Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 24, 2026.
Hurlburt Heating & Plumbing has completed 3,564 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Completed phone follow-up regarding estimate discussion. Documented site conditions with photographs showing roadway access and property location for reference. Customer contact established to address estimate questions and provide requested information.
Performed second opinion inspection on Lennox G32Q3-75-3 75,000 BTUH natural gas furnace following previous contractor's diagnosis of heat exchanger failure. Conducted thorough visual examination and confirmed presence of through-crack in left primary heat exchanger cell, consistent with prior findings from previous technician visit. Documented crack with photographic evidence showing compromised heat exchanger creating potential combustion gas and carbon monoxide safety hazard. Tagged furnace as unsafe for operation due to verified heat exchanger breach that allows products of combustion to enter conditioned air stream. Explained safety concerns to homeowner regarding immediate carbon monoxide exposure risk. Homeowner declined recommendation to keep unit disabled and insisted on furnace reactivation despite documented safety hazard. Contacted emergency services to ensure occupant safety given the dangerous operating condition and homeowner's decision to continue furnace use against pr
Completed preventative maintenance on an 11-year-old Bryant gas furnace system. Performed comprehensive tune-up procedures, confirmed unit operating within proper parameters, and replaced the humidifier pad with customer-supplied media to ensure optimal humidity control for the heating season.
Responded to service call for 3-year-old gas water heater exhibiting corrosion on top of unit and melted plastic caps from previous backdrafting issue. Inspected A.O. Smith ProLine water heater and confirmed cosmetic damage to plastic caps with evidence of prior negative pressure problems. Cleaned corrosion residue from backdrafting on top of tank and replaced nine melted plastic caps. Advised that plastic caps serve cosmetic purposes only and verified that HVAC contractor had previously addressed and resolved the negative pressure issue causing the backdrafting condition. Unit operational with proper venting function restored.
Completed gas piping repair on Carrier furnace system and performed comprehensive pressure testing of entire gas line. Conducted air test to verify system integrity and leak-free connections. System now awaiting final inspection for approval to restore gas service.
Responded to upstairs bathroom sink backup. Removed drain stopper and cleared hair accumulation from drain assembly. Plugged overflow opening and attempted plunging with no success. Disassembled P-trap beneath sink to inspect for obstruction—trap was clear, indicating blockage located further downstream in branch line. Cleaned accessible drain components and reassembled trap assembly. Performed camera inspection of main sewer line to assess overall drainage system condition and identify potential issues in the building's waste piping. Blockage in pipe was located and cleared. System restored to proper drainage function.
Responded to a no-heat call and diagnosed a Goodman two-stage furnace with a failed, locked-up inducer motor. Inspected the inducer housing and confirmed it was clear of debris and animal intrusion. Identified a leaking collector box with three stripped mounting screws on the lower/left side that will require attention. Noted the existing Carrier air conditioning unit was manufactured in 1992 and documented system conditions with photographs of the ductwork and evaporator coil for the homeowner's review of replacement options.
Performed comprehensive maintenance on 15-year-old heating and cooling systems including boiler and air conditioning unit. Cleaned outdoor condenser unit, flushed indoor condensate drain lines, and inspected all electrical connections and components for proper operation. Conducted operational tests on both heating and cooling modes to verify system performance and confirm all equipment functioning within normal parameters.
Completed annual tuneup on both air conditioning and furnace systems. Performed comprehensive inspection of Lennox outdoor condenser unit and indoor furnace with condensate pump assembly. Verified all electrical components on both systems tested within manufacturer specifications. Confirmed air filters were clean and both units operating properly at time of service.
Installed a whole home carbon water filtration system with blue cap housing, mounting brackets, and white PVC supply piping to main water line. Added thermal expansion tank to water heating system to comply with Wisconsin Administrative Code SPA 382.40(3)(c)4, as existing pressure reducer on main line created a closed-loop system without proper expansion protection. Connected expansion tank with appropriate PVC piping and brass fittings, securing unit to wall framing adjacent to water heater. All installations completed per approved estimate with proper mounting, connections, and shutoff valves for future maintenance access.
Completed comprehensive furnace maintenance on a 3-year-old system in preparation for extended seasonal absence. Performed standard tune-up procedures including blower wheel inspection and combustion analysis using calibrated flue gas analyzer, which confirmed optimal performance with oxygen levels at 9.0%, carbon monoxide at 8 ppm, and carbon dioxide at 6.73%. System is operating within manufacturer specifications with no deficiencies noted at this time.
Responded to emergency call for toilet leaking through ceiling into kitchen below. Upon inspection, identified failed wax ring as source of leak. Removed toilet and assessed flange condition—cast iron flange found to be structurally sound with no replacement required at this time. Installed new wax ring, properly reset toilet to ensure proper seal, and applied caulking along front base for added stability. Advised property owner that future leak issues may necessitate flange replacement and subfloor repair due to age of existing components.
Responded to commercial facility at school entrance for non-operational garbage disposal and leaking toilets in bathroom stalls. Found the disposal's hard reset button had tripped. Performed reset procedure, inspected trap for obstructions, and tested unit to confirm proper operation. Assessed two commercial-grade toilets requiring vacuum breaker installation and repairs for active leaks. Completed part order documentation to provide repair estimate for toilet fixtures. Photographed drain assembly and plumbing components for service records.
Completed scheduled furnace maintenance on residential heating system. Performed comprehensive inspection including heat exchanger scope examination with no issues found, cleaned flame sensor which tested at 3.5 microamps after service, and verified all electrical components operating within manufacturer specifications with unit functioning properly upon completion.
Responded to a toilet repair call and diagnosed a malfunctioning flush valve and deteriorated supply valve. Removed the old components and installed a new flush valve assembly and supply valve, restoring proper flushing operation and eliminating leaks. Tested the system to confirm proper water flow and tank refill functionality.
Responded to service call for wood stove disconnection due to homeowners insurance coverage complications. Successfully unplugged electrical connection and disconnected chimney pipe from black wood-burning stove unit located in basement utility area. Advised customer that complete sealing of the chimney penetration would require return visit with 7-inch chimney cap and appropriate silicone sealant materials, with estimate to follow from parts department for required components and installation.
Completed comprehensive furnace maintenance on an 18+ year old Goodman unit rated at 70,000 BTU serving approximately 1,000 square feet of conditioned space. Performed standard tune-up procedures including inspection of heat exchanger, which showed no signs of cracking or deterioration. System is significantly oversized for the application with a 14x20 return air configuration. All components are functioning properly with no immediate concerns identified. Recommended duct cleaning services and comfort assessment due to system oversizing affecting efficiency and comfort delivery.
Replaced thermostatic expansion valve (TXV) on residential air conditioning system under parts warranty. After installation, performed pressure test to verify system integrity, evacuated system to proper vacuum levels, recharged refrigerant to manufacturer specifications, and monitored system operation to confirm proper function. Repair successfully resolved abnormal screeching noise complaint and restored unit to normal operating condition.
Performed heat exchanger inspection on Trane furnace installed in 2020 following reports of potential cracking. Verified existing crimp crack in heat exchanger has not propagated beyond the crimped area and remains stable at this time. Documented current condition with photographs for future comparison. Strongly recommended installation of carbon monoxide detectors as a safety precaution and advised scheduling follow-up inspection in spring to monitor heat exchanger condition for any progression of the existing crack.
Responded to no hot water complaint at residential property. Upon inspection, found existing tanked water heater would not maintain ignition and blower motor exhibited severe mechanical failure with loud screeching noise. Unit age was unknown as occupants had recently moved into the property. Due to failed blower motor and ignition issues rendering the water heater inoperable, performed complete water heater replacement. Removed old unit and installed new tanked water heater with proper venting system to ensure safe exhaust of combustion gases and adequate air supply for burner operation.