We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Most homes, both north and south of Railroad Avenue, have gas heating due to Colfax’s widespread natural gas access. Our team is skilled with the latest technologies, including gas furnaces, boilers for radiant heating, condensing furnaces, variable-speed air handlers, and more. Our technicians also work with hybrid systems that pair an electric heat pump with a furnace for more efficient heating.
Our Heating Technicians Do It All:
- Heating Repair: Heating troubles can range from inconvenient to downright dangerous. From freezing during a frigid January in Colfax to dangerous gases releasing into your home, call our team to make your home warm and safe again.
- Heating Installation: Professional sizing is crucial when upgrading your heating system. A heater that’s too small or too large will cycle irregularly and experience excessive wear and tear. A well-sized system will be energy-efficient and reliable for many years to come.
- Heating Maintenance: HVAC warranties usually require annual heating tune-ups, and they help you avoid many common repair issues. Clean heating equipment burns fuel more efficiently and costs less to operate. You can save even more as a member of the Hurlburt Family Rewards Program.
While local homeowners once considered cooling a luxury, that isn’t the case any longer. Central AC is a convenient and practical choice for homes with ducts. For those that don’t, ductless AC is a much more effective and efficient alternative to clunky, energy-hogging window units.
We’ll Keep You Comfortable All Summer:
- Cooling Repair: Even minor issues can throw that efficiency out of whack and cause your costs to rise. Our technicians repair all makes and models.
- Cooling Installation: We can customize a wide range of cooling systems for your Colfax home. Zone control is a modern feature that can lower your energy costs. A mini-split is an alternative that doesn’t require ducts.
- Cooling Maintenance: Spring tune-ups result in reliable cooling, lower costs, and better indoor air quality. Our Hurlburt Family Rewards Program includes maintenance, discounts, priority service, and more.
Our plumbers encourage homeowners to schedule an annual plumbing inspection. It’s an opportunity to identify and correct issues early before they get serious. You can also explore the latest plumbing advancements and how they may improve your home.
Electrical inspections can find electrical hazards, code compliance issues, and inefficiencies. If you want to increase your home’s capacity for more appliances and electronics, fix electrical panels, or install new systems altogether, we’re the friendly team to call.
Let Us Maximize Your Home’s Safety and Energy Efficiency:
- Electrical Repair: Electrical problems pose serious risks, including fires, damaged appliances, and shocks. Don’t ignore warm outlets, flickering lights, or frequently tripped circuit breakers.
- Electrical Installation: If you have an older home, you might want to upgrade your outdated electrical panels. A modern panel makes a home safer and more efficient. We can upgrade capacity, add outlets, install lighting, and implement smart home solutions to bring your household into the future.
Hurlburt has been in business since 1959, and we’re proud to provide our services throughout Colfax and the surrounding areas. Our electricians, plumbers, and heating and cooling technicians are among the best in the business. However, we don’t just hire them for their skills and knowledge. We find team members who truly care about serving the Colfax community and improving the lives of local families.
To that end, we always seek to exceed expectations and back our work with a one-year 100% parts and labor warranty. Our company often offers specials, provides free installation estimates, and offers financing to credit-approved and qualified customers.
Want to experience a different kind of electrical, plumbing, and HVAC company in Colfax? Call Hurlburt today!
Hurlburt Heating & Plumbing has completed 20 jobs in Colfax, WI between January 2026 and February 2026.
The most recent job was on February 20, 2026.
Replaced customer-supplied faucet on utility sink in garage, which included installing a new shut-off valve. Inspected existing PVC drainage system and supply lines mounted on wooden wall panel, ensuring proper connection to new fixtures and verifying system functionality after installation.
Diagnosed and repaired a 12-year-old Goodman propane furnace (Model GMSS920402BNAA) that was failing to ignite. Determined the gas valve was faulty despite receiving proper voltage, and replaced it with the correct specification valve. Following installation, leak-tested all fittings, set proper LP gas pressures, and verified complete system operation, restoring heat to the residence.
Conducted inspection of basement plumbing system, focusing on humidifier valve installation. Provided estimate for switching humidifier valve from cold water line to hot water line and repairing the existing cold water line. Documented current setup with photos of the HVAC system and exposed copper piping in ceiling joists.
Completed warranty service work on HVAC system by replacing defective flue collar. Inspected installation in basement mechanical area and verified proper operation of all components after repair. System is now functioning correctly with no further issues.
Diagnosed water leakage from 2-year-old Lennox furnace that customer reported has been occurring since installation. Inspection revealed a cracked cold end header box around the screws and trap connection points due to overtightening during original installation. Documented damage with photos showing water damage on concrete floor beneath unit. Submitted warranty part order form for replacement cold end header box.
Responded to a no-heat call for a Weil-McLain boiler that was reportedly not igniting during heat calls. Upon arrival, system was operational; performed comprehensive inspection including ignitor, heat exchanger, gas pressures, and condensate drain. Multiple test cycles confirmed proper ignition sequence and modulation. Customer had recently refilled LP tank, which likely introduced air/moisture into gas line temporarily causing ignition issues. All components functioning normally at departure.
Completed replacement of 50-year-old leaking tub/shower valve with new Moen Chateau Chrome L2353 system, including valve, spout, and shower head. Installation included Posi-Temp® pressure-balance technology and lever handle for improved functionality and water control. Work required accessing plumbing through wall cavity where significant age-related deterioration was observed around the original plumbing components.
Responded to customer complaint of a leaking washing machine supply line. Discovered improvised valve assembly that was causing the leak. Removed makeshift assembly and installed two new angle stops for laboratory faucet connection and two properly fitted boiler drains for washing machine hookups in basement, resolving the leak issue.
Responded to service call regarding water accumulation around furnace installed in October. Inspection revealed humidifier completely filled with mineral deposits causing water overflow. Also identified improper installation where AC drain line clamp screw had penetrated through flue pipe creating potential safety hazard. Replaced humidifier pad and recommended proper rerouting of humidifier water line to hot water supply with removal of piercing valve.
Diagnosed excessive noise in 13-year-old Lennox natural gas furnace. Inspection of internal components revealed the inducer motor showing significant wear, causing the loud operational noise. Advised homeowner that inducer motor replacement is recommended, but customer opted to source and install replacement parts independently.
Responded to urgent service call for continuously running toilet that was activating pump every 45 minutes. Diagnosed leaking Kohler toilet with failing components. Replaced ball cock assembly and flapper ring to resolve continuous flushing issue and eliminate pump cycling.
Responded to no-heat call for 1-year-old furnace with intermittent operation. Diagnosed control board issue preventing power to inducer motor during heat call. Visual inspection also revealed crack in heat exchanger on classic train spot, documented with photos. Provided homeowner with repair options and scheduled follow-up for potential furnace replacement due to safety concerns.
Responded to customer's no-heat call for a 20-year-old Gibson LP furnace with suspected igniter failure. Previous technician had removed the original igniter, making exact replacement difficult. Although alternative hot rod igniter options were available through Bluon that could be adapted to work with existing mounts, customer preferred waiting for exact replacement part. Provided estimate for correct igniter replacement and informed customer about Monday availability for ordering the part.
Installed new TACO ZONE PUMP W/IFC per approved estimate. Verified proper operation of both zones after installation and adjusted pump speed setting to medium for optimal performance. System is now functioning correctly with all valves and pressure gauges operating as expected.
Responded to customer complaint regarding Kohler two-handled bathtub faucet that would not shut off properly. Diagnosed the issue as a faulty shower valve rather than the previously replaced cartridge. Provided estimate for necessary parts and scheduled follow-up repair to resolve the continuous water flow problem.
Responded to no-heat call and diagnosed non-functioning zone pump for the upstairs. Identified blank display on the 4-year-old Taco OGE Series circulation pump. Inspected thermostats, zone valves, and associated Webstone valves in the hydronic system. Completed diagnostic assessment and provided customer with replacement pump options pending estimate approval for return service.
Responded to service call for 30-year-old AMANA furnace not maintaining adequate heating. Diagnostic inspection revealed severely plugged air filter due to ultrasonic humidifier operation and significant damage to the burner faceplate, including multiple cracks and blow-out conditions. Demonstrated these critical safety issues to resident. Given the age of the unit and extent of heat exchanger damage, replacement was recommended rather than repair. Scheduled follow-up appointment with advisor to discuss replacement options.
Responded to no heat complaint involving 2010 Trane furnace with water leakage. Inspection revealed severely neglected humidifier with deteriorated pad (unchanged for approximately 6 years) causing water leakage. Additionally found extremely dirty blower assembly with damaged filter that had disintegrated due to moisture exposure. Verified humidifier functionality and advised customer to replace humidifier pad.
Responded to service call for inoperative boiler displaying error code F004. Discovered frozen condensate drain was preventing proper operation. Thawed drain line, cleared blockage, and verified proper system function through monitoring complete equipment cycle. Recently installed unit now operating normally.
Responded to no-heat service call for ceiling-mounted unit heater in workshop. Diagnosed improper venting installation using single-wall pipe instead of required B-vent, resulting in rusted/separated exhaust components. Performed temporary repair to restore heat functionality. Return visit scheduled to replace with proper B-vent materials to correct the original installation error.