Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI between December 2025 and January 2026.
The most recent job was on January 19, 2026.
Hurlburt Heating & Plumbing has completed 316 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Performed comprehensive furnace maintenance on Lennox Pulse/Comfort Maker system that was struggling to maintain consistent temperature throughout home. Service included inspection of heat exchanger for defects, cleaning of flame sensor, replacement of plugged filter, and system operation verification. Ultrasonic humidifier was also serviced as part of the complete system tune-up to restore proper heating performance.
Responded to no heat call for boiler system. Diagnosed seized combustion blower motor. Applied lubricant to temporarily restore function. Customer declined replacement part quote and opted to source replacement independently. Advised customer that we do not install customer-supplied parts.
Responded to no heat service call for Lennox furnace. Diagnosed multiple issues: intake pipe frosted due to improper vent termination and air filter severely clogged with white dust from humidifier. Cleared frost from intake, removed obstructed filter, and reset furnace to restore heat. Submitted correction form for installation team to properly terminate venting system.
Responded to service call for 8-year-old furnace that intermittently fails to shut off. Performed diagnostic testing during which unit operated normally but exhibited brief cutout episodes. Conducted complete system service including heat exchanger inspection with no defects found. Determined possible causes include recently replaced but heavily clogged air filter causing limit switch issues and potential malfunction of condensate drain pressure switch connected to gas valve. Recommended more frequent filter replacement and installation of new 0.10 WC pressure switch if problem persists.
Performed standard furnace tune-up on 20-year-old Trane unit. Inspection revealed critical heat exchanger damage including a ~1" crack beneath the burner and a small crack in the secondary heat exchanger. Documented deterioration with photos showing significant metal corrosion and compromised seals. Advised customer that burner assembly requires replacement and recommended full system replacement due to age and condition. Customer will obtain multiple quotes before deciding on replacement.
Responded to service call for toilet leaking from tank supply line. Diagnosed cross-threaded supply line to fill valve on basement toilet. Replaced supply lines for all four toilets in the residence to prevent similar issues, as all fixtures were of similar age and condition.
Responded to a reported gas odor complaint causing resident discomfort. Performed comprehensive inspection of heat exchanger with no cracks or defects detected. Checked attic exhaust system integrity and conducted carbon monoxide testing with zero readings throughout. No gas leak source identified during visit; client will follow up if odor returns.
Responded to no heat/no hot water service call for a 2020 boiler. Diagnosed plugged condensate trap causing water backup. Performed comprehensive tuneup including thorough cleaning of heavily soiled heat exchanger with significant dust accumulation on fins, restored proper system operation, and enrolled customer in rewards program.
Performed preventative maintenance on a 2-year-old Lennox furnace under maintenance agreement. Completed comprehensive inspection of all components with no issues detected. Advised customer about dirty air filter requiring replacement, which they will purchase online.
Responded to no heat call for one-year-old furnace. Upon inspection, the unit started functioning properly after opening the access panel. Performed diagnostic checks on gas pressure, flame sensor, and hot surface ignitor, all showing proper measurements and functionality. Verified adequate heating at all supply registers.
Performed preventative maintenance on a 4-612-4 FA furnace which was found non-operational upon arrival with "failed to light" error. Diagnosed critically low gas pressure (incoming only 3.5" WC). Temporarily adjusted gas valve settings to achieve minimal operating pressure (1.3" low fire, 3.1" high fire), but permanent resolution requires Xcel to address incoming gas supply pressure issue. Customer advised to schedule follow-up with both Xcel and our team for proper gas valve recalibration once supply pressure is corrected.
Identified and resolved water leakage issue from 4-7 furnace caused by drain line blockage. Discovered drain line for furnace/AC system was clogged with lady bugs at air break tee, causing overflow. Cleared obstruction by blowing out and flushing the line, restoring proper drainage. Inspected older furnace, confirmed satisfactory operation with no heat exchanger compromises.
Responded to call regarding Lennox oil furnace making noise and cycling issues. Observed unit operation for 30 minutes but noise complaint could not be replicated. Found and removed severely plugged air filter which was causing the unit to cycle on high limit. Advised customer to record sound if issue recurs for proper diagnosis.
Corrected furnace pitch issue by adding support pads to the rear of the unit. Level tests confirmed proper drainage angle was achieved after adjustment. Required 2-hour service with proper tools to ensure condensate flow.
Responded to no heat complaint after power issue damaged furnace. Diagnosed blown transformer in Daikin furnace system. Replaced transformer and restored heating functionality.
Diagnosed short cycling issue on 1-year-old furnace which was resolved by customer's recent filter change. Performed system inspection, verified proper gas pressure, cleaned flame sensor, and corrected condensate drainage by adjusting furnace pitch to ensure proper water flow toward front drain. System now operating with appropriate 55° temperature rise.
Performed diagnostic service on Bradford White 40-gallon electric water heater that was experiencing operational failure with error code of 3 flashing lights. Determined gas valve had failed and was causing system shutdown. Discussed replacement options with homeowner and scheduled future installation of new water heater.
Performed comprehensive tune-up service on a three-year-old gas furnace. Inspection included heat exchanger examination, condensate drain cleaning, and flame sensor maintenance. System operation verified with all components functioning properly; no issues detected. Unit appears well-installed with proper piping configuration and auxiliary humidifier integration.
Responded to no-heat complaint in commercial building. Investigated zone valve serving Matt's office and found it stuck in closed position. Manually freed valve to restore heat flow. Noted significant mineral deposits on the aging valve (appears to be original to building) and minor dripping. Recommended eventual replacement of 5-1/3" zone valve. Submitted parts request form for future replacement estimate.
Replaced old kitchen faucet with new Moen single-handled model after meeting with customer POC (Sam). Original fixture was deteriorated and difficult to operate; successfully installed and tested new faucet functionality.