Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 18, 2026.
Hurlburt Heating & Plumbing has completed 3,571 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed scheduled heating maintenance on 3-year-old Lennox HVAC system. Performed comprehensive furnace tune-up including inspection of air handler unit, verification of all mechanical components, and testing of system operation. Unit found to be functioning properly with no issues identified. All maintenance tasks completed per agreement specifications.
Responded to water backup issue affecting two toilets that were not flushing properly due to accumulation of toilet paper and debris in the main sewer line. Performed main line cleanout, conducted camera inspection to assess line condition, removed and reset one toilet to access the drain system, and ground out the deteriorated cleanout plug before installing a new plug to ensure proper future access for maintenance.
Completed HVAC install callback to address air sealing and hardware issues. Replaced broken furnace door clip with new latch to ensure proper cabinet closure. Sealed gaps around A-coil box and connected ductwork to eliminate air leakage. Installed hold-down clamp on AC condensate drain hose to secure drain line and prevent disconnection.
Completed scheduled heating maintenance and furnace tune-up on two 2-year-old Lennox HVAC systems as part of routine preventive maintenance agreement. Performed comprehensive inspection and maintenance procedures on both units, confirming all systems are operating within normal parameters with no issues identified. Documentation photos captured showing equipment condition and company service sticker placement.
Completed routine maintenance on 5-year-old Lennox furnace unit under maintenance agreement. Cleaned routine components, performed full system inspection, monitored furnace operation at 100% fire rate to verify proper combustion and heat output, and tested humidifier functionality to ensure proper operation. All systems operating within normal parameters with no issues identified.
Installed thermal expansion tank on residential tanked water heater to comply with Wisconsin plumbing code requirements. The home is equipped with a pressure reduction valve, which necessitates proper thermal expansion management. Static water pressure measured at 80 psi; expansion tank pre-charged to 78 psi to match system specifications. All connections secured with appropriate PVC and flexible metallic piping, red-handled isolation valve installed for future serviceability. System tested and verified operational with existing whole house water filtration equipment.
Responded to service call for blower motor replacement. Upon inspection, determined the initially sourced replacement motor was incompatible with the existing system. Coordinated with parts department to locate compatible motor at supplier location, arranged for overnight delivery to shop, and scheduled installation for the following day with customer approval for the revised timeframe.
Completed installation and connection of commercial bar sink with drain assembly. Connected two separate drain lines to stainless steel basin, ensuring proper fit of brass drain fittings and verifying secure connections throughout the system. All plumbing connections tested and confirmed operational for commercial use.
Responded to no-heat callback on recently installed furnace. Upon inspection, discovered both the external gas shutoff valve and the furnace gas valve switch were in the OFF position. Restored gas supply at both locations and verified normal heating operation. Unit produced significant startup smoke upon initial firing, activating smoke alarms, indicating residual manufacturing oils or possible lack of operational verification during original installation. Documented control board wiring and external gas meter assembly. System now operating normally with proper heat output.
Completed full-system maintenance on 7-year-old Bryant 926TB60100V21A-B furnace and Bryant 127ANA036-B 3-ton single-stage condenser. Inspected heat exchanger coating condition and verified proper operation of both units. Identified Ecobee thermostat configuration error showing Cool 2 call on single-stage condenser; corrected settings to 2-stage heat / 1-stage cool with no Y2 cooling call to match equipment capabilities. Measured subcooling at 9.5°F against rated 14°F specification with dirty filter in place at 73°F outdoor and 72°F indoor temperatures. Addressed conflicting thermostat temperature settings between Auto and AC-only modes and discussed proximity of thermostat to sensor affecting system operation. Evaluated aged Honeywell HZ322 UV system with bulb unreplaced since 2020; advised of potential bulb breakage during removal due to age and recommended replacement options including alternate base or complete UV system upgrade. Coordinated follow-up for filter replacement pricing
Completed scheduled furnace tune-up on 2-year-old unit per maintenance agreement. Accessed property through rear gate with homeowner permission and performed comprehensive inspection and maintenance of all furnace components. All systems tested and confirmed operating within proper parameters; unit functioning correctly with no issues identified.
Completed comprehensive furnace preventive maintenance and safety inspection on American Standard heating system. Performed thorough cleaning of all routine components including burner assembly, heat exchanger, and blower compartment. Conducted complete operational testing of ignition system, gas valve, flame sensor, and safety controls. Verified proper airflow, checked and adjusted blower motor operation, and inspected ductwork connections. All components found to be functioning within normal parameters with no deficiencies noted. System operating safely and efficiently at time of service completion.
Completed comprehensive furnace tune-up and maintenance on residential HVAC system. Discovered and removed dead rodents (bats and mouse) from unit interior and identified deteriorated return ductwork in basement area caused by moisture damage from water exposure at front door return vent. Cleaned accumulated rust particles and debris from affected components, verified all mechanical and electrical systems functioning properly, and confirmed proper burner operation and airflow throughout system.
Completed comprehensive preventive maintenance on both air conditioning and furnace systems. Performed full tune-up procedures on Bryant outdoor condensing unit and indoor heating system, including inspection of electrical components, airflow verification, and operational testing. All equipment operating within normal parameters with no deficiencies noted at time of service.
Performed furnace maintenance tune-up on aging system. Upon powering up the unit, furnace immediately faulted with two-flash code indicating pressure switch stuck closed or inducer error. Conducted comprehensive troubleshooting of all safety switches and wiring connections. Isolated issue to thermostat circuit by removing thermostat wire from control board and jumping R to W terminals, which resulted in normal system operation. Bypassed RDS board by removing wires and connecting them directly to furnace terminals with wire nuts, restoring proper function. Captured video documentation of system operation after completing tune-up process. Recommended homeowner contact original installation company to verify proper wiring configuration and replace current thermostat to prevent future operational issues.
Responded to leaking laundry connections where outdated shower shutoff valves were failing at the hot and cold water supply lines for the washing machine. Removed the old defective valves and installed new boiler drains to provide reliable shutoff capability and eliminate the active leaks. System was tested and confirmed operational with no further leakage detected.
Completed scheduled heating maintenance and furnace tune-up per maintenance agreement. Performed comprehensive inspection of furnace unit, including internal components, burner assembly, gas valves, heat exchanger, ignition system, electrical connections, and wiring. Verified proper operation of all mechanical systems and confirmed unit is functioning correctly with no issues identified.
Completed annual maintenance agreement service on two active HVAC systems including furnace and air conditioning tune-ups. Performed operational testing on main basement furnace, replaced air filter, verified temperature rise within specifications, and identified active leak in collector box causing rust accumulation in combustion compartment along with steam humidifier canister requiring replacement. Inspected upstairs furnace with all components and temperature rise checking out satisfactorily, noted air filter replacement needed but spare not available on-site. Cleaned debris from outdoor condensing units, tested air conditioning operation on both active systems, and confirmed proper operation. Property has three total systems but older Carrier system with electric air handler is not in use. Provided pricing recommendations for steam humidifier canister, collector box replacement, and upstairs air filter replacement.
Completed plumbing inspection and multiple repairs. Diagnosed and replaced defective Kohler cartridge in lower bathroom shower valve due to malfunction. Installed customer-supplied bathroom sink with new faucet and handle assembly to replace broken fixture. Inspected hydronic heating system with multiple zone circulators, copper distribution piping, and associated controls—all components found operating within normal parameters. Documented existing plumbing infrastructure including three-zone circulator pump configuration, gas line routing, and system control panels. All repairs tested and verified for proper operation with no leaks detected.
Responded to service call for grinder pump backup issue. Upon inspection, identified malfunctioning float switch as the cause of pump failure. Replaced defective float switch to restore proper pump operation. Tested system to verify correct cycling and water discharge through existing PVC discharge lines. Prepared estimate for replacement sump basin cover to improve system protection and safety.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.