Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI between October 2025 and November 2025.
The most recent job was on November 12, 2025.
Hurlburt Heating & Plumbing has completed 314 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Performed routine furnace tune-up on Goodman system. Replaced dirty filter, cleaned and balanced blower, cleared condensate trap and routine lines. Inspected heat exchanger showing normal wear on first back bends without compromises. Noted inducer motor drawing higher than specified amperage (3A vs 2A rated). System maintained proper gas pressures with 60-degree temperature rise during 15-minute operational test. Discussed with customer regarding heat exchanger condition and inducer motor, provided requested estimates for these components.
Successfully installed two new red circulator pumps with brass shut-off valves on copper pipes for the boiler system and main maintenance area as per estimate. Reprogrammed thermostat in back office, restoring functionality to the second non-working furnace.
Performed 8-12 year furnace tuneup on 20+ year old LP Trane system. Inspection revealed severely compromised heat exchanger with multiple cracks and holes. Documented damage with photos showing structural failure of heat exchanger. Arranged for sales advisor to visit same day to discuss replacement options.
Replaced failed factory-supplied threaded drain adapter on water treatment system that was causing a leak. Service required 1 hour to complete installation of new adapter, resolving the issue and restoring proper function to the system.
Performed scheduled fall tune-up on customer's boiler system per rewards membership agreement. Conducted comprehensive maintenance including burner removal and cleaning, pump inspection, and operational component testing. System functioning properly after service completion.
Responded to service call for noisy rooftop furnace. Diagnosed slipping belt and broken motor mounts. Performed comprehensive service including belt tightening and system operation check. Noted filters require replacement which customer will order separately. Submitted documentation for future blower motor replacement though unit is currently operational.
Performed 8-12 geothermal system tune-up under Rewards membership. Found system low on water, added water for in-floor heat system, and verified proper operation with normal pressure and temperature readings. Discussed supplemental heating options with homeowner Roy, who requested an estimate for a new gas furnace to be installed alongside the geothermal unit.
Responded to warranty service call for leaking water treatment system. Inspection of the Pentair equipment revealed broken components on the control valve assembly. Documented issue with photos, ordered replacement parts to resolve the leak.
Responded to no heat complaint in repair and wash bay areas. Diagnosed low water level in hydronic heating system, replenished water and bled air from zones. System restored to operation with pumps functioning, though some residual air remains in lines which may self-resolve. All zones now receiving heat, but may require follow-up bleeding if heating issues persist.
Responded to a call to install a previously ordered cap for horizontal draft hood replacement. Upon inspection, discovered the cap was incompatible with the existing system. While measuring for alternative stainless steel screen installation to prevent bird entry, detected gas odor outside. Investigation revealed a broken igniter (previously installed by Trevor) causing the heater to lock out. Replaced igniter to restore heater function and identified need for appropriate screening material to prevent future bird nesting issues.
Performed scheduled furnace tune-up on 7-year-old FRP system under rewards membership. Inspected heat exchanger (no defects found), cleaned condensate, flame sensor, and burners. Replaced customer-supplied MERV 16 filter and verified proper furnace operation. All maintenance tasks completed per agreement specifications.
Responded to no-heat complaint on 20-year-old furnace. System was operational upon arrival but performed basic service including heat exchanger inspection, flame sensor cleaning, and condensate check. Identified a crack in the collector box and possible intermittent control board malfunction consistent with customer's description. Documented issues with photos and scheduled follow-up for potential component replacement.
Responded to a kitchen sink clog causing backup. Diagnosed excessive length of drain line with deteriorated galvanized pipe section. Removed 6-foot section of compromised galvanized piping and replaced with new PVC drain line, restoring proper drainage function.
Responded to no heat call for a 20+ year old furnace. Diagnosed complete failure of control board despite proper power supply. Furnace inspection revealed severe dirt accumulation in blower cabinet and secondary heat exchanger. After verifying heat exchanger integrity, installed new control board which successfully restored normal heating function.
Responded to service call for no heat complaint on a Revolv mobile home furnace (approximately 10 years old). Upon inspection, diagnosed failed draft motor with worn bearings causing loud noise. Ordered replacement draft motor to restore proper system operation.
Responded to no-heat call for 10-year-old Revolv mobile home furnace. Diagnosed failed draft motor with worn bearings causing loud operational noise. Ordered replacement draft motor to restore proper heating function.
Completed annual 10-2 boiler tune-up per maintenance agreement. Performed flame retention pattern adjustment, cleaned routine components, bled radiators to improve system efficiency, and repaired minor gas leak on pilot assembly. Visual inspection of pressure gauge and piping system conducted. Vacuum-cleaned burner chamber to ensure proper combustion.
Responded to service call for newly installed furnace (8 days old) that ceased providing heat. Discovered condensate drain blockage caused by a wire nut lodged in the drain fitting, preventing proper drainage. Removed obstruction and verified proper condensate flow, restoring normal furnace operation.
Responded to service call for previously diagnosed part installation, but determined the supplied part was not the source of the issue. Inspection revealed a faulty control board and identified small cracks in the heat exchanger near press joints, documented with photos. Due to the furnace's age (approximately 18 years) and the need for both heat exchanger and control board replacement, recommended customer consult with an advisor regarding replacement options.
Performed a comprehensive inspection and safety check on the 2-year-old gas furnace as required by state regulations. Verified heat exchanger integrity, proper venting, burner functionality, and confirmed zero carbon monoxide readings. Repaired a minor condensate trap leak by disassembling and retightening components. Furnace passed all operational parameters and is in excellent condition. Inspection documentation has been completed and will be provided via email.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.