Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.

Heating calls in Eau Claire come with a wide mix of systems because the city has homes from nearly every era. Older neighborhoods like East Hill and Third Ward still have boiler systems, radiant heat, and homes that were never originally designed for central air. Meanwhile, many mid-century homes throughout Eau Claire still rely on aging forced-air furnaces that struggle to keep up during long Wisconsin winters.
We see a lot of airflow issues, aging heat exchangers, undersized ductwork, and systems that have simply reached the end of their lifespan. During sub-zero stretches, those problems become obvious fast.
Eau Claire summers can get surprisingly humid, especially near the Chippewa River and lower areas around Half Moon Lake. That humidity puts extra strain on older AC systems, particularly in homes that were not originally built with central air.
We work on a lot of mid-century homes where the ductwork was designed for heating first and cooling second. That often leads to uneven temperatures, weak airflow upstairs, and systems that cannot keep up during July heat waves.
Plumbing problems in Eau Claire often come down to age, freezing temperatures, and older infrastructure. Homes in older parts of the city can still have aging drain lines, outdated water piping, or plumbing systems that have been patched together over several decades.
During Wisconsin winters, frozen pipes and sump pump failures become common calls, especially during freeze-thaw cycles. We also see a steady demand for water softeners and water filtration systems throughout the Eau Claire area.
Older Eau Claire homes often have tight mechanical spaces and aging plumbing layouts that require experience to service properly.
If you are dealing with leaks, drain backups, or sump pump problems, we can help, call (715) 227-4145 today or connect with Hurlburt online to schedule service.
Electrical systems across Eau Claire vary just as much as the housing stock itself. Some older homes still operate on outdated panels that were never designed for modern electrical demand. We regularly see overloaded circuits, insufficient panel capacity, and aging wiring in homes built before the 1970s.
At the same time, newer neighborhoods are adding EV chargers, smart home systems, generators, and additional electrical loads that require upgraded infrastructure.
The dry winters and humid summers in Eau Claire create year-round indoor air quality challenges. During the winter, many homes become extremely dry once the furnace runs constantly. In the summer, excess humidity can leave the house feeling sticky even when the AC is operating.
A lot of homeowners also deal with dust buildup, pet dander, and poor airflow, especially in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference throughout the year. Call (715) 227-4145 today or connect with Hurlburt online to improve your comfort.
We are already working throughout Eau Claire every single day. This is not a secondary service market for us. It is where our company has operated for generations.
You have likely seen us at the Chippewa Valley Home Show, sponsoring the Fairfax Pool or Hobbs Ice Arena, or on WEAU 13 News during the Morning Connection segments where we share seasonal homeowner tips.
Hurlburt Heating & Plumbing has completed 20 jobs in Eau Claire, WI in September 2026.
The most recent job was on September 29, 2026.
Hurlburt Heating & Plumbing has completed 3,564 jobs in Eau Claire, WI in the last 12 months. The first job there was in October 2015.
Responded to service call for continuously running toilet with no tank refill and low water pressure in upstairs shower. Upon inspection, identified failed flapper valve as cause of constant water flow. Replaced defective flapper to restore proper tank function and eliminate water waste. Investigated low pressure complaint at upstairs shower and found cartridge heavily packed with sediment, likely resulting from recent municipal water main work in the area. Removed and cleaned shower cartridge, clearing all debris to restore normal water pressure and flow rate.
Responded to gas leak emergency at residential property where utility company had shut off gas supply and marked leak location at exterior meter elbow on southeast side of structure. Upon arrival, coordinated access through designated contact and conducted thorough inspection of exterior gas supply system and meter assembly. Identified locked gas meter and discovered multiple leak points beyond the initially marked elbow connection, requiring comprehensive assessment of the gas piping system. Documented all findings with photographic evidence showing exterior meter installation with corroded piping, connections, and fittings, as well as interior Richmond water heater and associated gas appliances. Determined that air pressure testing of the entire gas supply line system would be necessary to accurately identify all leak locations and assess the full extent of required repairs. Communicated findings to property owner by phone for approval to proceed with diagnostic air testing and provi
Responded to install follow-up call for recently installed furnace that failed to start. Found gas supply valve in closed position, preventing unit operation. Opened gas valve and verified proper system startup and operation with no additional issues detected.
Replaced Honeywell steam humidifier canister and collector box/cold end header box on residential HVAC system. Installed new cold header assembly and steam humidifier filter, verified all electrical connections to blower motor assembly, and confirmed gas burner operation. System tested and operating within normal parameters upon completion.
Performed comprehensive furnace tune-up and system inspection. Unit operational at time of service. Testing revealed blower capacitor reading 11.2/12.5 microfarads, which is out of manufacturer specifications. Recommended blower capacitor replacement to prevent potential system failure and ensure optimal performance.
Responded to service call for toilet replacement estimate. Assessed existing standard residential toilet in bathroom with small square tile flooring. Evaluated installation requirements and provided written estimate for replacement with new ADA-compliant toilet fixture, including documentation with photographs of current conditions and plumbing connections.
Responded to callback for intermittent low water pressure issue following previous installation. Diagnosed faulty pressure switch that was sticking and causing water supply to shut off intermittently. Tested system pressure and confirmed pressure switch malfunction. Removed defective pressure switch and installed new replacement unit. Verified proper system operation and restored consistent water pressure throughout property.
Conducted site assessment of commercial restroom facilities to evaluate plumbing issues and provide repair estimates. Inspected leaking urinal and toilet flush valve in converted female restroom, recommending replacement of two flush valve assemblies. Evaluated two wall-mounted sinks with seized cold water handles on widespread faucet installations, determining that complete faucet replacement would be necessary due to operational difficulty. Provided complimentary estimates for installation of two new flush valves and four new widespread faucets with chrome finish to restore proper function to commercial bathroom fixtures.
Completed furnace tune-up on 12-year-old residential heating unit. System operational with normal performance parameters. Identified two code violations requiring correction: high voltage wiring terminated with wire nuts and left unsecured inside cabinet, and flexible metal gas connector improperly installed directly to gas valve without proper fittings. Documented conditions with photos and provided estimate for code compliance repairs including proper junction box installation and gas line correction with appropriate connectors and fittings.
Responded to install callback to address missing electrical grounding on furnace and CSST gas line. Installed proper bonding for yellow corrugated stainless steel tubing (CSST) gas line per code requirements to protect against electrical hazards and lightning strikes. Verified grounding connection from electrical panel to gas piping system and confirmed furnace now has appropriate ground wire installation. All work completed and system verified safe for operation.
Completed return visit to install replacement thermopile on A.O. Smith ProMax standard vent water heater. The thermopile had been previously identified as defective during initial diagnostic visit and was replaced under warranty coverage. Installation was completed successfully, restoring proper pilot flame sensing and thermocouple functionality to the unit.
Completed comprehensive furnace tune-up on Lennox unit in basement utility room. Upon arrival, homeowner reported no current concerns with system operation. Performed full maintenance protocol including inspection of all components, replaced air filter with customer-supplied unit, and conducted operational testing. System ran for 15 minutes during testing phase and demonstrated proper performance with a 55-degree temperature rise across the heat exchanger. All components operated within normal parameters. Discussed findings with homeowner and recommended continuing routine maintenance schedule to ensure optimal system performance and longevity.
Responded to service call to inspect cast iron toilet flange prior to new toilet installation. Upon arrival, performed thorough visual examination of the existing cast iron flange and surrounding floor area. Despite visible surface corrosion and oxidation on the metal components, structural inspection confirmed the flange remains structurally sound with no cracks, breaks, or significant deterioration that would compromise its function. Mounting holes intact and flange properly secured to floor. Verified flange is suitable for supporting new toilet installation. Documented existing condition with photographs and advised customer that flange does not require replacement at this time and is adequate for proceeding with toilet installation.
Completed comprehensive furnace tune-up and preventative maintenance inspection on forced air heating system. Performed standard maintenance protocol including filter inspection, burner assembly cleaning, heat exchanger examination, blower motor lubrication, thermostat calibration, and safety control verification. All components found operating within normal parameters with no immediate repairs required.
Responded to no hot water complaint at residential property. Upon arrival, diagnosed 6-year-old Richmond model 6GR40PVEZ-40 gas water heater producing only warm water. Unit displayed error code indicating faulty flammable vapor sensor (FVS). Performed diagnostic testing to confirm sensor malfunction preventing proper burner operation. Documented unit specifications and serial number for parts pricing. Photographed water heater installation, manufacturer data plate, and warning labels for service records. Presented replacement options to customer and provided estimate for new water heater installation. Customer requested additional pricing for repair parts to restore current unit to operation rather than full replacement. Awaiting customer decision on repair versus replacement before proceeding with corrective action.
Completed scheduled heating maintenance on dual-zone Lennox HVAC system as part of annual tune-up agreement. Replaced furnace and humidifier filters on both units with customer-provided filters, performed electrical testing on all components, and cleaned flame sensors to ensure proper operation. Both heating units tested and operating within manufacturer specifications with no issues found.
Responded to an active water leak originating from the dishwasher area that was dripping into the basement and coming into contact with electrical wiring. Upon investigation, determined that the dishwasher only leaked during operation, with water pouring from the housing unit. Identified the issue as an appliance malfunction rather than a plumbing system failure. Documented the plumbing infrastructure and HVAC components in the affected basement area. Advised homeowner to contact an appliance repair specialist to address the dishwasher defect, as the unit is only two years old and the leak is isolated to the appliance itself rather than the home's plumbing system.
Responded to callback for loose toilet seat on recently installed toilet. Upon inspection, discovered right side locking mechanism was not fully engaged. Removed toilet seat, verified bolt tightness, reinstalled seat ensuring both locking mechanisms were properly secured, and performed pull test to confirm stability. Customer advised that alternative seat options are available if issue recurs.
Responded to no heat call on 3-year-old Lennox furnace. Found rollout switch tripped due to spider web obstruction in burner assembly. Cleaned all burners, removed debris, and reset rollout switch. System tested and restored to normal operation with proper ignition and flame characteristics confirmed.
Responded to bathtub faucet leak in owner-occupied residence. Upon inspection, identified dripping from both the tub spout and cold water handle of vintage three-handle faucet assembly mounted on tiled wall above green bathtub. Measured existing fixture spacing and documented worn components showing signs of age and deterioration. Completed part order form to procure replacement parts for repair of leaking faucet components.