We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Most homes, both north and south of Railroad Avenue, have gas heating due to Colfax’s widespread natural gas access. Our team is skilled with the latest technologies, including gas furnaces, boilers for radiant heating, condensing furnaces, variable-speed air handlers, and more. Our technicians also work with hybrid systems that pair an electric heat pump with a furnace for more efficient heating.
Our Heating Technicians Do It All:
- Heating Repair: Heating troubles can range from inconvenient to downright dangerous. From freezing during a frigid January in Colfax to dangerous gases releasing into your home, call our team to make your home warm and safe again.
- Heating Installation: Professional sizing is crucial when upgrading your heating system. A heater that’s too small or too large will cycle irregularly and experience excessive wear and tear. A well-sized system will be energy-efficient and reliable for many years to come.
- Heating Maintenance: HVAC warranties usually require annual heating tune-ups, and they help you avoid many common repair issues. Clean heating equipment burns fuel more efficiently and costs less to operate. You can save even more as a member of the Hurlburt Family Rewards Program.
While local homeowners once considered cooling a luxury, that isn’t the case any longer. Central AC is a convenient and practical choice for homes with ducts. For those that don’t, ductless AC is a much more effective and efficient alternative to clunky, energy-hogging window units.
We’ll Keep You Comfortable All Summer:
- Cooling Repair: Even minor issues can throw that efficiency out of whack and cause your costs to rise. Our technicians repair all makes and models.
- Cooling Installation: We can customize a wide range of cooling systems for your Colfax home. Zone control is a modern feature that can lower your energy costs. A mini-split is an alternative that doesn’t require ducts.
- Cooling Maintenance: Spring tune-ups result in reliable cooling, lower costs, and better indoor air quality. Our Hurlburt Family Rewards Program includes maintenance, discounts, priority service, and more.
Our plumbers encourage homeowners to schedule an annual plumbing inspection. It’s an opportunity to identify and correct issues early before they get serious. You can also explore the latest plumbing advancements and how they may improve your home.
Electrical inspections can find electrical hazards, code compliance issues, and inefficiencies. If you want to increase your home’s capacity for more appliances and electronics, fix electrical panels, or install new systems altogether, we’re the friendly team to call.
Let Us Maximize Your Home’s Safety and Energy Efficiency:
- Electrical Repair: Electrical problems pose serious risks, including fires, damaged appliances, and shocks. Don’t ignore warm outlets, flickering lights, or frequently tripped circuit breakers.
- Electrical Installation: If you have an older home, you might want to upgrade your outdated electrical panels. A modern panel makes a home safer and more efficient. We can upgrade capacity, add outlets, install lighting, and implement smart home solutions to bring your household into the future.
Hurlburt has been in business since 1959, and we’re proud to provide our services throughout Colfax and the surrounding areas. Our electricians, plumbers, and heating and cooling technicians are among the best in the business. However, we don’t just hire them for their skills and knowledge. We find team members who truly care about serving the Colfax community and improving the lives of local families.
To that end, we always seek to exceed expectations and back our work with a one-year 100% parts and labor warranty. Our company often offers specials, provides free installation estimates, and offers financing to credit-approved and qualified customers.
Want to experience a different kind of electrical, plumbing, and HVAC company in Colfax? Call Hurlburt today!
Responded to urgent service call for continuously running toilet that was activating pump every 45 minutes. Diagnosed leaking Kohler toilet with failing components. Replaced ball cock assembly and flapper ring to resolve continuous flushing issue and eliminate pump cycling.
Responded to no-heat call for 1-year-old furnace with intermittent operation. Diagnosed control board issue preventing power to inducer motor during heat call. Visual inspection also revealed crack in heat exchanger on classic train spot, documented with photos. Provided homeowner with repair options and scheduled follow-up for potential furnace replacement due to safety concerns.
Responded to customer's no-heat call for a 20-year-old Gibson LP furnace with suspected igniter failure. Previous technician had removed the original igniter, making exact replacement difficult. Although alternative hot rod igniter options were available through Bluon that could be adapted to work with existing mounts, customer preferred waiting for exact replacement part. Provided estimate for correct igniter replacement and informed customer about Monday availability for ordering the part.
Installed new TACO ZONE PUMP W/IFC per approved estimate. Verified proper operation of both zones after installation and adjusted pump speed setting to medium for optimal performance. System is now functioning correctly with all valves and pressure gauges operating as expected.
Responded to customer complaint regarding Kohler two-handled bathtub faucet that would not shut off properly. Diagnosed the issue as a faulty shower valve rather than the previously replaced cartridge. Provided estimate for necessary parts and scheduled follow-up repair to resolve the continuous water flow problem.
Responded to no-heat call and diagnosed non-functioning zone pump for the upstairs. Identified blank display on the 4-year-old Taco OGE Series circulation pump. Inspected thermostats, zone valves, and associated Webstone valves in the hydronic system. Completed diagnostic assessment and provided customer with replacement pump options pending estimate approval for return service.
Responded to service call for 30-year-old AMANA furnace not maintaining adequate heating. Diagnostic inspection revealed severely plugged air filter due to ultrasonic humidifier operation and significant damage to the burner faceplate, including multiple cracks and blow-out conditions. Demonstrated these critical safety issues to resident. Given the age of the unit and extent of heat exchanger damage, replacement was recommended rather than repair. Scheduled follow-up appointment with advisor to discuss replacement options.
Responded to no heat complaint involving 2010 Trane furnace with water leakage. Inspection revealed severely neglected humidifier with deteriorated pad (unchanged for approximately 6 years) causing water leakage. Additionally found extremely dirty blower assembly with damaged filter that had disintegrated due to moisture exposure. Verified humidifier functionality and advised customer to replace humidifier pad.
Responded to service call for inoperative boiler displaying error code F004. Discovered frozen condensate drain was preventing proper operation. Thawed drain line, cleared blockage, and verified proper system function through monitoring complete equipment cycle. Recently installed unit now operating normally.
Responded to no-heat service call for ceiling-mounted unit heater in workshop. Diagnosed improper venting installation using single-wall pipe instead of required B-vent, resulting in rusted/separated exhaust components. Performed temporary repair to restore heat functionality. Return visit scheduled to replace with proper B-vent materials to correct the original installation error.
Responded to no-heat call for 24-year-old residential furnace exhibiting pressure switch code. Diagnosed system, cleared condensate drains, and reset unit, successfully restoring heat operation. System is now functioning but may require future service due to age-related issues.
Responded to no heat call for Weil-McLain boiler system. Discovered small beehives obstructing the intake/exhaust venting and a dirty flame sensor. Cleaned accessible obstructions from venting and thoroughly cleaned flame sensor, restoring proper ignition sequence. System now operating correctly with heat production confirmed.
Responded to no heat call for furnace installed in 2023. Diagnosed issue with pressure switch preventing system startup. Successfully unstuck pressure switch, allowing unit to resume normal operation. System tested and verified proper functionality; customer provided with replacement estimates for future consideration.
Performed comprehensive preventive maintenance on Bryant furnace system located in basement utility area. All operational parameters were verified within manufacturer specifications. Visual inspection revealed no issues with unit performance or installation. System is functioning properly with no repairs required.
Performed annual maintenance on 3-year-old Furnace FRP system. Inspected heat exchanger with no issues found, cleaned and inspected blower, checked all electrical connections, and verified clear condensate lines with proper drainage. Tested system operation for 20 minutes confirming proper gas pressures and venting with a 55°F temperature rise. Filter maintained by customer. All system parameters within specifications per tune-up documentation.
Responded to service call for intermittent furnace operation issue on a 10-year-old Goodman system. Diagnostic testing revealed flame sensor was severely fouled, causing flame sensing failures and resulting in the furnace tripping on flame sense code. Performed complete system tune-up including thorough cleaning of flame sensor, verification of proper condensate drainage, and inspection of heat exchanger (noted minor rust spots but no significant concerns). System was tested after service with proper operation confirmed, achieving 50° temperature rise. Discussed future AC installation options with homeowner.
Responded to no heat call for Lennox furnace displaying error code 291 (restricted airflow). Diagnosed heavily clogged filter with fine white dust likely from ultrasonic humidifier as the cause of the airflow restriction. Removed and replaced filter, which cleared the fault code. Tested system operation for 15 minutes at maximum heating rate with proper 60-degree temperature rise, confirming normal function. Advised customer to discontinue humidifier use temporarily and replace filter monthly.
Responded to no heat call for a system with a limit code and non-functioning blower. Identified that the new blower motor installed last week had a burned out low speed winding due to incorrect capacitor installation (10 mfd vs. required 5 mfd). Replaced with correct 5 mfd capacitor and rewired motor to utilize medium speed winding as a temporary solution until replacement motor arrives.
Installed new Meno gas regulator (1/2" or 3/4") and successfully converted system to 2-pound operation per approved estimate. Coordinated with gas company to verify proper pressures and added Maxis control regulator to boiler with appropriate pressure settings. All systems verified operational with correct gas pressure parameters.
Responded to customer concern that recently installed furnace was not maintaining adequate heat. Upon inspection, discovered partially closed dampers in living room vents and thermostat set to "comfort" mode causing more frequent cycling. Opened dampers in living room vents and educated homeowner on thermostat comfort settings. Activated fan to improve air circulation throughout home to address customer's temperature perception issues. All equipment functioning properly with no mechanical deficiencies identified.