Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in October 2025.
The most recent job was on October 30, 2025.
Hurlburt Heating & Plumbing has completed 314 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Responded to service call for previously diagnosed part installation, but determined the supplied part was not the source of the issue. Inspection revealed a faulty control board and identified small cracks in the heat exchanger near press joints, documented with photos. Due to the furnace's age (approximately 18 years) and the need for both heat exchanger and control board replacement, recommended customer consult with an advisor regarding replacement options.
Performed a comprehensive inspection and safety check on the 2-year-old gas furnace as required by state regulations. Verified heat exchanger integrity, proper venting, burner functionality, and confirmed zero carbon monoxide readings. Repaired a minor condensate trap leak by disassembling and retightening components. Furnace passed all operational parameters and is in excellent condition. Inspection documentation has been completed and will be provided via email.
Responded to commercial no-heat call for heater in garage building. Diagnosed issue with blown fuse on circuit board; inspected all wiring connections which appeared intact. Possible power surge may have caused initial fuse failure. Successfully restored heater operation, though will monitor for potential recurring electrical issues.
Responded to service call regarding water heater valve leak. Identified slow drip from boiler drain at bottom of water heater (approximately one drip every 20 seconds). Tightened existing drain handle and installed protective cap to prevent further leakage.
Responded to service call to replace dual unit pressure switch as previously diagnosed. Upon full inspection, discovered significant crack in heat exchanger. Did not proceed with pressure switch installation due to safety concerns. Scheduled advisor visit and submitted proposal for heat exchanger replacement.
Performed comprehensive maintenance on two heating systems: 2-year-old indoor forced air furnace and 16-year-old outdoor central wood boiler. Identified and repaired minor gas leak on low pressure cut off switch of indoor furnace by tightening connection. Replaced MERV 16 Carbon Clean filter (16"x25"x5") and verified proper operation of all furnace components. Inspected wood boiler including damper functionality and associated components, confirming all systems in good working order.
Responded to geothermal heating system failure. Diagnosed incorrect temperature settings on wrinkle control heat tank and system overpressurization. Corrected temperature settings, monitored system heat-up cycle and verified proper operation. Observed significant corrosion and mineral deposits on copper pipe assembly with evidence of moisture exposure and potential leakage at connection points.
Responded to slow drainage issue in bathtub. Diagnosed minor blockage in trap located in basement. Successfully cleared the drain by removing P-trap and snaking through the opening and basement access point, restoring normal drainage function.
Installed new 50-gallon electric water heater to replace existing unit that was previously heated via central boiler. Temporarily stopped leak to allow time for proper installation. Completed conversion from boiler-heated system to standalone electric water heater with all necessary plumbing connections.
Diagnosed 33-year-old furnace with no heat issue despite functioning fan. Inspection revealed failed inducer motor and deteriorated black boot connection to collector box, both showing significant age-related wear and corrosion. Due to obsolete components and overall condition, recommended system replacement; scheduled consultation with advisor for replacement options.
Responded to no heat complaint for ceiling-mounted forced air furnace/makeup air unit in commercial space. Upon arrival, unit was operating normally without heating issues. Performed preventative maintenance including internal cleaning. Conducted multiple test cycles with successful operation each time, confirming system is now functioning properly.
Responded to no heat call at shop. Diagnosed tube heater failure due to burned out ignitor. Replaced ignitor, tested system operation, and confirmed proper heating function. Unit now operating normally.
Performed maintenance service on two gas furnaces. The newer ICP unit (3 years old) is operating properly with no issues identified. The older Goodman unit (approximately 10 years old) has a noisy inducer motor and shows signs of deterioration on the heat exchanger. Provided recommendations for repairs and replacement options for the older unit, though customer elected to defer service at this time. Both furnaces remain operational.
Responded to no heat complaint where furnace was not producing warm air. Diagnostic testing revealed unit was tripping on open limit. After inspecting all safety controls, determined that the inducer limit switch had failed while other limits tested normal. Replaced faulty inducer limit switch to restore proper furnace operation.
Responded to no heat complaint on 5-year-old furnace that was shutting down after 15-20 seconds of operation. Diagnosed pressure switch issue with fault code indicating "pressure switch stuck." Upon testing, identified one of the dual pressure switches exhibiting slow response and dull sound when manually actuated. Replaced faulty dual pressure switches, restoring normal system operation. Unit should still be under parts warranty.
Responded to no-heat service call for 10+ year old LP furnace. Diagnosed ignition failure sequence where combustion blower starts/stops and igniter activates but extinguishes before proper ignition. Inspection revealed both a failed control board and a hole in the primary heat exchanger (second cell from left). Recommended complete replacement of control board and heat exchanger. Took documentation photos of outdoor condensing unit and damaged circuit board for verification purposes.
Replaced leaking 8-year-old 50-gallon power vent natural gas water heater with a new Bradford White model. Installation included proper connection of copper water lines, PVC venting, and yellow flexible gas line in the utility room.
Diagnosed failing circulation pumps in commercial boiler system; identified bearings failing in control area/boardroom pump and seized pump for boiler nearest door. Temporarily resolved issues by deactivating problematic boiler and reducing speed on functioning pump while recommending replacement of both damaged pumps.
Responded to commercial no heat call for boiler system displaying "inlet pressure sensor error" code. Diagnosed issue as low water condition with boilers out on low water cut off. Found auto fill valve stuck closed; freed the mechanism and restored water to the system. After restoring proper water levels, monitored the system until circulation resumed and verified heating operation, noting one zone required extended time to warm up due to extensive piping.
Performed furnace tune-up on 3-year-old FRP system. Tested all components finding all within specifications, replaced dirty filter, verified proper gas pressures, inspected heat exchanger with no issues found, and confirmed proper venting. System operating correctly with 70-degree temperature rise during 15-minute test cycle.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.