Replacing faulty thermostats and repairing broken igniters are common heating repairs in Durand, WI. The harsh winter here puts extra stress on furnaces, heat pumps, and boilers. Scheduling regular maintenance is the best way to avoid breakdowns.
If your heater is ready for a replacement, we’ll help you select a new unit. Today’s furnaces with high AFUE ratings provide exceptionally efficient heating. The correct equipment will save money on heating costs and deliver better comfort.
We work on central ACs and mini-splits. If you want zoned cooling, we recommend going ductless with a heat pump. How large your home is and its layout both influence the process of choosing the best setup.
If your cooling system breaks down, we’re just a call away for AC repair in Durand, WI. Our technicians provide lasting solutions instead of temporary fixes because we prioritize long-term comfort. We even offer emergency HVAC in Durand for refrigerant leaks and other problems that need immediate attention.
If you need extra protection against flooding, we can install a sump pump. You can choose from several types, including pedestal, submersible and battery backup models. Backup systems are especially helpful if your area experiences frequent power outages.
If your home has a hidden water leak, we’ll find it using advanced leak-detection equipment. We understand how moisture issues can lead to mold growth. That’s why we work fast without cutting corners to limit damage and help save money on repairs.
We frequently receive calls to assist with clearing clogs in pipes. We’ll look at the severity and location of the blockage to determine which method is the best option. Clogs are a common problem that is the result of stubborn grease buildup or tree root intrusion.
We are the company to call when you need an electrical panel upgrade. This improvement is often necessary to add new circuits, install high-powered appliances or set up an EV charger.
Our support for generators includes installation, repair, and maintenance. Installing a generator is an excellent way to prevent power loss during outages. You won’t have to stress about losing power or being left in the dark.
We’re the company to call when you need help with electrical, plumbing or HVAC work in Durand. Homes close to the Chippewa River often need sump pump services to prevent basement flooding. Older homes located downtown sometimes require upgrades to their electrical panels to support modern HVAC equipment. Our full suite of solutions makes it simple to keep your home running smoothly.
We bring professional-grade tools to every job and advanced diagnostic equipment. Our high training standards exceed state licensing requirements. All workers go through thorough background checks. We keep our trucks full of common items to fix most HVAC, electrical and plumbing problems on the spot. If we must turn off your water or electricity, we’ll let you know ahead of time. This way, you can plan for the temporary disruption. From installations to repairs and tune-ups, we deliver dependable results on each project. Joining the Hurlburt Family Rewards Club is a great way to enjoy priority service.
Thousands of customers leave us 5-star reviews showing their appreciation for our honest, effective home solutions. Our flexible scheduling simplifies setting up service visits that match your availability.
We love welcoming new customers to the Hurlburt Family! Contact Hurlburt today to access professional solutions for plumbing, electric or HVAC in Durand, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Durand, WI between January 2026 and February 2026.
The most recent job was on February 2, 2026.
Hurlburt Heating & Plumbing has completed 316 jobs in Durand, WI in the last 12 months. The first job there was in October 2015.
Responded to no-heat call for Lennox Pulse furnace. Upon arrival, determined unit was in safety lockout. Reset system and performed heat exchanger inspection, which revealed a significant hole in the primary heat exchanger. Due to carbon monoxide safety hazard, tagged and disabled the furnace. Documented damage with photos showing corrosion and heat exchanger perforation.
Diagnosed 10-ton RTU with no heat condition. Identified combustion blower failing to reach proper speed as root cause. Documented existing unit condition with photos and obtained customer approval for replacement inducer assembly.
Responded to service call for 9-year-old boiler that had power to display screen but was not running, resulting in no heat. Diagnosed issue as depleted batteries in thermostat. Customer provided replacement batteries, which restored system functionality. Boiler is now operating correctly. Noted that system requires cleaning maintenance in the future, but not urgently.
Diagnosed furnace issue where unit wouldn't stay lit. Performed complete inspection of furnace and heat exchanger with no defects found. Determined intermittent fan board failure preventing proper fan activation; documented recommendation for replacement of fan timer board.
Responded to a no-heat service call for a makeup air unit at the headworks building that was previously serviced by Mike B. Diagnosed excessive airflow error code, adjusted airflow pressure settings and reconfigured switch tubing. Monitored unit operation until confirmed stable. Unit is now functioning properly, but recommend ordering a replacement discharge air sensor as preventative maintenance.
Completed replacement of compromised galvanized kitchen sink drain pipe that was causing blockage. Customer had preemptively exposed the wall section, allowing direct access to replace the deteriorated section that runs from the kitchen into the basement. Successfully restored proper drainage functionality.
Identified and repaired a leak at the adapter connecting the water softener to the drain line. Inspection revealed the issue stemmed from the installation configuration where both water treatment tanks were connected to a single drain line using the original softener drain pipe. Properly secured connections to eliminate the intermittent leak that had persisted despite previous repair attempts.
Responded to service call for furnace noise complaint described as "like a train." Discovered loose supply register damper in bedroom which was causing the noise; secured damper in open position. Demonstrated proper air filter replacement technique to homeowner to address difficulties with filter removal. Inspected all other registers and verified system is operating normally.
Responded to no heat complaint for elderly customer with Goodman furnace experiencing intermittent operation. Diagnosed furnace cycling off before reaching setpoint temperature due to faulty control board, confirmed after troubleshooting flame sensor, pressure switches, and thermostat. Also identified non-functional condensate pump. Provided customer with replacement options and noted issue will persist until control board is replaced.
Responded to no heat complaint on aging furnace. Diagnosed water accumulation in pressure switch hose preventing high stage operation. Cleaned components, improved hose slope to ensure proper drainage, and performed comprehensive inspection of heat exchanger and burners. Noted burners showing early signs of contamination and potential need for pressure switch replacement. System now operating correctly with proper combustion and heating capability.
Diagnosed and resolved kitchen sink drainage issue by cutting access hole in wall panel to reach blocked drain pipe at floor level. Cleared obstruction that was causing water to back up into open sewer vent under sink, resulting in leaks when garbage disposal was used. Provided consultation regarding installation of air admittance valve as requested by customer.
Responded to no-heat call at Headworks building. Diagnosed rooftop unit and replaced blower belt. Discovered and thawed ice blockage in pressure switch copper pipe. Successfully restored heating function, though unit has history of recurring issues.
Responded to no-heat complaint where system had been inoperative for 2 days. Diagnostic inspection revealed ice blockage in exhaust vent elbow. Replaced the frozen elbow fitting with a straight pipe section and relocated the elbow to the adjacent pipe, restoring proper exhaust flow and system operation.
Responded to no heat call for 25-year-old system showing pressure switch code. Diagnosed seized combustion blower and installed replacement unit. Identified faulty pressure switch, installed temporary replacement and ordered correct permanent switch. System restored to working condition.
Diagnosed boiler system operating at 30% capacity with outlet temperature of 170°. System functioning as designed but requires cleaning when weather permits; current exterior temperature (-20°F) made immediate cleaning inadvisable. Identified significant heat loss due to structural wall damage allowing cold air infiltration around rim joist; recommended structural repairs to improve heating efficiency. Customer will schedule future cleaning service.
Inspected Myson wall heater that was reported as underperforming. Noted unit has been operating without a filter, likely causing dust accumulation and reduced efficiency. Observed significant gap under nearby door contributing to heat loss. Recommended thorough cleaning of unit in spring to avoid potential complications during cold weather operation.
Responded to no-heat emergency call for inoperative geothermal system with blank display screen. Diagnostic testing revealed failed contactor causing system shutdown. Installed new contactor and verified proper BEO (Balance Energy Output) operation, successfully restoring heat functionality to the system.
Responded to water leak service call for dual issues: leaking toilet shut-off valve in upstairs bathroom and leaking PVC pipe in basement. Tightened the packing nut on the angle stop to resolve the toilet valve leak. Replaced small section of damaged PVC piping in the basement to eliminate the second leak point.
Performed annual maintenance on 8-year-old furnace. Removed burner assembly, inspected heat exchanger with no defects found, cleaned flame sensor, and verified proper system operation. Advised customer about aging igniter that may require replacement in the future and provided estimate for this service.
Responded to no-heat service call for an older oil furnace. Upon arrival, unit was operational with all components appearing to be in good working condition. Conducted thorough inspection of system including blower motor assembly and humidifier installation. Unable to replicate reported issue during visit; suspect possible intermittent transformer malfunction but deferred replacement pending observation of actual failure.
©2026 Hurlburt. All Rights Reserved.