Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in November 2025.
The most recent job was on November 28, 2025.
Hurlburt Heating & Plumbing has completed 316 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Responded to no-heat call for an aging oil furnace in barn office. Diagnosed intermittent ignition failure; manipulated primary control which resolved the issue temporarily. System eventually fired up and cycled properly through multiple thermostat tests. Inspection revealed severely rusted flue pipe with significant holes due to environmental exposure. Heat exchanger appeared intact without visible cracks. Recommended replacement of primary control, complete oil tune-up service, and replacement of deteriorated flue pipe components.
Responded to no-cooling complaint in server room with two malfunctioning units. Diagnosed ceiling cassette unit with failed contactor requiring specialized replacement part. Second system (Lennox split unit) found completely depleted of refrigerant with damaged condenser coil at bottom. Ordered replacement contactor for cassette unit and requested service advisor to quote replacement of the damaged split system.
Responded to a No Heat service call for a 25+ year old oil furnace that another technician was unable to repair previously. Diagnosed failed primary control, replaced the component with customer approval. System tested successfully after repair, restoring proper heating operation.
Installed replacement parts on mini split system, however unit remains non-operational. Following extensive troubleshooting with Technical Support, determined that excessive incoming voltage (251V) from customer's solar installation is damaging control boards. Identified need for replacement control board and condenser fan motor. Compressor requires further testing with mega ohm meter for complete diagnosis. Customer has been informed that a solution to reduce incoming voltage must be implemented before proceeding with additional repairs.
Performed standard tune-up on 20+ year old furnace that customer reported was not heating properly on Sunday. Inspection revealed a significant crack in the heat exchanger, which was documented with photos. Recommended unit replacement due to age and safety concerns associated with compromised heat exchanger.
Completed annual maintenance tune-up on 3-year-old Lennox heat pump system with high-efficiency furnace. Unit was functioning properly with no issues detected. Performed temperature measurements and inspected electrical components. Filter is located on side of furnace; noted absence of return ventilation.
Performed standard furnace tune-up with inspection of routine components and air filter (which was clean). Adjusted heat pump defrost termination setting from 50° to 100° after customer reported frost formation during operation. Verified heat pump ambient lockout is properly set at 30°. Demonstrated humidifier servicing procedures to customer and reviewed thermostat settings.
Completed scheduled maintenance tune-up on 2-year-old Lennox high-efficiency furnace. Performed comprehensive inspection of all mechanical components and electrical connections, with particular attention to the control board circuitry and blower assembly. Cleaned flame sensor as preventative maintenance. System operating within normal parameters with no operational concerns identified. Customer enrolled in Family Rewards program.
Responded to service call for a Moen shower spout leaking significantly from the back seam. Leak was causing water to penetrate into garage below. Determined previous installation (completed approximately one year prior) had failed. Removed damaged fixture and installed new shower spout to resolve the leak.
Performed annual maintenance tune-up on 1-year-old Lennox high efficiency furnace. Cleaned flame sensor and replaced customer-supplied 16x20x1 filter. System operating properly at time of departure.
Performed annual furnace tune-up on 1-year-old high-efficiency gas furnace per maintenance agreement. Cleaned condensate and flame sensor, conducted complete operational check of system. Unit functioning properly with no issues identified.
Responded to a callback for a previously sold horizontal draft hood replacement. Found the heater locked out due to a broken igniter, which was replaced to restore proper operation. Installed stainless steel screen with hose clamps on tube heater exhaust to prevent bird intrusion, noting that the previously ordered cap was not suitable for this application.
Performed annual furnace tuneup on 1-year-old Lennox system. Identified and repaired exhaust pipe leak by cutting out affected section and regluing. Evaluated furnace operation in both low and high fire modes with satisfactory results. Addressed boiler issue by adjusting Taco 00e-3 circulator pump setting from high to medium, successfully eliminating humming noise. Recommended boiler tech for inoperative in-floor heating system.
Responded to service call for pot filler leaking from the joint between spout and deck mount. Diagnosed issue with leakage at base. Replaced cartridge and installed new O-rings on the spout assembly to resolve the leak.
Responded to service call for flushing issues with home's only toilet. Completed installation of a new toilet on second level after finding the original toilet was plugged and deteriorated with significant corrosion in the drain pipe and surrounding floor area. Installed new toilet, adjusted water flow, tightened bolts and supply connections, and mounted seat.
Performed routine maintenance on 13-year-old LP furnace. System exhibited dust accumulation; cleaned flame sensor and inspected interior components with borescope. Discovered non-functional humidifier which customer declined to repair. Verified system is operating correctly post-service.
Responded to service call for 40-year-old furnace with severe operational issues. Diagnosed multiple critical safety concerns including 70-80 PPM carbon monoxide leakage from front of unit, flame rollout during ignition, oil leakage from deteriorating blower motor, and unstable squirrel cage causing grinding and rattling noise. System was shut down for safety due to dangerous CO levels and aging components beyond serviceable condition.
Responded to service call for toilet flushing issues. Upon inspection, found severe deterioration around floor drain with extensive rust damage to metal fittings. Discovered heavily corroded cast iron pipe with significant water damage affecting surrounding wooden structural elements. Removed old toilet and replaced with new unit due to irreparable plumbing infrastructure damage.
Inspected 27-year-old 40-gallon gas water heater with standard vent that was experiencing no hot water pressure. Observed significant water damage and mold on surrounding walls indicating long-term moisture issues. Assessed aging system components including expansion tank and connecting copper piping network. Equipment was functional but at end of service life, requiring replacement to restore proper hot water pressure.
Performed routine furnace tune-up on Goodman system. Replaced dirty filter, cleaned and balanced blower, cleared condensate trap and routine lines. Inspected heat exchanger showing normal wear on first back bends without compromises. Noted inducer motor drawing higher than specified amperage (3A vs 2A rated). System maintained proper gas pressures with 60-degree temperature rise during 15-minute operational test. Discussed with customer regarding heat exchanger condition and inducer motor, provided requested estimates for these components.