Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 11, 2026.
Hurlburt Heating & Plumbing has completed 3,599 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Performed comprehensive furnace tune-up on 3-year-old Lennox unit including flame sensor cleaning, complete electrical system testing, and air filter replacement. All electrical components tested within manufacturer specifications and unit confirmed operating properly. Customer declined exterior AC unit inspection that was initially requested regarding potential code compliance concerns about clearance distance from structure.
Responded to emergency water leak causing visible damage to interior walls and ceiling. Upon inspection, determined leak was not originating from secondary bathroom sink as initially suspected, but was caused by condensation accumulation on HVAC ductwork in attic space. Examined ductwork and identified inadequate insulation allowing moisture to form and drip onto ceiling below, resulting in water staining and structural concerns. Documented conditions with photographs of affected ductwork, wooden framing, and mechanical equipment. Recommended scheduling HVAC technician for proper return visit to address condensation issue through improved duct insulation or vapor barrier installation to prevent future moisture damage.
Completed furnace maintenance on 1-year-old Lennox system per customer request (service changed from AC tune-up upon arrival). Performed comprehensive furnace tune-up including steam cleaning of flame sensor and full electrical testing. All electrical components tested within manufacturer specifications and system confirmed operating properly.
Completed scheduled furnace tune-up on 3-year-old residential heating unit. Performed comprehensive maintenance including flame sensor cleaning, electrical testing and verification of all system parameters within manufacturer specifications. Confirmed proper unit operation, verified air filter condition, and recorded temperature readings. All components functioning normally with no issues identified.
Responded to a basement bathroom emergency involving backed-up shower and toilet fixtures. Upon arrival, found approximately 4 inches of standing water with rust-colored sediment in the shower base and a non-draining toilet. Initial customer attempts with chemical drain cleaner and plunger had been unsuccessful and caused cross-contamination between fixtures, indicating a main line blockage. Deployed rigid drain cleaning machine to snake the main drainage line. Located and removed a cloth or diaper obstruction at 27 feet from the access point. Continued mechanical cleaning to address approximately 3 feet of solid grease buildup in the pipe downstream from the initial blockage. Successfully cleared the line and restored proper drainage to all affected fixtures. Documented site conditions with photographs showing the standing water discoloration and shower pan condition prior to service completion.
Responded to callback for commercial urinal continuously running water despite previous sensor cleaning. Performed thorough investigation of flush valve assembly and determined sensor cleaning was insufficient to resolve issue. Urinal observed flushing intermittently on its own, indicating internal flush valve failure. Ordered replacement flush valve assembly and temporarily shut off water supply to unit to prevent water waste until new valve can be installed.
Completed comprehensive furnace tune-up on 4-year-old Goodman unit (Model GM9536105050, Serial S119890). Addressed customer concern regarding water leakage from evaporator coil corner by inspecting area, removing debris accumulation from beneath evaporator, and securing loose ductwork connection at back right corner that was previously unfastened. All furnace components inspected and found operating within normal parameters.
Completed annual air conditioning tuneup and inspection on residential outdoor condensing unit. During inspection, discovered significant damage to condenser coils including a large hole caused by dog urine corrosion. Condenser fan motor exhibited hard-start condition requiring manual assistance to initiate operation. Overall coil condition is severely deteriorated. Recommended either replacing the condenser fan motor as a short-term repair or considering full AC unit replacement due to extent of coil damage and age of equipment.
Responded to service call for Lennox outdoor condensing unit experiencing operational issues. Diagnosed faulty control board and ordered replacement part under manufacturer warranty. Upon arrival of warranty component, replaced defective control board and restored system to proper operation. Conducted operational testing to verify all functions working correctly. Unit now operating as designed with no further issues detected.
Responded to commercial urinal continuously running and flushing on its own. Upon inspection, identified dirty sensor on automatic flush valve assembly causing false activation. Cleaned sensor on Kohler wall-mounted urinal flush valve system, restoring proper operation and resolving continuous water flow issue.
Replaced existing 17-year-old toilet with new ADA-compliant round bowl toilet. Installed new shut-off valve and water supply line to ensure proper function and code compliance. Unit tested successfully with no leaks detected.
Responded to no cooling and no heating complaint on system installed two years ago. Diagnosed failed contactor on outdoor condensing unit which was causing electrical issues that tripped the furnace fuse. Replaced defective contactor, restored power to system, and verified proper operation of both cooling and heating functions.
Responded to a water leak originating from an upstairs toilet that was causing damage to the lower level. Upon arrival, identified active water pooling on the bathroom floor adjacent to the toilet fixture. Removed the toilet from its mounting position to inspect the underlying flange and wax seal. Discovered a broken toilet flange that had compromised the seal integrity, allowing water to escape during toilet use and flush cycles. Removed the damaged flange and installed a new replacement flange to manufacturer specifications. Reset the toilet onto the new flange with a fresh wax ring seal, ensuring proper alignment and secure mounting. Reconnected the water supply line and tested the toilet through multiple flush cycles to verify leak elimination and proper drainage function.
Returned to address water flow restriction identified during well system inspection. The original installation utilized 3/4-inch piping connected to a 1-inch connection point on the Pentair Wellmate pressure tank, creating a bottleneck that impeded proper water flow. Removed the undersized 3/4-inch water line and replaced it with 1-inch piping to match the tank connection specifications, ensuring proper flow capacity throughout the system. Water testing was performed post-installation to verify system performance and water quality parameters.
Completed comprehensive maintenance inspection on both air conditioning unit and furnace as part of final agreement service before property transition. The 35-year-old AC system and 5-year-old furnace were thoroughly evaluated, with all components checked, tested, and documented. All maintenance procedures were performed according to manufacturer specifications, with system operations verified and photographic documentation captured of key mechanical components including condensate drainage connections and ductwork installations.
Responded to no cooling complaint on 10-year-old Heil system where indoor temperature had risen 6 degrees despite AC operation. Diagnosed blower motor operating at significantly reduced RPM during cooling mode, while functioning normally in heating and fan-only modes. Identified failed blower motor module as root cause of inadequate airflow and cooling performance. Provided diagnostic findings and recommended replacement estimate for blower motor assembly to restore proper system operation.
Responded to no cooling complaint on system installed one year prior. Upon arrival, diagnosed outdoor unit short cycling due to low refrigerant pressure. Added 2.5 pounds of R454-B refrigerant to restore proper system operation and charging levels. Injected UV dye into refrigerant circuit for future leak detection and monitoring. System returned to normal cooling operation upon completion.
Responded to no cooling complaint on Ruud HVAC system less than 10 years old. Upon arrival, found red indicator light on furnace panel and outdoor unit fan not engaging. Diagnosed furnace running inducer motor only with no further operation. Connected to unit via mobile diagnostic interface and retrieved fault code indicating flame sense error without gas valve energization. Code returned immediately upon clearing, indicating persistent control issue. Inspection revealed missing ground wire connection at furnace. Temporarily connected ground to MC cable sheath to test if grounding issue was causing fault code, but error persisted, confirming control board failure as root cause. Verified all other electrical connections and wiring integrity within control panel. Documented control board part number and unit information for warranty verification and parts ordering. Submitted part order form for replacement control board with warranty status inquiry. Noted need for proper ground wire
Returned to address water leak at previously installed press fitting. Upon inspection, discovered the copper pipe was extremely thin and soft, preventing proper seal with press connection. Removed failed press fitting and soldered a new adapter directly onto the copper pipe to ensure watertight connection. Completed repair and verified system integrity.
Responded to complaint of overheating condition in Room 4 with leaking heat register. Upon inspection, discovered zone valve actuator head had been dislodged from valve body, causing zone to remain in open position and allowing continuous water flow through heating loop. Reinstalled zone valve head onto body and secured properly. Cycled thermostat to verify proper zone valve operation and confirmed valve closed as designed. System restored to normal operation with zone responding correctly to thermostat calls.