Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 17, 2026.
Hurlburt Heating & Plumbing has completed 3,582 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed annual maintenance agreement service on two active HVAC systems including furnace and air conditioning tune-ups. Performed operational testing on main basement furnace, replaced air filter, verified temperature rise within specifications, and identified active leak in collector box causing rust accumulation in combustion compartment along with steam humidifier canister requiring replacement. Inspected upstairs furnace with all components and temperature rise checking out satisfactorily, noted air filter replacement needed but spare not available on-site. Cleaned debris from outdoor condensing units, tested air conditioning operation on both active systems, and confirmed proper operation. Property has three total systems but older Carrier system with electric air handler is not in use. Provided pricing recommendations for steam humidifier canister, collector box replacement, and upstairs air filter replacement.
Completed plumbing inspection and multiple repairs. Diagnosed and replaced defective Kohler cartridge in lower bathroom shower valve due to malfunction. Installed customer-supplied bathroom sink with new faucet and handle assembly to replace broken fixture. Inspected hydronic heating system with multiple zone circulators, copper distribution piping, and associated controls—all components found operating within normal parameters. Documented existing plumbing infrastructure including three-zone circulator pump configuration, gas line routing, and system control panels. All repairs tested and verified for proper operation with no leaks detected.
Responded to service call for grinder pump backup issue. Upon inspection, identified malfunctioning float switch as the cause of pump failure. Replaced defective float switch to restore proper pump operation. Tested system to verify correct cycling and water discharge through existing PVC discharge lines. Prepared estimate for replacement sump basin cover to improve system protection and safety.
Completed preventive maintenance on 6-year-old air conditioning system and 26-year-old furnace per maintenance agreement. During inspection, identified furnace inducer motor and blower motor/capacitor operating out of manufacturer specifications and nearing failure. AC compressor capacitor tested at 40 microfarads against rated 45 microfarads, causing hard starting condition. Due to age and condition of furnace, recommended system replacement rather than component repairs; provided estimate for AC capacitor replacement as interim measure to maintain cooling operation.
Completed scheduled heating maintenance and furnace tune-up as part of preventative maintenance agreement. Performed comprehensive system inspection including burner assembly, heat exchanger, electrical components, control boards, and wiring connections. Verified proper operation of all mechanical and safety components, checked airflow through ductwork and venting system, and documented system condition with interior component photography.
Performed comprehensive tune-up and maintenance on 30-year-old oil furnace system that was experiencing heating issues and emitting a hot or burning smell from vents upon initial startup. Conducted full system inspection, replaced burner nozzle, and performed combustion analysis to ensure proper fuel-to-air ratio and efficient operation. Removed small piece of insulation material that had fallen onto the top of the heat exchanger, which was likely the source of the burning odor. Verified all components of the Beckett oil burner assembly were functioning correctly, checked electrical connections, and confirmed proper operation of the heating system. Unit tested and left in good working order.
Responded to service call for shower leak and clogged sink. Upon inspection, identified leaking shower valve at cartridge port and backed-up downstairs vanity drain with leaking drain assembly. Attempted extraction of old Moen cartridge, but cartridge was seized and would not move. Determined full shower valve replacement necessary. Provided estimates for shower valve replacement and vanity drain repair. Photographed existing conditions showing stained vanity sink with dual-handle faucet and compromised drain assembly, as well as tub/shower access point with exposed valve assembly behind wall. Ordered required parts for valve replacement and scheduled return visit to complete installation upon parts arrival.
Performed scheduled heating maintenance on 2005 Trane high-efficiency furnace. During inspection, discovered two significant crimp cracks at the burner inlets of the left and center primary heat-exchanger cells, presenting a combustion-safety hazard. Additionally identified failing ECM inducer motor. Documented findings with photographs and discussed safety concerns with homeowner, reviewing repair versus replacement options. Homeowner scheduled follow-up appointment with service advisor to evaluate system replacement, noting the air conditioning unit was recently installed within the past two years.
Completed comprehensive furnace tune-up on 4-5 year old gas unit operating within normal parameters. Cleaned flame sensor, performed electrical testing with all readings within manufacturer specifications, verified drainage hoses were clear, and confirmed proper temperature differentials across the heat exchanger. Air filter was found in new condition and required no replacement.
Completed scheduled furnace tune-up with no issues reported by homeowner. Performed comprehensive system inspection, including examination of heat exchanger, burner assembly, and ductwork installation. All components found to be operating within normal parameters and no repairs were required.
Responded to water leak complaint at shower enclosure installed in April with soft, discolored drywall at corner. Performed diagnostic testing by running water at shower door corner, confirming water seepage through door seal. Inspected all plumbing fixtures including shower valve and shower arm to rule out supply line leaks—no issues found with plumbing components. Identified failed seal at shower door corner as source of water intrusion, evidenced by mold growth and moisture damage at wall-to-door junction. Documented conditions with photos showing discoloration and used inspection camera to assess extent of moisture penetration behind wall surfaces. Coordinated with shower door installation company to schedule resealing of compromised door seal to resolve leak issue.
Completed comprehensive preventive maintenance on residential furnace and air conditioning system. Performed thorough inspection of both units, cleaning and checking all routine components including burners, heat exchanger, blower assembly, evaporator coil, condensate drain, electrical connections, and refrigerant levels. All systems tested within manufacturer specifications and operating properly at time of service completion.
Completed comprehensive furnace tune-up on 2023 system following standard maintenance protocol. Following recent gas meter replacement by utility company, verified and confirmed all gas supply pressures were within manufacturer specifications using calibrated testing equipment. All system components inspected and found operating properly with no deficiencies noted.
Responded to clogged toilet with poor flushing performance. Upon inspection, discovered soap bottle lodged in the P-trap causing the obstruction. Removed toilet from floor flange, extracted the foreign object from the trap, and reinstalled toilet with proper seal to restore full functionality.
Responded to no-cooling complaint on 2001 Carrier R-22 air conditioning system experiencing repeat evaporator coil freeze-ups. Upon arrival, confirmed frozen evaporator coil and liquid line set. Performed diagnostic testing and found system operating with only 2.7–3°F subcooling versus manufacturer specification of 13°F after 10-minute run cycle, indicating low refrigerant charge or potential liquid-side metering/restriction issue. Verified air filter was clean and inspected outdoor condenser unit, finding no electrical defects or mechanical issues with condenser components. Documented visible corrosion and weathering on outdoor unit consistent with 20-year-old equipment age. Recommended full refrigerant leak detection, repair evaluation, and recharge to restore proper system operation and prevent continued freeze-up conditions. Additionally recommended pre-season heat exchanger inspection on paired Payne 40-inch furnace with polypropylene-lined secondary heat exchanger due to known is
Responded to water leak complaint affecting interior ceiling and cabinetry. Upon investigation, identified sagging dryer vent as primary source of moisture intrusion rather than HVAC condensation issue. Inspected attic space and confirmed dryer duct had separated from proper pitch, causing condensation accumulation and discharge through finished ceiling, resulting in visible mold growth. Documented conditions with photographs showing moisture on ductwork and structural components. Verified leak source with homeowner and recommended professional mold remediation assessment due to extent of water damage and microbial growth on ceiling surfaces.
Completed comprehensive maintenance on 2004 Nordyne furnace and air conditioning system. Performed full system inspection including heat exchanger evaluation, blower assembly assessment, and refrigerant system diagnostics. Found blower capacitor testing at 4.29 µF on 5 µF rating, inducer motor drawing 1.90 amps versus 1.75 amp nameplate with audible humming indicating bearing wear, and outdoor dual-run capacitor measuring 26.7 µF on 30 µF section. R-22 condenser compressor exhibiting elevated noise levels suggesting potential refrigerant undercharge or internal wear. Cleaned blower wheel and completed all standard maintenance procedures. No immediate safety concerns identified with heat exchanger or system operation. Recommended replacement of both blower and outdoor capacitors due to degraded performance, inducer motor replacement after verifying proper voltage supply and impeller rotation, and monitoring of compressor performance for potential refrigerant charge adjustment or system
Responded to service call for Navien tankless water heater not producing hot water. Removed and replaced clogged cold water inlet filter screen and performed complete system flush to address flow and heating issues. Despite successful completion of inlet screen replacement and thorough flushing procedure, unit continued to exhibit no hot water production, indicating additional component failure requiring further diagnosis and parts replacement on follow-up visit.
Responded to a drainage emergency in a 1941-era home where a deteriorated cast iron waste pipe had dropped approximately 5 inches from its original position, causing complete backup of all drains into the basement. Upon inspection, found the aged cast iron pipe had failed at a joint connection, with visible signs of corrosion and structural compromise. Documented the extent of damage through photographs showing the displaced pipe, surrounding water stains on wooden structural members, and temporary foam sealant material at the floor penetration point. The failed section exhibited significant discoloration and deterioration consistent with 80+ year-old cast iron plumbing. Assessed the existing plumbing configuration, which included a mix of original cast iron, PVC drain lines, and various connecting components mounted to wooden backing. Provided a comprehensive estimate for complete pipe repair and replacement of the compromised cast iron section to restore proper drainage function and
Completed family rewards plumbing inspection at residential property. Removed and replaced aging 1991 model 40-gallon power vent water heater that had reached end of service life. Installed new power vent water heater unit, ensuring proper venting connections and code compliance. Inspected bathroom plumbing fixtures including tub/shower assembly with chrome single-handle faucet, diverter valve, and vanity sink with two-handle centerset faucet in brushed nickel finish. All fixtures found in functional condition with normal wear. Documented installation with photos for service records.