Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in October 2025.
The most recent job was on October 20, 2025.
Hurlburt Heating & Plumbing has completed 314 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Performed routine furnace tune-up on aging FRP unit. Replaced customer-supplied air filter, inspected primary and secondary heat exchangers with no compromises found. All electrical components, capacitors, and gas pressures tested within specification with proper temperature rise of 65 degrees. System operated normally during 15-minute test run after condensate lines were cleared.
Responded to warranty service call for heat pump experiencing high-pressure trips in heating mode. Diagnostic testing revealed significant overcharge from installation. Removed approximately 2 pounds of excess refrigerant and adjusted charge according to manufacturer specifications. Post-service testing confirmed normal operating pressures with successful heating cycle performance.
Successfully replaced a faulty gas valve on LP system with a new single-stage valve, performing necessary conversion using the existing spring. Leak-tested all fittings, calibrated manifold pressure to 9.3 by adjusting the external regulator, and verified proper operation through multiple power cycles. Warranty service completed with no issues observed during extended runtime testing.
Replaced damaged drain connections on water softener and acid neutralizer that were leaking and causing water accumulation on basement floor. Original softener drain piece was cracked due to over-tightening; ordered replacement part after completing temporary repair to resolve immediate leak issues.
Performed standard preventive maintenance on 18-year-old furnace. Inspection revealed critical deficiencies including cracked collector box and severely rusted burners. Customer informed of findings; replacement equipment consultation scheduled for Monday with comprehensive repair options presented.
Responded to no heat complaint for 5-year-old furnace with reported fan failure. Diagnostic testing revealed inoperative blower motor. Attempted repair by installing replacement motor control module, but communication failure persisted between module and motor. Submitted parts order for new blower motor and control board to restore system functionality.
Diagnosed and repaired electric furnace issue where blower fan was running continuously. Found stuck relay in the electric furnace that prevented proper termination of airflow when using wood heat. Replaced faulty relay and secured damaged wiring for unused second stage heat circuit by turning off the associated breaker and taping off burnt wires after confirming with resident that this heating stage was not utilized.
Responded to customer complaint of pulsating/whooing noise from outdoor heat pump unit during operation. Discovered condenser coil was significantly restricted with debris, causing airflow starvation which resulted in unit vibration. Removed shroud, thoroughly cleaned condenser coil, and completed full heat pump tune-up. System operated normally after service with no recurrence of noise issue.
Responded to no heat complaint for 4-year-old LP furnace with failed ignition code. Diagnosed sticking gas valve solenoid by confirming proper igniter operation and 24V to valve without opening. Temporarily restored operation by tapping valve and cycling switch. Recommended gas valve replacement as permanent solution and advised customer on future tune-up service during same visit.
Diagnosed and resolved no heat issue on geothermal system by bleeding trapped air from hydronic side. Successfully restored floor heat operation and verified proper functionality of both geothermal unit and backup boiler heat system.
Completed comprehensive plumbing inspection as part of membership service. Identified water softener drain line leak and completed necessary repairs. Further investigation recommended to pinpoint source of secondary leak observed from one of the tanks.
Replaced leaking 50-gallon electric water heater with new unit. Completed installation with existing plumbing configuration, connecting to copper supply lines, PEX tubing, and existing expansion tank. System was successfully installed alongside customer's water softener system in utility area.
Performed scheduled HVAC maintenance agreement service on residential units in both house and garage per customer's requested sequence. Verified system operation with Lennox smart thermostat showing proper temperature control and ventilation function. No issues identified during inspection; filter kits and humidifier canisters were ordered and are available at the Menomonie shop.
Performed scheduled bi-annual maintenance on 5-year-old mobile home furnace under Reward membership agreement. Custom-cut and replaced air filter, inspected heat exchanger, and verified proper furnace operation. Completed comprehensive tuneup with all systems functioning normally.
Performed scheduled furnace maintenance on 3-year-old Goodman heating system under Rewards membership agreement. Completed comprehensive tune-up including heat exchanger inspection, flame sensor cleaning, air filter replacement, and operational verification. All systems functioning properly with no defects identified.
Diagnosed mini split system failure with Tech Support, determining that excessive voltage (251v) from customer's solar installation was damaging control boards. Installed replacement parts for mini split, however unit remained non-operational due to component incompatibility. Submitted warranty claim for new control board, condenser fan motor, and sensors required to complete repair. Richardson's (original solar installer) has been notified to address the voltage backfeed issue.
Responded to a service call for multiple bathroom plumbing issues. Diagnosed and cleared a plugged toilet using an auger, extracted significant hair buildup from the bathroom sink drain which was causing slow drainage and odor, and tightened the pop-up assembly mechanism to restore proper functionality. Inspected bathtub drain but found no obstructions.
Diagnosed and repaired geothermal unit experiencing operational failure due to non-functioning pumps. Found defective control board with damaged fuse holder, installed breaker switch as solution, replenished loop water, and verified system operation. Secondary inspection of gas furnace confirmed both heating systems functioning properly, though noted floor heat water heater requires separate service.
Performed scheduled biannual maintenance on electric furnace and heat pump system under Rewards agreement. Conducted operational inspection of electric furnace with all functions verified working properly. Replaced humidifier water panel and assessed heat pump operation, confirming proper functionality of entire system.
Responded to service call regarding a leaking pipe above toilet in women's restroom. Upon inspection, identified a malfunctioning flushometer with damaged diaphragm. Replaced the flushometer diaphragm to resolve the leak and restored proper toilet function.