Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in August 2026.
The most recent job was on August 20, 2026.
Hurlburt Heating & Plumbing has completed 319 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Completed comprehensive preventive maintenance tune-up on 6-year-old Lennox 16ACX1-030-230A01 air conditioning system per family rewards agreement. Performed full system inspection, verified R-410A refrigerant charge, tested electrical components, cleaned condenser coil, and confirmed all operating parameters within manufacturer specifications.
Completed plumbing inspection of residential water heater located in utility closet. Unit exhibited active leaking from bottom section, consistent with age-related tank deterioration and sediment buildup. Documented condition with photographs showing water heater installation, surrounding area, and evidence of leak source for customer records and replacement recommendations.
Completed warranty parts installation on Daikin outdoor mini-split unit. Replaced defective fan motor, fan blade, and control board to restore proper system operation. All replacement components were installed per manufacturer specifications, unit tested and confirmed operational upon completion.
Completed comprehensive seasonal maintenance on both air conditioning and furnace systems under preventative maintenance agreement. Performed complete tune-up procedures on both units including inspection of electrical components, control boards, wiring connections, and heat exchangers. Verified proper operation of all safety controls, cleaned condensate pans, checked refrigerant levels, and tested system performance to ensure optimal efficiency for the upcoming heating season.
Responded to service call for malfunctioning garbage disposal unit. Upon inspection, found one cutting knife jammed, causing reduced performance. Presented repair option to customer, who opted for full unit replacement. Removed existing disposal and installed new InSinkErator Pro Disposer 3/4 HP unit with electrical cord. Secured mounting assembly to sink drain opening, verified all connections, and tested operational functionality. Confirmed proper grinding performance and inspected all plumbing connections for leaks with no issues detected.
Completed comprehensive seasonal maintenance on 15-year-old furnace and air conditioning system as part of maintenance agreement. Performed full tune-up procedures on both units including inspection, cleaning, and testing of all components per manufacturer specifications. Both systems evaluated and found to be operating within normal parameters with no immediate concerns identified.
Completed installation of two customer-supplied widespread lavatory faucets with wall-mounted fixtures and handles in brushed nickel finish. Replaced existing shower valve, spout, and trim assembly utilizing existing access from behind the valve. All installations tested for proper operation and verified leak-free connections upon completion.
Completed scheduled Family Rewards cooling maintenance visit on residential air conditioning system. Performed comprehensive AC tuneup including full system inspection, washed outdoor condenser coil to remove debris and improve heat transfer efficiency, and verified all operational parameters. System operating properly with no issues discovered during service.
Completed comprehensive maintenance tune-up on 7-month-old geothermal heat pump system with in-floor heating zones. Verified operation of geothermal unit, measured loop and load side pressures and temperatures with satisfactory 20-degree temperature differential across system. Tested capacitor reading 27.5 microfarads, slightly below rated 30 microfarads but within acceptable operating range. Inspected and confirmed proper operation of all zone valves controlling in-floor radiant heating system. Performed standard preventive maintenance procedures per agreement requirements, including visual inspection of mechanical room equipment, water heater connections, pressure tank, and associated plumbing components.
Responded to service call for water heater producing banging noise during operation. Upon inspection, diagnosed failing flame igniter as primary cause of operational issues. Replaced flame igniter, flame sensor, and burner gasket to restore proper combustion and eliminate noise. Discussed unit's overall condition and recommended considering replacement due to age and component wear patterns observed during service.
Performed seasonal tune-up and preventive maintenance on geothermal HVAC system for air conditioning operation. Cleaned condensate trap, verified loop pressures and temperatures within specifications, and inspected contactor operation. Capacitor testing revealed readings of 27 and 30 microfarads, which are outside acceptable tolerance range, requiring replacement. Cooling season maintenance completed; heating system inspection scheduled for fall.
Completed comprehensive tune-up on 2-year-old Lennox air conditioning system and 1-year-old furnace under maintenance agreement. Performed full furnace inspection with all components verified within manufacturer specifications, replaced air filter, confirmed blower assembly clean and operating properly, and verified evaporator coil clean with proper drainage. Inspected and thoroughly cleaned outdoor condenser unit which had accumulated significant debris. Tested both heating and cooling modes with 15-minute runtime verification, confirmed proper temperature differentials and system performance with no operational issues detected.
Completed inspection of malfunctioning Roman tub faucet diverter that had been sticking and required manual force to operate. Diverter mechanism failed and would no longer lift to activate the handheld sprayer function. After attempting repair, determined complete replacement of trim kit and valve body is required, necessitating access through basement ceiling below the fixture.
Completed comprehensive plumbing inspection of residential property focusing on reported leaking pipes extending from master bathroom to basement level. Inspected exposed PVC drainage piping system in utility area, examining multiple elbow joints, vertical and horizontal pipe runs, and connection points for signs of leaks or deterioration. Evaluated master bathroom plumbing fixtures including sink, faucet assembly, and associated supply lines for proper operation and potential water intrusion issues.
Responded to service call for loose bathroom faucet handle on chrome two-handle centerset faucet assembly. Upon inspection, determined that the handle had become unspun from its mounting base, causing it to detach during normal operation. Tightened and secured the faucet handle back onto the valve stem, restoring proper function and stability to the fixture.
Responded to a kitchen sink backup and toilet leak. Upon inspection, found the kitchen sink drain clogged with grease buildup. Cleared the blockage using a small drain machine and restored proper drainage. Identified active leak at toilet base. Pulled toilet, removed deteriorated wax ring, installed new wax ring, and properly reset toilet to eliminate leak. Both plumbing issues resolved and fixtures returned to normal operation.
Removed and disposed of existing failed water heater. Supplied and installed new 12-gallon Bradford White water heater on wall-mounted wooden platform. Connected copper supply lines with brass fittings and installed blue-handled ball valve for system shut-off control. Reconnected temperature and pressure relief valve and added new drain line to unit, as previous installation lacked proper drainage. Set thermostat to match previous unit's temperature setting. Installation includes manufacturer warranty and 1-year parts and labor warranty. System tested and operational upon completion.
Completed comprehensive maintenance agreement service on Daikin mini-split air conditioning system and boiler. Performed AC tune-up including cleaning and inspection of electrical components on outdoor condenser unit, removed and verified clean filters from indoor head unit, and confirmed proper drainage operation. Conducted boiler inspection of routine components, removed and cleaned trap and igniter assembly with all measurements found within manufacturer specifications. System testing included running mini-split for 15 minutes with temperature split measuring 18-20 degrees, verified proper operation of in-floor heating and domestic hot water functions. All equipment operating as designed with no deficiencies noted.
Completed routine air conditioning tune-up on 17-year-old Lennox system in residential basement installation. Performed comprehensive maintenance including thorough washing of outdoor condenser coil to remove accumulated debris and improve heat transfer efficiency. All system components inspected and found operating within normal parameters with no issues identified.
Responded to no-cooling call on 6-year-old Lennox HVAC system where blower motor was not functioning, resulting in no airflow throughout the home. Diagnosed failed blower motor assembly and ordered replacement part for equipment repair. Unit specifications documented and customer informed of repair timeline.