Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 26, 2026.
Hurlburt Heating & Plumbing has completed 3,564 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to no hot water complaint on a 2-year-old AO Smith water heater that would not ignite. Upon inspection, discovered the thermopile wire was burnt through, preventing the pilot from staying lit. Removed and documented the damaged thermopile assembly for warranty claim processing and scheduled return visit to install replacement thermopile under manufacturer warranty coverage.
Completed heating tune-up on 20-year-old furnace and inspected 20-year-old AC system. Furnace appears functional but unable to perform heat exchanger camera inspection due to equipment malfunction. Provided homeowner instruction on humidifier operation and water panel replacement procedures. Evaluated AC unit that had failed to maintain setpoint on recent warm days; found R-22 refrigerant charge slightly low. Customer elected to defer AC repair until spring season.
Completed comprehensive furnace tune-up and safety inspection on Unit 2 as part of annual maintenance agreement. Performed full system diagnostics, cleaned and inspected all components per manufacturer specifications, and verified proper operation with a 55° temperature rise across the heat exchanger. All systems tested and found operating within normal parameters with no concerns identified.
Responded to no heat call on Bryant furnace less than 10 years old. Performed comprehensive inspection including heat exchanger examination and component evaluation. Identified issue requiring repair and provided detailed repair options; customer elected to defer service decision for further consideration.
Performed comprehensive oil furnace maintenance including replacement of oil nozzle, oil filter, and air filter per customer request. Upon completion, ran full system diagnostics and monitored equipment operations to verify proper functionality. System components showed signs of dust accumulation and aging, with visible oxidation on metal surfaces and discoloration on copper refrigerant lines, though all equipment tested within normal operating parameters.
Responded to no heat call on Coleman-Evcon gas furnace over 20 years old. Upon inspection, found blower motor would not run consistently and had leaked oil. Diagnosed failed run capacitor as primary cause of intermittent blower operation. Verified heat exchanger integrity with no cracks or damage detected. Replaced failed run capacitor and blower motor to restore proper system operation. System tested successfully with blower running continuously and heat functioning normally.
Completed comprehensive furnace and air conditioning tune-up on 8-year-old HVAC system per maintenance agreement protocol. Performed full furnace inspection and tuneup procedures with all specifications documented on tuneup form. Discovered UV bulb in practically burnt-out condition requiring replacement. Tested furnace operation with 15-minute runtime verification, confirming normal operation with 50° temperature rise across heat exchanger. Recommended estimate for UV bulb replacement, which was approved for follow-up. All systems operating within normal parameters at completion.
Completed scheduled furnace tune-up maintenance as part of annual heating system agreement. Performed comprehensive inspection and testing per maintenance protocol, including all safety checks and operational specifications. System tested and ran for 15 minutes with temperature rise measuring 45-50 degrees, confirming proper operation with no issues found.
Completed annual furnace preventive maintenance on 16-year-old HVAC system. Performed comprehensive inspection of all routine components including blower assembly, heat exchanger, burners, electrical connections, and control board. Cleaned burner assembly and verified proper flame characteristics. Inspected ductwork and condensate drain lines for proper operation. All components tested within manufacturer specifications and system operating normally at time of service completion.
Responded to a water leak in the basement near the washer and HVAC system. Upon inspection, identified severely corroded shut-off valves and hammer arrestors as the source of the leak, which had been causing water accumulation on the floor for several weeks. Removed and replaced all corroded valves and hammer arrestors with new components to eliminate the leak and restore proper water flow control.
Installed Taco check valve in heating system pump to resolve heat leaching issue. Verified proper operation of check valve and confirmed elimination of unwanted heat transfer through the system. All components tested and functioning correctly upon completion.
Responded to no heat call on 2017 gas furnace. Upon inspection, discovered gas valve sticking and impeding operation; temporarily freed valve to restore function. Conducted comprehensive safety inspection and heat exchanger evaluation, revealing multiple holes and compromises in primary heat exchanger. All other routine components tested within normal specifications. Due to cracked heat exchanger presenting carbon monoxide hazard, unit was red-tagged and taken out of service per safety protocols. Documented findings with photographs showing deteriorated heat exchanger surfaces with visible perforations and rust damage. Explained safety concerns and equipment condition on-site, recommended replacement options versus repair given age of unit and extent of heat exchanger failure.
Completed comprehensive furnace tune-up and heating system inspection on Lennox residential unit. Performed full preventive maintenance protocol including burner inspection, heat exchanger examination, blower motor assessment, and safety control verification. All components found operating within manufacturer specifications with no deficiencies noted.
Completed routine furnace maintenance on 15-year-old Trane unit as part of membership agreement. All routine components tested within specification, system operated normally with 55° temperature rise during 15-minute operational test. Safety inspection revealed heat exchanger burner inlet showing early stage cracks not yet extending past riveting, and secondary heat exchanger displaying early signs of condensation leaking. While no immediate safety concern exists at this time, heat exchanger condition warrants monitoring and future replacement consideration. Recommended follow-up discussion regarding system condition and replacement pricing options.
Responded to a main sewer line backup affecting the basement. The blockage was located approximately 26 feet into the line and extended further downstream. Successfully cleared the obstruction using professional drain cleaning equipment, restored proper flow, and performed a video camera inspection to verify the line was fully operational and assess overall condition.
Performed comprehensive furnace tune-up on Arcoaire unit, including cleaning of routine components, testing all operational systems, and monitoring equipment performance to ensure proper functionality. All components inspected and confirmed operating within normal parameters.
Responded to no heat call with reported gurgling water sounds from furnace. Upon inspection, found inducer assembly completely flooded with water and severe corrosion present, including one mounting screw rusted through and snapped off. Observed extensive rust damage beneath inducer and on burner assembly. Performed video scope inspection of heat exchanger and identified multiple breach points indicating heat exchanger failure. Due to safety concerns, shut down furnace completely by unplugging inducer motor and igniter, closing gas valve at appliance and main gas shutoff. Left blower operational for air circulation. Provided repair estimates and scheduled appointment for replacement system consultation. Unit photographed for documentation.
Responded to no cooling call on 12-year-old R22 system that had been physically damaged when a lawn fertilizer company vehicle backed into the outdoor unit, pushing it against the exterior wall and causing visible kinking in the refrigerant line-set. Upon arrival, confirmed system was completely empty of R22 refrigerant due to the damage. Performed static pressure measurements before and after the filter cabinet to verify airflow system integrity. Explained repair options including R22 leak repair versus system replacement considerations given the age of the equipment and current refrigerant costs, but customer declined repair estimates and opted to consider replacement options only.
Completed comprehensive seasonal maintenance on both air conditioning and furnace systems per maintenance agreement. Performed full tune-up procedures on Lennox outdoor condensing unit and indoor furnace equipment. Inspected all electrical connections, tested system operations, and verified proper functionality of both heating and cooling systems. All equipment operating within manufacturer specifications with no deficiencies noted. Routine maintenance service completed successfully.
Responded to no heat call on 25-year-old furnace experiencing short cycling issues. Upon arrival, customer reported unit would ignite briefly then shut off immediately. Diagnosed faulty pressure switch that was not closing properly during ignition sequence, despite inducer motor pulling adequate vacuum. During inspection, identified blower capacitor reading out of specification and excessive play in blower wheel bearings indicating imminent failure. Completed comprehensive safety inspection with no additional compromises found. Provided estimates for immediate pressure switch replacement and future blower motor assembly replacement due to age and condition of unit. Part orders submitted and follow-up service scheduled for Tuesday.