Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 16, 2026.
Hurlburt Heating & Plumbing has completed 3,589 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed comprehensive preventive maintenance on residential furnace and air conditioning system. Performed thorough inspection of both units, cleaning and checking all routine components including burners, heat exchanger, blower assembly, evaporator coil, condensate drain, electrical connections, and refrigerant levels. All systems tested within manufacturer specifications and operating properly at time of service completion.
Completed comprehensive furnace tune-up on 2023 system following standard maintenance protocol. Following recent gas meter replacement by utility company, verified and confirmed all gas supply pressures were within manufacturer specifications using calibrated testing equipment. All system components inspected and found operating properly with no deficiencies noted.
Responded to clogged toilet with poor flushing performance. Upon inspection, discovered soap bottle lodged in the P-trap causing the obstruction. Removed toilet from floor flange, extracted the foreign object from the trap, and reinstalled toilet with proper seal to restore full functionality.
Responded to no-cooling complaint on 2001 Carrier R-22 air conditioning system experiencing repeat evaporator coil freeze-ups. Upon arrival, confirmed frozen evaporator coil and liquid line set. Performed diagnostic testing and found system operating with only 2.7–3°F subcooling versus manufacturer specification of 13°F after 10-minute run cycle, indicating low refrigerant charge or potential liquid-side metering/restriction issue. Verified air filter was clean and inspected outdoor condenser unit, finding no electrical defects or mechanical issues with condenser components. Documented visible corrosion and weathering on outdoor unit consistent with 20-year-old equipment age. Recommended full refrigerant leak detection, repair evaluation, and recharge to restore proper system operation and prevent continued freeze-up conditions. Additionally recommended pre-season heat exchanger inspection on paired Payne 40-inch furnace with polypropylene-lined secondary heat exchanger due to known is
Responded to water leak complaint affecting interior ceiling and cabinetry. Upon investigation, identified sagging dryer vent as primary source of moisture intrusion rather than HVAC condensation issue. Inspected attic space and confirmed dryer duct had separated from proper pitch, causing condensation accumulation and discharge through finished ceiling, resulting in visible mold growth. Documented conditions with photographs showing moisture on ductwork and structural components. Verified leak source with homeowner and recommended professional mold remediation assessment due to extent of water damage and microbial growth on ceiling surfaces.
Completed comprehensive maintenance on 2004 Nordyne furnace and air conditioning system. Performed full system inspection including heat exchanger evaluation, blower assembly assessment, and refrigerant system diagnostics. Found blower capacitor testing at 4.29 µF on 5 µF rating, inducer motor drawing 1.90 amps versus 1.75 amp nameplate with audible humming indicating bearing wear, and outdoor dual-run capacitor measuring 26.7 µF on 30 µF section. R-22 condenser compressor exhibiting elevated noise levels suggesting potential refrigerant undercharge or internal wear. Cleaned blower wheel and completed all standard maintenance procedures. No immediate safety concerns identified with heat exchanger or system operation. Recommended replacement of both blower and outdoor capacitors due to degraded performance, inducer motor replacement after verifying proper voltage supply and impeller rotation, and monitoring of compressor performance for potential refrigerant charge adjustment or system
Responded to service call for Navien tankless water heater not producing hot water. Removed and replaced clogged cold water inlet filter screen and performed complete system flush to address flow and heating issues. Despite successful completion of inlet screen replacement and thorough flushing procedure, unit continued to exhibit no hot water production, indicating additional component failure requiring further diagnosis and parts replacement on follow-up visit.
Responded to a drainage emergency in a 1941-era home where a deteriorated cast iron waste pipe had dropped approximately 5 inches from its original position, causing complete backup of all drains into the basement. Upon inspection, found the aged cast iron pipe had failed at a joint connection, with visible signs of corrosion and structural compromise. Documented the extent of damage through photographs showing the displaced pipe, surrounding water stains on wooden structural members, and temporary foam sealant material at the floor penetration point. The failed section exhibited significant discoloration and deterioration consistent with 80+ year-old cast iron plumbing. Assessed the existing plumbing configuration, which included a mix of original cast iron, PVC drain lines, and various connecting components mounted to wooden backing. Provided a comprehensive estimate for complete pipe repair and replacement of the compromised cast iron section to restore proper drainage function and
Completed family rewards plumbing inspection at residential property. Removed and replaced aging 1991 model 40-gallon power vent water heater that had reached end of service life. Installed new power vent water heater unit, ensuring proper venting connections and code compliance. Inspected bathroom plumbing fixtures including tub/shower assembly with chrome single-handle faucet, diverter valve, and vanity sink with two-handle centerset faucet in brushed nickel finish. All fixtures found in functional condition with normal wear. Documented installation with photos for service records.
Responded to no heat call on 4-year-old Amana furnace that was running constantly. Diagnosed seized inducer motor preventing proper furnace operation. Replaced failed inducer motor and verified warranty coverage for parts replacement, restoring heat to the system.
Completed comprehensive plumbing inspection on residential property with 20-year-old home featuring recently installed water heater. Adjusted water supply line on toilet to ensure proper fill valve operation and prevent potential leaks or running water issues. Inspected all visible plumbing fixtures including kitchen sink with pull-down faucet and bathroom toilet, verifying proper drainage, water pressure, and fixture functionality throughout the home.
Performed comprehensive HVAC maintenance inspection on 2005 York R-22 air conditioning system and furnace. Discovered severe evaporator coil airflow restriction with approximately 80% blockage, damaged suction line, and refrigerant circuit restriction causing abnormal suction and head pressures. Identified active gas leak at furnace burner orifice and manifold area requiring immediate shutdown for safety. Documented extensive cobweb and debris accumulation in outdoor unit electrical compartment, corroded drain pan and cabinet areas with potential leakage, and aging capacitor with rust on terminal cap. Captured detailed photographs of equipment make, model, and serial numbers as requested, along with electrical components and system condition. Recommended complete system replacement due to equipment age (20 years), obsolete R-22 refrigerant, severely compromised evaporator coil, cabinet corrosion, and critical gas safety concern. Coordinated with homeowners to schedule consultation with
Completed installation of customer-supplied shower bar that was ordered and picked up from Gerhards. The part was on-site and ready for installation upon arrival. Successfully mounted and secured the shower bar fixture, ensuring proper alignment and stability. Installation completed without complications, and all hardware was properly fastened according to manufacturer specifications.
Performed furnace tune-up on single heating unit. Cleaned flame sensor, conducted electrical testing with all measurements within manufacturer specifications. Unit operating properly with brand new filter already installed at time of service.
Completed comprehensive preventive maintenance on both furnace and air conditioning system. Performed full furnace inspection, cleaning, and component checks on 20+ year old unit; advised customer of age-related wear and potential for component failure, though system currently operating within acceptable parameters. Conducted air conditioning maintenance including condenser coil cleaning and electrical diagnostics. Contactor tested within specifications, air filter found clean. Identified failed run capacitor on hermetic compressor circuit reading 24uf against rated 40uf capacity, contributing to 18-degree temperature differential. Replaced dual run capacitor with proper rated replacement. All systems tested and verified operating correctly upon completion. Customer enrolled in maintenance plan for ongoing service coverage.
Responded to no hot water call and found severely corroded tanked water heater actively leaking from top of unit, with extensive water pooling on basement floor. Removed failed water heater and installed new replacement unit. Replaced corroded gas tire fitting above water heater during installation to ensure safe gas connection. System tested and restored to full operation with hot water service confirmed.
Completed comprehensive plumbing inspection for recurring maintenance service. Inspected kitchen sink plumbing including chrome faucet assembly, side sprayer attachment, and drainage system with no immediate concerns noted. Evaluated basement utility area plumbing infrastructure including copper supply lines, shut-off valves with star-handle controls, and flexible connector hoses. Documented condition of exposed piping and valve operation. Identified areas requiring attention and provided estimate for recommended repairs.
Responded to service call for in-floor heating system with suspected stuck valve and unusual hot water issues on a six-year-old IBC boiler. Upon investigation, system was producing excessive noise and releasing significant amounts of water when air bleeding was attempted. Diagnosed failed air valve (Schrader valve) on the expansion tank as the root cause of the problem. Replaced the defective Schrader valve with new component, bled air from the system, and conducted full operational testing to verify proper function. System restored to normal operation with no further issues detected.
Performed scheduled maintenance on Lennox SLP99 furnace as part of maintenance plan agreement. Removed remaining blower-housing shipping bolt left from January installation, cleaned flame sensor, inspected blower wheel for debris and proper operation, and secured all gas and electrical fittings. Verified outdoor intake and exhaust terminations were clear of obstructions following vegetation trimming. Tested S40 thermostat and bypass humidifier controls, confirming normal operation with no faults or operational issues detected. System operating within manufacturer specifications.
Completed comprehensive furnace preventive maintenance on 2-year-old unit, performing thorough inspection and cleaning of all routine components including burners, heat exchanger, blower assembly, and electrical connections. All systems tested and verified operating within manufacturer specifications with no deficiencies noted.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.