Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Performed preventive maintenance on approximately 20-21 year old Bryant R-22 air conditioning system. Connected gauges and verified refrigerant pressures within acceptable range. Cleaned condenser coils and inspected electrical components including capacitor and contactor. Capacitor reading 45/5 MFD with good values; contactor drawing 0.38 amps on low voltage coil. Inspected evaporator coil which showed no issues with 19-degree temperature drop across coil. Air filter recently changed and clean. Advised customer of system age, R-22 refrigerant phase-out considerations, and recommended against major repairs should failures occur in the future due to age of equipment. System currently operating within normal parameters and cooling properly.
Completed comprehensive air conditioning preventive maintenance on Lennox HVAC system. Performed full system inspection including condenser cleaning, verified ECM/inverter operation, opened air handler to confirm all components were clean and functioning properly, and cleared condensate drain line. Noted air filter was becoming dirty after approximately one year of use; customer declined replacement and opted to source and install filter independently. All system parameters verified within manufacturer specifications with unit cooling properly upon completion.
Performed preventive maintenance on both furnace and air conditioning system. Inspected and cleaned furnace components including flame sensor and condensate trap. Checked ignitor operation, safety switches, air filter condition, gas pressure, inducer motor, blower assembly, and heat exchanger integrity. Identified rusted burners causing hard ignition and difficult lighting. Cleaned outdoor condenser coil and performed routine inspection of air conditioning components despite adverse weather conditions limiting full system evaluation. Customer reported squealing noise from indoor unit during AC shutdown cycle. Provided estimate for burner replacement to resolve ignition issues and restore proper furnace operation.
Completed comprehensive air conditioning maintenance and tune-up on a 17-year-old system. Performed diagnostic testing using digital multimeter and temperature probe, verifying proper system operation and electrical readings. System found to be functioning within normal parameters; capacitor previously replaced last year remains in good condition.
Responded to a no hot water condition on a tanked water heater. Upon arrival, found the thermostat had tripped and was producing a humming noise after reset attempts. Diagnosed faulty thermostat causing repeated tripping. Removed access panel, disconnected power, and replaced the defective thermostat with a new unit. Reconnected all electrical wiring including ground, black, and red wires to proper terminals. Restored power and verified proper operation of the water heater with no abnormal sounds or tripping issues.
Responded to a leak reported under a recently installed bathroom faucet at the shut-off valve connection. Upon inspection, discovered that supply lines were only hand-tightened and both sink faucets were improperly secured to the mounting surface. Properly tightened all supply line connections to manufacturer specifications and secured both faucet units to eliminate movement and prevent future leaks.
Performed comprehensive air conditioning preventive maintenance including condenser coil cleaning and thorough inspection of all electrical components. Verified capacitor and contactor readings were within manufacturer specifications, confirmed air filter was clean, and measured a proper 20-degree temperature differential across the evaporator coil. System operating efficiently with no deficiencies noted.
Responded to reported water leaks in bathroom and basement areas. Upon inspection, identified failed wax ring seal at toilet base causing water infiltration at floor-to-wall junction. Removed and reset toilet with new wax ring to restore proper seal and eliminate leak. Inspected basement drainage piping for reported drip from PVC pipe connected to bathroom plumbing system.
Completed comprehensive AC tune-up on 9-year-old system as part of maintenance agreement. Performed thorough inspection of all air conditioning components, cleaned evaporator coil, verified proper operation of all system controls, and installed new air filter. All components operating within normal parameters with no issues identified at time of service.
Completed comprehensive AC maintenance including coil cleaning and electrical inspection. Upon testing, unit showed low temperature split of approximately 13° and refrigerant pressure measured at only 30 psi, indicating R-22 system is significantly undercharged. Discussed findings with homeowner regarding refrigerant deficiency and offered service advisor consultation for repair options, which was declined due to budget constraints. Unit currently operational and providing mild cooling despite low refrigerant charge.
Completed comprehensive plumbing inspection of residential property, including evaluation of all fixtures, water quality testing, and water heater assessment. Water hardness tested at 3 GPG, all toilets inspected and found in clean working condition, and water heater identified as approximately 22 years old but currently operational. Customer expressed interest in reverse osmosis system installation; provided information regarding RO system options and will prepare estimate for future installation.
Performed seasonal maintenance and inspection on 2021 Rheem air conditioning system and 2021 Rheem 80% efficiency gas furnace. The air conditioning unit was cleaned, inspected, and tested with all components operating normally and no faults detected at time of service. During furnace inspection, observed notable white powder/residue accumulation on top of burners. Property occupants indicated thermostat is maintained at 50°F during extended absences. Documented burner residue for future monitoring as this condition may indicate moisture/condensation exposure or combustion byproduct buildup. Recommended verification of proper venting and combustion conditions during next service visit if residue continues to increase. Advised property occupants to maintain minimum thermostat setting of 60°F rather than 50°F during winter months to reduce potential condensation issues. Property occupants will have flue pipe inspected by third party next month for possible holes or connection issues. Fol
Responded to service call for furnace issue. Upon arrival, replaced faulty limit switch with new component and verified system operation. All safety controls tested and confirmed functioning properly. Previously installed control board remained in unit as it was functioning correctly, and original board was removed and provided to customer as backup. System cycled normally through complete heating operation with no error codes. Unit left in proper working order with all components operating within manufacturer specifications.
Installed two new hose bibs on the property per approved estimate. Relocated front hose bib six inches up the wall, drilling through exterior siding to accommodate new positioning with exposed interior plumbing connection. Installed rear hose bib under kitchen area, connecting to existing exposed half-inch copper supply lines beneath kitchen faucet with dedicated shut-off valve for winterization purposes.
Responded to no hot water call and diagnosed 15+ year old 40-gallon gas water heater with pilot light failure and active leaking at the bottom of the tank. Due to age of unit and severity of leak, provided estimate for replacement with 50-gallon power vent water heater. Documented existing equipment condition with photos for customer records.
Responded to no hot water complaint on 50-gallon power vent natural gas water heater. Upon arrival, found unit cycling vent motor but failing to heat water. Discovered thermostat set to 160°F, which likely caused thermal cut-off (TCO) to trip. Identified significant corrosion on inlet and outlet connection ports allowing water intrusion into pressure switch port, compromising unit operation. Reset TCO and restored hot water functionality. Adjusted thermostat setting down to recommended 120°F to prevent future overheating issues. Documented corrosion damage with photographs showing deteriorated pipe connections and mineral buildup on tank top. Provided replacement estimates to homeowner due to advancing corrosion and compromised water heater integrity. Coordinated follow-up appointment for acid neutralizer system evaluation to address potential water chemistry issues contributing to accelerated corrosion.
Performed comprehensive AC tune-up on York Stellar Series system. Upon inspection, discovered multiple issues requiring attention: blower wheel exhibiting excessive play, run capacitor reading 4.3uf against specification of 7.5uf, evaporator coil nearly completely blocked with debris, and outdoor contactor showing signs of pitting with low resistance reading of approximately 10 ohms. Air filter found in clean condition. Conducted routine electrical inspection of outdoor condensing unit with all other components testing within acceptable parameters. System operational testing revealed adequate performance with 20-degree temperature split across evaporator coil. Measured refrigerant pressures indicated low charge, potentially affected by restricted evaporator coil but more likely due to actual refrigerant loss given continued cooling performance. Recommended obtaining estimates for evaporator coil cleaning, contactor replacement, and blower motor replacement. Also advised considering sys
Installed two customer-supplied bathroom faucets in upstairs bathrooms. Removed existing faucets, connected new chrome two-handle faucet assemblies with supply lines and drain assemblies, and tested for proper operation and leaks. All fixtures are functioning correctly with no visible leaks at connections.
Responded to no cool complaint on PTAC unit in room 309. Upon arrival, determined thermostat was no longer communicating with the unit. Reprogrammed PTAC to operate using the membrane control panel on the unit itself, bypassing the failed thermostat connection. Unit now functioning properly with manual controls operational.
Completed installation of elongated 17-inch white wood toilet seat and lower level lavatory faucet as requested. Removed existing bidet unit and replaced original toilet seat with upgraded wood construction seat meeting specified dimensions. Successfully installed new lavatory faucet in lower level bathroom, ensuring proper water supply connections and testing for leaks.