Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI in December 2025.
The most recent job was on December 17, 2025.
Hurlburt Heating & Plumbing has completed 316 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Performed tune-up on 27-year-old Heil furnace. Diagnosed vibrating noise in basement traced to condensation pump. Inspected heat exchanger and found questionable areas requiring attention. Documented condition of gas valve (SV9501M 2726) and overall system configuration for follow-up recommendations.
Tested mini-split system with multiple issues and installed replacement parts as specified. Upon installation, unit remained non-operational. After consultation with technical support, determined high voltage from customer's solar system (251V) is likely damaging control boards. Recommended replacement of control board and condenser fan motor pending resolution of excessive voltage from solar back-feed.
Responded to complaint of mildew odor emanating from heating system of 3-year-old furnace. Conducted thorough inspection of furnace, blower cabinet, coil, and heat exchanger with no visible issues identified. Observed mouse droppings near supply boot and suspect deceased rodent in ductwork is causing odor. Customer opted to defer further investigation at this time.
Performed maintenance tune-up on 2-year-old Lennox furnace. Inspected internal components and heat exchanger. Found humidifier non-operational due to failed transformer and corroded drain. Discussed adding condensate pump with Wayne, recommended transformer replacement and humidifier replacement to restore proper system functionality.
Performed annual maintenance on a 2-year-old Lennox high efficiency furnace. Completed comprehensive inspection including verification of all mechanical components, opened humidifier damper, and confirmed proper system operation. Filter was inspected and system is currently functioning as designed.
Performed furnace tune-up and identified root causes of home condensation issues. Corrected furnace pitch that was causing condensate leaks from the secondary, and sealed intake/exhaust penetrations at siding with silicone to prevent water intrusion. Verified all electrical components within specifications, heat exchanger integrity intact, and confirmed proper system operation with 65-degree temperature rise.
Performed annual furnace tune-up on 20-year-old natural gas system. Discovered detached rollout switch during burner inspection, which presented a significant safety hazard. Replaced switch with compatible component and restored proper operation. Visual inspection of heat exchanger revealed several suspicious areas that warrant monitoring but don't require immediate action. Customer advised about planned water heater replacement in spring.
Responded to no heat emergency for 60-year-old natural gas furnace. Discovered failed gas valve and suspected crack in heat exchanger with visible corrosion and deterioration documented in inspection photos. Due to safety concerns and age of system, recommended immediate replacement rather than repair; scheduled advisor follow-up to discuss replacement options.
Successfully installed new Moen kitchen faucet with pull-down sprayer in stainless steel sink. Replaced existing dual-handle faucet with high-arc model featuring spot-resistant chrome finish and manual operation.
Responded to no heat call where furnace was not operational. Diagnosed issue as extinguished pilot light due to roof jack being covered with snow, which restricted proper ventilation. Cleared snow from around roof jack and successfully relit pilot, restoring normal heat function.
Responded to client request for kitchen faucet replacement. Consulted with homeowners on various Moen faucet options while examining existing double-basin stainless steel sink with chrome fixtures. Created multiple estimates and the homeowners selected the premium Moen option.
Performed annual furnace tune-up on 1-year-old FRP system. Verified clean air filter, noted beginning accumulation on blower and secondary components, and advised customer to increase filter replacement frequency. Inspected heat exchanger (no compromises found), tested electrical components (all within specifications), and confirmed proper gas pressures and venting. System operated correctly during 15-minute test cycle. Customer reported water softener leakage issue; scheduled follow-up appointment with plumbing specialist.
Responded to warranty call for boiler system leakage. Replaced defective valve but system continues to leak from relief valve with abnormally high pressure (30 psi), indicating potential issues with the auto fill valve. Expansion tank (Amtrol Extrol) may also be malfunctioning. Documented both parts needed and scheduled estimate for complete repair.
Diagnosed ignition failure on IBC boiler serving shop heating system. Verified spark igniter functioning properly but identified faulty gas valve preventing fuel flow. Temporarily restored operation by manually actuating solenoid during ignition sequence. Completed parts order form for replacement gas valve after confirming unit is out of warranty.
Responded to no-heat call for 9-year-old IBC boiler that failed to ignite. Performed comprehensive cleaning of heat exchanger, flame sensor, spark rod, and condensate trap after diagnosing extensive dirt buildup preventing proper operation. Verified proper function of expansion tank and condensate pump. After service, boiler ignited correctly and heat production was restored. Monitored system for 10 minutes to confirm stable operation.
Performed routine furnace tune-up on 16-year-old FRP system. Inspected all components including clean filter, blower, electrical connections, and heat exchanger - all within specifications and no compromises found. System operation verified with 60-degree temperature rise in high fire and proper zone functionality. Noted rusted flange connection on exhaust piping that should be monitored during future maintenance visits.
Responded to no heat call for a 5-year-old Tempstar furnace that failed to start. Diagnosed fault code 6+1 indicating a sticking gas valve. Tapped on gas valve to temporarily restore operation and observed system through multiple heating cycles to confirm diagnosis. Recommended gas valve replacement due to intermittent operation. Visual inspection revealed dust accumulation and cobwebs on pressure switch and control module components.
Responded to no heat call for 30-40 year old LP radiant furnace. Diagnosed multiple critical safety issues including unlit pilot light, corroded thermocouple, holes in the exhaust collector box, and improperly secured gas burner tube (wired on). Recommended full system replacement through comfort advisor due to age and extensive deterioration of critical components.
Responded to warranty service call for recently installed water heater not producing adequate hot water. Diagnosed system operating at only 105°F. Adjusted thermostat settings to increase temperature to 122°F, confirming proper operation with electrical testing equipment.
Responded to no heat complaint for 15+ year old furnace that had resumed operation prior to arrival. Performed multiple power cycling tests with normal operation observed each time. Completed comprehensive tune-up including filter inspection, blower check, condensate line clearance verification, electrical component testing, and heat exchanger inspection - all components found within specifications. Confirmed proper gas pressure with 55-degree temperature rise during extended operational test. System functioning normally upon departure.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions