Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI between May 2026 and June 2026.
The most recent job was on June 16, 2026.
Hurlburt Heating & Plumbing has completed 317 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Conducted comprehensive assessment of whole-home in-floor radiant heating system experiencing multiple leaks at manifold connections and zone valves. Identified necessary repairs including replacement of T-fitting in bedroom ceiling and basement, three-port manifold replacement near air handler, and one Erie zone valve. Recommended upgrading expansion tank to 30-gallon capacity with wall relocation and proper strapping, installation of new pressure relief valve and automatic air vent, and complete boiler maintenance service with cleaning. Documented existing conditions with photographs showing copper manifold distribution system with PEX tubing connections, multiple zone valve assemblies, and current expansion tank configuration. Project scope transferred to plumbing department for formal estimate preparation due to extent of hydronic system repairs required.
Responded to customer inquiry regarding recently installed water softener system. Conducted on-site water hardness testing to verify system performance. Test results confirmed water softener is functioning properly, with water measuring within acceptable soft water parameters. Documented system operation with photos for service records.
Responded to service call for 2019 Lennox air conditioning system with water leakage issue. Upon arrival, unit was off and water was present on floor. Removed access panel to inspect evaporator coil and drain system. Performed diagnostic water test on drain pan which revealed complete blockage preventing proper drainage. Located obstruction in barb fitting of condensate drain line. Cleared blockage from barb fitting using compressed air and thoroughly flushed drain pan to remove accumulated debris. Restored unit to operation and monitored condensate drainage system to verify proper flow and function. System cooling normally with condensate draining as designed.
Responded to service call for gas water heater repeatedly cycling off and tripping breaker. Upon arrival, inspected 16-year-old unit and identified faulty gas valve operation. Reset gas valve and successfully restored unit to operational status. Documented existing equipment and utility room configuration with photos. Provided replacement estimate due to age of unit and uncertain longevity of current repair, as temporary fix may not provide long-term reliability given the advanced age of the water heater.
Responded to bathroom sink faucet failure. Removed and replaced deteriorated single-handle faucet assembly with new chrome single-handle unit. Installed new shut-off valve to address existing valve malfunction. Tested water flow and temperature control operation. Verified proper drain function and checked all connections for leaks. System restored to full working condition.
Responded to no cooling complaint on commercial rooftop unit. Found unit locked out on fault code 42 due to tripped three-phase motor relay, likely caused by power outage earlier in the day. Reset motor protection relay and monitored system operation for 35 minutes to verify proper functionality. Unit returned to normal cooling operation. Noted dirty filters requiring replacement by facility management. Control panel displayed dehumidification mode with humidity reading at 48.8%. All electrical connections inspected and secured during troubleshooting.
Responded to no cooling complaint on 3-year-old residential air conditioning system. Upon inspection, located refrigerant leak on condenser high-side line. Provided estimate for leak repair, system evacuation, and refrigerant recharge. Customer declined repair service and requested replacement options due to cost considerations relative to system age.
Installed a 40-gallon power vent gas water heater to replace existing unit. Upon inspection, determined original vent pipe was inadequate for standard atmospheric venting, requiring upgrade to power vent model to ensure proper exhaust ventilation and code compliance. Completed installation with appropriate electrical connections and venting configuration in mechanical room adjacent to existing HVAC system.
Responded to no cooling complaint on 21-year-old Tempstar split system with outdoor condensing unit. Upon arrival, confirmed system inoperative with indoor temperature at 80°F. Performed diagnostic evaluation and identified failed capacitor as root cause of system failure. Replaced defective capacitor and restored system to operational status. Due to advanced age of equipment, provided pricing options for complete system replacement as requested by homeowner.
Responded to no hot water complaint on 18-year-old A.O. Smith ProMax tanked water heater. Diagnosed pilot light failure to remain lit and determined faulty gas valve (model 186300-000 37c73u-652). Due to age and condition of unit, recommended and installed replacement 40-gallon natural gas water heater with natural draft venting. Installation included 3-inch vent piping, three-quarter inch gas valve with three-quarter to half-inch reducer, and 4 feet of gas pipe. Verified all connections, tested for proper operation and gas leaks, and confirmed hot water delivery upon completion.
Responded to no cooling complaint on 7-month-old system with water leakage at furnace. Found evaporator coil completely frozen with heavily restricted high-MERV filter causing insufficient airflow. Recommended maximum MERV 7 filtration, adjusted thermostat minimum cooling rate from 31% to 42%, and increased fan-on speed to 525 RPM to improve airflow. Unable to verify refrigerant charge due to frozen coil condition; advised system shutdown period for proper thawing before refrigerant charge verification can be completed on callback.
Completed annual cooling system maintenance per membership agreement. Inspected and serviced Lennox outdoor condensing unit, including cleaning of condenser coil and top grille, verification of refrigerant pressures, and operational testing of all components. Inspected Aprilaire Model 5000 electronic air cleaner and furnace filter media, noting significant debris accumulation requiring replacement. All equipment operational upon completion of tuneup service.
Replaced a 30 year-old 50-gallon Permaglas electric water heater with a new 50-gallon Bradford White electric water heater with 10-year warranty. The removal required two technicians due to basement location and unit weight. Successfully disconnected existing electrical and plumbing connections, removed the deteriorated unit showing significant rust and wear at the base, and installed the new water heater with proper copper piping connections and electrical hookup to manufacturer specifications.
Responded to service call for non-functional outdoor spigot requiring activation and shut-off valve repair. Upon inspection, discovered the hose bibb shut-off valve was missing its handle, which had been inadvertently left off during previous hose bibb replacement work completed last year. Successfully installed new shut-off handle on existing valve assembly, restoring full operational control of the outdoor water supply system.
Performed scheduled maintenance on Locinvar boiler system. Removed burner assembly and thoroughly cleaned heat exchanger and flame sensor. Flushed condensate system and verified proper operation upon completion.
Performed comprehensive preventive maintenance tune-up on 8-year-old air conditioning system. Unit exhibited heavy debris accumulation on condenser coils, which was thoroughly cleaned after disassembly. Verified system performance with 20-degree temperature differential across evaporator coil, confirming proper refrigerant charge and heat transfer. Noted MERV 16 air filter nearing saturation; homeowner will order replacement. Inspected all electrical components, mechanical operation, and safety controls—all functioning within manufacturer specifications.
Completed estimate for replacement of two leaking outdoor lawn faucets. Inspection revealed both exterior spigots required replacement due to active leaks. Assessment included evaluation of existing plumbing infrastructure in crawl space, including copper supply lines and brass fittings. Recommendation provided for installation of two new outdoor faucets and one new shut-off valve for the side lawn faucet to ensure proper water control and prevent future leaks.
Responded to no cooling complaint on 15+ year old air conditioning system. Upon inspection, found inadequate cooling with only 10° temperature split across evaporator coil and freezing distributor tubes. Diagnostic testing revealed suction pressure at approximately 40 PSI, indicating significant refrigerant undercharge in R22 system. Due to phase-out of R22 refrigerant and age of equipment, advised customer that system replacement is most viable option. Coordinated with sales team for replacement system evaluation and pricing.
Responded to no cooling complaint where furnace was activating simultaneously with air conditioning system. Diagnosed issue as secondary downstairs thermostat hard-wired directly to furnace control board, bypassing main thermostat control. Found legacy thermostat set at 70°F, creating conflicting call for heat whenever AC compressor engaged. Traced all wiring and control circuits to identify dual thermostat configuration. Adjusted secondary thermostat setpoint to minimum position to prevent heat call during cooling season. Verified proper system operation with AC cycling correctly without furnace activation. System now cooling as designed with no simultaneous heating.
Responded to a bathroom sink with severely restricted drainage that was completely plugged. After initial assessment confirmed solid blockage, deployed mechanical snake equipment through the drain line approximately seven times to clear the obstruction. Successfully restored full drainage flow to the fixture, with sink now draining at optimal rate.