Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 15, 2026.
Hurlburt Heating & Plumbing has completed 3,589 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed comprehensive furnace preventive maintenance on 2-year-old unit, performing thorough inspection and cleaning of all routine components including burners, heat exchanger, blower assembly, and electrical connections. All systems tested and verified operating within manufacturer specifications with no deficiencies noted.
Installed state-approved ASSE 1013 reduced pressure principle backflow preventer to address high hazard cross-connection concerns from laundry detergents and bleach concentrates connected to the potable water system. The RPZ assembly was required to pass cross-connection control inspection and includes brass valves, copper piping, Y-strainer, and test cocks mounted on utility room wall. Device has been registered and will require annual testing by an approved cross-connection control specialist to maintain compliance.
Responded to service call for faucet cartridge replacement. Upon initial assessment, identified fixture as Pfister in-wall ceramic valve system requiring cartridge rebuild. Attempted installation with standard Moen/Delta compatible cartridges, but determined incorrect fitment after opening trim. Removed existing trim to access valve body and confirmed manufacturer specifications. Ordered correct Pfister ceramic valve cartridge (Model: 910-0300) for proper repair completion. Fixture temporarily secured pending arrival of manufacturer-specific replacement parts.
Responded to a main line sewer backup caused by grease and toilet paper buildup located 32-40 feet from the cleanout access point. Cleared the blockage using mechanical drain cleaning equipment, restoring proper flow to the system. Performed video camera inspection of the line to verify complete clearance and confirm no additional obstructions or damage to the pipe.
Responded to kitchen sink faucet leak caused by failed internal cartridges. Diagnosed dual-handle Pfister faucet with worn hot and cold cartridges showing mineral buildup and deteriorated seals. Removed both defective cartridges from valve bodies and installed new Pfister replacement cartridges for hot and cold water lines. Tested both handles for proper operation and verified leak was eliminated. System restored to full functionality.
Responded to no hot water call and found 20-year-old water heater had been disassembled by homeowner in attempted repair. Removed failed unit and installed new 50-gallon natural gas power vent water heater with proper copper piping connections, pressure relief valve, and shut-off valves. Tested system for proper operation and verified hot water delivery throughout residence.
Responded to no heat/cool/fan operation following thermostat replacement. Upon arrival, diagnosed that common wire had been incorrectly terminated during DIY thermostat installation, causing system malfunction. Customer had attempted to correct the wiring but tripped the low voltage fuse in the process. Replaced blown low voltage fuse on furnace control board and verified proper thermostat wiring connections. Tested all system functions including fan operation, cooling mode, and heating mode—all operated correctly. Discussed equipment age and condition with customer, who requested replacement pricing information.
Responded to main line sewer backup caused by toilet paper obstruction located approximately 7 feet from access point. Successfully cleared blockage using mechanical cable equipment, restored proper drainage flow, and performed video camera inspection to verify complete clearance and assess line condition.
Completed comprehensive furnace and AC tune-up on 2-year-old Lennox dual system. Upon arrival, homeowner reported no current operational concerns. Inspected air filter and found it clean but noted high MERV rating that could restrict airflow. Performed thorough inspection of routine components on both furnace and air conditioning unit, with all components measuring within manufacturer specifications. Conducted complete safety inspection on furnace with no compromises identified. Verified all condensate drain lines were clear and draining properly. Ran operational tests on both systems for 15 minutes each to assess performance under load. Furnace achieved 55-degree temperature rise, and air conditioning unit produced 22-degree temperature drop, both within acceptable parameters. Inspected heat exchanger coils and found normal dust accumulation with structural integrity intact. Recommended transitioning to lower MERV-rated filter to optimize airflow and system efficiency. Both systems op
Completed comprehensive maintenance on a five-year-old Lennox two-stage furnace. Verified inducer capacitor functionality, cleaned flame sensor and burners, and inspected hot surface ignitor, blower wheel, thermostat connections, evaporator panel, and condensate drain. All components tested within normal operating parameters with no issues identified. Unit operating efficiently and homeowner enrolled in basic maintenance plan for ongoing service coverage.
Responded to service call for garbage disposal with dish rag lodged inside unit. Upon inspection, confirmed that a rag had been accidentally dropped into the disposal mechanism. Tested disposal operation and verified unit was functioning properly with no mechanical issues or damage. Provided estimate for replacement disposal installation as a preventative option for customer consideration.
Responded to kitchen sink drain stoppage caused by lemon peel lodged in garbage disposal system. Customer had attempted multiple clearing methods without success. Utilized drain auger to successfully clear obstruction from kitchen sink drain line. Verified proper drainage and water flow upon completion. Plumbing system restored to normal operation.
Responded to service call for reported water heater leak in utility space. Upon inspection, discovered standing water in confined crawl area beneath floor with aged plumbing infrastructure showing significant deterioration. Assessed tanked water heater and surrounding plumbing components, including copper piping with compromised insulation and corroded surfaces. Determined primary issue was main drain line blockage under floor or outside building rather than water heater failure. Black waste pipe showed severe insulation degradation with exposed sections, and brass fittings displayed age-related patina and discoloration. Photographed deteriorated conditions including damaged pipe insulation, confined utility space configuration, and affected plumbing components for documentation. Advised customer that standing water resulted from plugged main line causing drainage backup in floor drain rather than water heater malfunction. Scheduled follow-up appointment for professional drain cleaning
Responded to callback for knocking sounds in hot water lines under master bathroom floor. Upon inspection, identified unsupported PEX hot water pipe near vanity causing knocking when faucet activated. Added proper pipe support to eliminate rubbing and reduce noise. Advised homeowner that some residual creaking may occur in floor joists during thermal expansion as pipes heat up, which is normal behavior for the installation.
Responded to emergency call for water throughout basement with unknown source. Upon inspection, determined the issue was a backed-up sewer main rather than a supply line leak. Dispatched specialized drain cleaning equipment to clear the main sewer blockage and restore proper drainage to the property.
Responded to emergency water leak in shower causing damage to basement ceiling below. Upon inspection, identified failed shower cartridge and improperly sealed trim allowing water infiltration through flooring. Documented existing conditions with photographs of basement water heater area showing evidence of water damage and plumbing infrastructure. Provided detailed written estimates for cartridge replacement and proper caulking of shower trim to prevent future water intrusion.
Responded to gas leak call following recent pool heater installation by third-party contractor. Upon inspection, discovered gas union connection improperly secured with electrical tape instead of proper mechanical connection. Removed electrical tape, properly tightened gas union fitting to manufacturer specifications, and performed comprehensive gas leak detection test on all connections. Verified system integrity with no leaks detected and restored safe operation of gas supply line.
Completed comprehensive AC tune-up on Carrier outdoor condensing unit. Performed thorough washing of outdoor unit coils and cabinet, tested all electrical components and connections at disconnect box, and verified proper system operation. Unit found to be functioning correctly with no issues identified during inspection.
Completed comprehensive maintenance agreement service on multiple HVAC systems including central AC, furnace, and six Mitsubishi Electric split-system heat pumps. Performed filter cleaning on all indoor mini-split units and inspected outdoor condensing units, clearing debris and verifying no rodent intrusion. Coordinated follow-up consultation with service advisor regarding potential electric baseboard heater installation as backup heating solution.
Completed comprehensive seasonal maintenance on 2-year-old HVAC system including both heating and cooling components. Performed furnace tune-up with operational testing, cleaned flame sensor, inspected igniter, verified gas pressure within specifications, replaced air filter, and inspected blower motor assembly. Cleared condensate drain lines to ensure proper drainage and prevent overflow. Transitioned system to cooling mode and performed exterior condenser coil cleaning to remove debris and restore optimal airflow. Tested all air conditioning components including compressor, fan motor, and capacitor. Measured temperature differential across evaporator coil confirming adequate system performance. All heating and cooling equipment operating within manufacturer specifications with no deficiencies noted.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.