Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in May 2026.
The most recent job was on May 28, 2026.
Hurlburt Heating & Plumbing has completed 317 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Responded to a leak on a recently installed tanked water heater that was still producing hot water but had active water seepage at a connection point. Upon inspection, identified a heavily corroded fitting that had not been replaced during the initial installation. Removed and replaced the compromised fitting with new hardware, then performed a thorough leak check to verify proper seal and connection integrity throughout the system.
Responded to no cooling complaint with loud buzzing noise at furnace during AC operation. Upon inspection, diagnosed failed blower motor in oil furnace that would not spin freely and produced loud buzzing sound when energized. Tested motor at multiple speed taps to confirm complete motor failure. Provided replacement estimate for blower motor assembly. Homeowner elected to self-install replacement motor. Restored system to powered-off state and documented findings with photos of failed motor assembly.
Responded to no cooling complaint on residential Tempstar air conditioning system manufactured in 1988. Upon arrival, performed diagnostic evaluation of outdoor condensing unit. System exhibited complete failure to provide cooling to entire home. Diagnostic testing confirmed compressor failure, rendering the unit inoperable. Given the age of the equipment at 36 years old and the cost of compressor replacement versus system efficiency, recommended full system replacement. Documented unit condition with photographs showing exterior condenser with accumulated debris and wear consistent with age. Comfort advisor contacted to provide replacement options and system upgrade recommendations to homeowner.
Responded to no cooling complaint on heat pump system. Unit was locked out on high discharge line temperature fault code 415. Upon inspection and diagnostics, determined the thermostatic expansion valve (TXV) had failed, causing the high temperature condition. Documented findings with photos showing outdoor unit condition and coil assembly. Provided estimate for TXV replacement, which was approved. Parts have been ordered and installation will be scheduled upon arrival.
Responded to estimate request for removal of abandoned lavatory drain pipe protruding through floor in former bathroom location. Accessed piping from basement level through floor opening and cut off obsolete drain line and S-trap assembly below floor level. Cut remaining pipe stub flush with finished floor surface on upper level to eliminate tripping hazard and allow for proper floor refinishing. Removed debris and verified no active plumbing connections were affected during pipe removal process.
Responded to callback on newly installed Lennox unit experiencing short cycling issues. Upon arrival, performed diagnostic testing on the outdoor condenser unit and found system was severely overcharged. Measured subcooling at 45°F (specification 6°F) and head pressure at 354 PSIG (specification 245 PSIG at 70°F ambient). Recovered 2 pounds of refrigerant from the system to bring subcooling within manufacturer specifications. Verified proper operation with 18°F temperature split across the evaporator coil and confirmed 4°F space temperature drop within 45 minutes of runtime. System now operating correctly with no short cycling observed.
Responded to service call for leaking water heater in basement utility area. Upon arrival, identified an A.O. Smith tanked water heater with active leak originating from the bottom of the unit, indicating tank failure. Confirmed unit was beyond repair due to internal tank corrosion and breach. Proceeded with complete water heater replacement, removing the failed unit and installing new A.O. Smith tanked water heater. Connected copper supply lines with shutoff valves, installed temperature and pressure relief valve with proper discharge piping, and verified all connections for leaks. Tested unit operation, confirmed proper heating function, and ensured compliance with local plumbing codes.
Responded to no cooling call on 15-year-old Lennox system. Upon arrival, found outdoor condenser fan motor not operating while indoor unit was running. Diagnosed failed condenser fan motor by testing capacitor, which read 4.0 microfarads. Replaced capacitor to verify motor failure, but motor still failed to start despite spinning freely by hand. Confirmed condenser fan motor requires replacement. Provided repair estimate to homeowner via email for approval before proceeding with motor replacement.
Completed comprehensive air conditioning maintenance tune-up on a 9-year-old system. During inspection, discovered a cracked condensate drain line which was successfully repaired to prevent water damage and ensure proper drainage. Performed standard maintenance protocol including electrical testing, coil inspection, and system performance verification to maintain optimal cooling efficiency.
Completed comprehensive AC maintenance tune-up on 6-year-old system per maintenance agreement. Outdoor condenser coil was heavily soiled with organic debris, leaves, dirt, and plant matter; thoroughly cleaned coil fins to restore proper airflow and heat transfer efficiency. System operational with no additional concerns noted.
Performed comprehensive annual AC tune-up on 5-year-old system, verifying all indoor and outdoor components for optimal performance. Inspected furnace blower speeds and confirmed proper settings, checked air filter condition, tested all electrical components which measured within manufacturer specifications, performed coil cleaning by removing panels and rinsing condenser coils until clear, and flushed evaporator drain line to ensure proper drainage. Connected manifold gauges to verify refrigerant charge, confirmed system operating at proper levels with 22-degree temperature split across evaporator coil, and verified all components functioning correctly with no deficiencies noted.
Responded to no-heat call on oil-fired furnace. Performed comprehensive system inspection including all components and heat exchanger, finding no visible issues with burner fan, controls, or combustion chamber. Diagnosed fuel delivery failure caused by completely worn oil pump coupling with stripped teeth preventing proper pump operation. Replaced failed coupling, restored fuel flow to nozzle, and verified successful ignition and normal system operation. Advised homeowner that given the age of the unit, replacement should be considered for future planning.
Responded to low compressor error on Water Furnace ENVISION geothermal system that was not cooling. Diagnosed and replaced failed capacitor, then verified proper system operation with 24-degree temperature drop and 6-degree temperature rise across coaxial heat exchanger in cooling mode. Measured ground loop water pressure at 5 psi inlet and 1 psi outlet; loop pressure is slightly low but acceptable given system has operated without maintenance for 17 years.
Responded to no heat call at commercial facility. Began replacement of 7 zone valves with 3/4" fittings, including installation of necessary reducers (1 1/4" to 3/4" and 1" to 3/4") and new T4 thermostat. Work in progress with two technicians on site; zone valve replacement partially completed and will require additional time to finish installation and restore full heating functionality to all zones.
Completed scheduled Rewards maintenance tune-up on 3-year-old residential air conditioning system. Disassembled outdoor condenser unit and thoroughly cleaned heavily soiled condenser coil which exhibited significant accumulation of dirt, dust, and environmental debris with greenish-brown discoloration between fins. Washed coil and components, inspected all operational elements, and verified system performance with 22° temperature drop across evaporator coil, confirming proper refrigerant charge and efficient operation. Unit returned to full operational status with no issues identified.
Completed comprehensive AC maintenance tune-up on 17-year-old forced-air system. Unit is functioning properly at this time, with all components inspected and serviced according to maintenance agreement specifications. Comfort advisor recommendations provided for aging equipment.
Responded to outdoor faucet that had been dripping throughout the winter season. Upon inspection, determined the hose bib had sustained freeze damage and was leaking at the connection point. Removed the damaged hose bib assembly and installed a new frost-free hose bib with ball valve to prevent future freeze-related failures. Tested system for proper operation and verified no additional leaks were present.
Completed preventive maintenance on 15-year-old Lennox air conditioning system. Cleaned outdoor condenser unit, inspected all electrical components and connections, verified air filter condition, and cleared condensate drain line. All systems tested and operating within normal parameters with no deficiencies identified.
Completed annual plumbing inspection of residential property. Conducted comprehensive evaluation of all plumbing fixtures, supply lines, drainage systems, and exposed piping in bathroom and utility areas. All components found to be functioning properly with no leaks, corrosion, or deficiencies requiring immediate attention at this time.
Returned to property to complete furnace control board installation under warranty. Successfully replaced defective control board and verified all system operations functioning properly upon completion.