wit
Completed comprehensive tune-up on one-year-old furnace and AC system with no customer concerns reported. Performed full maintenance procedures per checklist, noting air filter was due for replacement which customer will handle independently. Tested both heating and cooling modes from thermostat, running each system for 15 minutes with successful operation—achieved 55° temperature rise with gas furnace and heat pump, and 18° temperature drop in cooling mode. All equipment operating within normal parameters with no issues identified.
Responded to a water leak originating from a laundry room sink drain pipe. Upon inspection through an existing access opening, identified a loose plastic retaining nut on the drain assembly as the source of the leak. Tightened the plastic nut on the drain assembly to manufacturer specifications, securing the connection and resolving the leak. No water shutoff was required to complete the repair.
Responded to HVAC install callback to address electrical safety concern. Found high voltage wire from electrical panel to furnace lacked proper ground conductor, though wire gauge was appropriate for existing 20-amp breaker. Ran new 14/2 line voltage wire from panel to furnace through challenging route with multiple obstacles. Replaced 20-amp circuit breaker with properly sized 15-amp breaker to match new wire gauge and ensure code compliance. Verified all connections and tested system operation upon completion.
Completed comprehensive furnace maintenance on a 3-year-old Lennox heating system that had not been serviced since installation. Performed standard tune-up procedures including inspection of all internal components, burner assembly, blower motor, electrical connections, and safety controls. Conducted electrical diagnostics using digital multimeter to verify proper system operation and voltage readings. Noted significant dust and debris accumulation in ductwork throughout the system. System is currently operating properly with all components functioning as designed. Provided estimate for professional duct cleaning services to address accumulated debris and improve system efficiency and indoor air quality.
Responded to gas leak emergency on 1-year-old HVAC system where private gas line was damaged by chainsaw during yard work. Upon arrival, confirmed gas meter had been locked and tagged out by Xcel Energy Cooperative due to active leak in 3/8" copper gas line. Performed thorough inspection and documentation of the damaged line, which showed visible breach in the copper tubing near the HVAC unit exterior. Photographed damage site showing compromised gas line section among landscaping area with mulch and vegetation. System was non-operational due to gas supply shutoff for safety. Ordered replacement parts for copper gas line repair and scheduled return visit for permanent repair once materials arrive. Ensured site remained safe and secure with utility lockout in place.
Completed recurring plumbing inspection of residential property. Observed high water pressure and hard water conditions throughout the system. Inspected Bradford White Aerotherm Series water heater and associated plumbing connections in basement utility area. Recommended installation of pressure reducing valve to protect fixtures and appliances from damage due to excessive water pressure.
Completed comprehensive annual maintenance tune-up on 5-year-old furnace and air conditioning system per maintenance agreement. Performed thorough inspection of all routine components on both systems, finding equipment clean and operating within manufacturer specifications. Noted air filter required replacement and outdoor condenser coil needed cleaning due to accumulated debris. Conducted operational testing of furnace with 15-minute runtime evaluation, confirming proper functionality with 55° temperature rise across heat exchanger. Verified gas pressures at inlet and manifold within acceptable range and inspected venting system for proper draft and clearances. All combustion components, burners, and flame sensor showed normal operation. Tested air conditioning system operation with 15-minute runtime, achieving 24° temperature split across evaporator coil, indicating adequate refrigerant charge and proper system performance. Verified compressor amperage, capacitor readings, and cond
Completed comprehensive furnace tune-up and preventive maintenance on 14-year-old heating unit. Performed thorough inspection of all electrical components, verified proper operation of ignition system and burner assembly with clean blue flame combustion across all burners. Checked and confirmed condensate drain lines were clear and unobstructed. Replaced dirty air filter with customer-supplied unit. Inspected blower assembly, evaporator coil, and secondary heat exchanger—all found clean and in good operating condition. Conducted extended operational test running system for 15 minutes, confirming proper cycling and achieving optimal 50-degree temperature rise across heat exchanger. All safety controls, electrical connections, and mechanical components functioning within normal parameters. Unit operating efficiently with no concerns identified.
Completed warranty repair on Lennox furnace by replacing defective furnace door panel. Unit tested and confirmed operational upon completion.
Performed comprehensive air conditioning tune-up and safety inspection on 17-year-old system. Identified weak dual capacitor requiring replacement and extremely aged humidifier unit. Conducted ductwork inspection using camera scope to assess interior condition, evaluated air filtration system, and documented findings with photographic evidence for comfort advisor consultation regarding recommended component replacements.
Responded to a severely backed-up toilet at a group home facility. Upon inspection, discovered a red substitute wax ring lodged in the 90-degree elbow of the drain stack, causing the complete blockage. Successfully retrieved the obstructing ring from the stack, cleared the drain line, and properly reset the toilet with appropriate sealing to restore full functionality.
Replaced non-adjustable fill valves with adjustable units on two toilets to address slow tank filling issues. Throttled down water flow to the bowl to prioritize faster tank refilling, resulting in a 90-second fill time for the upstairs toilet and improved performance on the smaller downstairs unit. Advised that if adjustable valves do not resolve the filling concerns, complete toilet replacement would be the remaining solution.
Removed existing bidet attachment from toilet due to accessibility concerns and replaced with elongated toilet seat to accommodate customer's mobility requirements. Disconnected water supply line to bidet unit, removed mounting hardware, and reinstalled standard seat configuration. Verified proper fit and functionality of new elongated seat to ensure improved accessibility and comfort for customer with disability needs.
# Plumbing Service - Broken Toilet Stub Out Responded to service call for leaking pipe in bathroom. Upon arrival, performed thorough inspection of the affected area and identified a broken toilet stub out as the source of the water leak. The toilet flange connection had fractured, with the stub out pipe broken off at the structural framing level. Documented extensive water damage to surrounding wall surfaces, including deteriorated drywall, delaminated paint layers, and compromised plaster materials in the corner section where walls meet. Inspection revealed the damaged PVC plumbing line running through the wall cavity behind compromised surface materials. Access opening exposed wooden structural framing and the full extent of the broken pipe connection. Provided comprehensive assessment of repair requirements, including removal of damaged wall materials, replacement of broken toilet stub out fitting, proper reconnection to existing plumbing line, and restoration of wall surfaces. R