Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Completed comprehensive plumbing inspection of residential property, examining water treatment system components including three-stage filtration tanks with control valves and electrical connections, as well as sump pump basin and drainage infrastructure. Conducted visual assessment of all accessible plumbing systems, copper piping, and utility connections to verify proper operation and identify any maintenance concerns.
Completed Family Rewards cooling maintenance visit on Lennox HVAC system as part of recurring preventative maintenance agreement. Performed comprehensive air conditioning tune-up inspection prior to property transfer to new owners. Replaced air filter with customer-supplied filter and verified evaporator drain line was flowing properly. Cleaned outdoor condenser coil which showed moderate dirt accumulation. Inspected all electrical connections and components, finding capacitor testing at acceptable levels. System operational check confirmed proper performance with 20-degree temperature split across evaporator coil, indicating adequate cooling capacity and refrigerant charge.
Responded to no hot water complaint affecting entire home. IBC tankless water heater model SFT199 displayed error code F004 indicating ignition failure. Performed system reset which successfully restored unit operation. Cleaned condensate trap and drainage system to ensure proper function. Inspected electrical connections and control board, noting potential electrical board degradation as possible cause of error code. Unit operational at time of departure with hot water restored throughout home. Advised monitoring for recurring error codes that may indicate need for control board replacement.
Completed annual maintenance agreement service on 19-year-old Carrier air conditioning system and Fujitsu mini-split unit. Performed comprehensive tune-up including cleaning of condenser coils, inspection of electrical connections, refrigerant level verification, and airflow testing on both systems. All components were found operating within normal parameters with no deficiencies identified at time of service.
Responded to a no-cooling call on a 2000 Nordyne furnace and air conditioning system. Upon arrival, found equipment located in basement accessed via trap door with standing water, heavy insect activity, and strong sewage odor creating unsafe and unsanitary working conditions. Furnace was powered off at service switch and evaporator coil access panel had been previously removed. Restored power to system and observed control board displaying two flashing LEDs with no identifiable fault pattern. System remained non-responsive with indoor blower failing to energize and outdoor condensing unit not starting despite thermostat call for cooling. Initial inspection revealed critically low refrigerant levels and equipment in severely deteriorated condition. Due to hazardous work environment including sewage contamination and insect infestation, full diagnostic procedures could not be safely completed. Attempted to contact property owner to report conditions but received no response. Documented c
Responded to callback regarding recently installed water softener producing slimy water with salt taste. Tested water at garage sink confirming soft water output, tested well water showing 4 gpg hardness and 43 TDS. Flushed water softener system and adjusted settings to optimize performance: reduced salt usage from 10 lbs to 7.5 lbs per regeneration cycle, increased regeneration interval from 14 to 17 days based on calculated water usage of approximately 100 gallons per day and 24k grain capacity. Verified hardness setting calibrated correctly at 4 gpg to match well water characteristics. Advised homeowner to monitor system performance over next two weeks to confirm adjustments resolved the issue. Documented neutralizer model number for calcite media verification.
Responded to no cooling complaint on 10+ year old Carrier outdoor unit at rental property. Upon arrival, found condenser fan motor operating but compressor failing to start. Diagnosed failed run capacitor preventing compressor from energizing. Tested remaining electrical components and confirmed proper operation. Replaced defective dual run capacitor with OEM equivalent. Cycled system on and verified compressor startup and operation. Measured refrigerant subcooling and confirmed readings within manufacturer specifications, indicating proper charge and system performance. Unit restored to normal cooling operation.
Performed comprehensive rooftop unit tune-up including replacement of air filters and inspection of all system components. Thermostat verified operational at 68°F with proper display function. Coil cleaning was not performed due to absence of exterior water source. All components checked and found operating within normal parameters with no deficiencies identified.
Completed Family Rewards Program cooling maintenance visit on Carrier HVAC system. Performed comprehensive tune-up including cleaning of routine components, testing all electrical and mechanical parts, and inspecting air filter. Verified proper operation of both indoor furnace/air handler unit and outdoor condenser unit, confirming system is running efficiently and ready for continued service.
Completed comprehensive plumbing inspection of residential property. Inspected bathroom fixtures including sink, faucet assembly with dual cross-handle controls, and drain system, confirming proper operation and no visible leaks. Evaluated mechanical room plumbing connections, copper supply lines, and utility area installations to ensure compliance with plumbing standards and verify system integrity.
Completed comprehensive AC tune-up on 26-year-old air conditioning system under Family Rewards Program maintenance agreement. Cleaned outdoor condenser unit, repaired rodent-damaged electrical wiring, and performed full system diagnostics with pressure testing to verify proper refrigerant levels and component operation. System tested and confirmed cooling effectively with all components functioning within manufacturer specifications.
Completed comprehensive AC tune-up and maintenance inspection. Verified system operation and found clean filter. Discovered minor oil leak at blower motor with intact cap. Performed outdoor condenser unit cleaning and component inspection, repaired damaged wiring from animal activity. Conducted refrigerant pressure and temperature diagnostics revealing elevated superheat and subcooling levels with 15-degree temperature split, indicating potential low refrigerant charge and general system wear. Provided replacement recommendations for blower motor, condenser fan motor, and contactor to address aging components and optimize future performance.
Completed comprehensive annual air conditioning tune-up on 8-year-old Gibson HVAC system as part of maintenance agreement. Performed full system inspection of indoor air handler unit and outdoor condensing unit, cleaned routine components, replaced air filter, and tested all operational components to verify proper system performance. All equipment found operating within manufacturer specifications upon completion of preventive maintenance service.
Completed plumbing inspection for friends and family service. Identified 50-gallon water heater actively leaking, unit is over 20 years old and beyond serviceable life. Documented existing plumbing conditions including under-sink drainage system and supply lines. Provided estimate for replacement 50-gallon water heater installation.
Completed comprehensive AC tune-up including full system inspection of indoor and outdoor units. Addressed homeowner concern regarding rattling noise from outdoor unit by rinsing condenser coils, inspecting electrical components, and identifying loose fan cover which was resecured to eliminate noise. Verified evaporator drain line draining properly and confirmed system operating efficiently with 22° temperature split across evaporator coil. Noted air filter overdue for replacement (over one year) and advised homeowner to replace soon for optimal system performance.
Responded to water pump short cycling issue. Inspected Well-X-Trol pressure tank, associated plumbing connections, pressure switch, and Culligan water softener system. All interior components, valves, fittings, and controls tested and found operating within normal parameters. Determined short cycling issue originates from well system components outside scope of indoor plumbing equipment. Advised customer to contact well installation contractor for further diagnosis and repair of well pump or underground components causing cycling malfunction.
Responded to service call following whole-home mold remediation where air duct cleaning company identified buildup on HVAC evaporator coil. Upon arrival, inspected R-22 air conditioning system and confirmed mold testing had detected growth inside both the evaporator coil and furnace components. Assessed cleaning requirements and determined that standard maintenance procedures would be insufficient to address confirmed mold contamination within the coil assembly. Explained to homeowners that proper remediation would require specialized antimicrobial products and procedures beyond standard HVAC maintenance capabilities. Documented internal system components with photographs showing circuit boards, refrigerant lines, and coil housing. Clarified that removing and externally cleaning the evaporator coil as initially expected was not feasible given the extent of contamination and age of R-22 equipment. Scheduled follow-up appointment with service advisor to discuss comprehensive replacement
Performed comprehensive preventive maintenance on residential air conditioning system and tankless water heater. Cleaned outdoor condenser coil, inspected all electrical components and connections, verified proper operation with 20-degree temperature differential across evaporator coil. Confirmed air filter clean and condensate drain line clear with no obstructions. Completed descaling flush on tankless water heater, removing minor scale buildup from heat exchanger. Flushed unit thoroughly and verified proper operation following service. All systems tested and confirmed operating within manufacturer specifications. Documented equipment condition with photographs. Provided estimate for expanded maintenance plan coverage.
Completed comprehensive tune-up on 8-year-old furnace and air conditioning system that had never been previously serviced. Performed thorough inspection of all furnace components including blower assembly, evaporator coil, and heat exchanger—all found to be in proper working condition with no issues identified. Cleaned evaporator coil and verified clear airflow. Proceeded to outdoor condenser unit where condenser coil was rinsed and cleaned. Removed condenser fan motor and cleared accumulated leaves and debris from bottom of unit. Inspected all electrical connections and components at both indoor and outdoor units—all connections secure and functioning properly. Measured temperature split across system and confirmed 17-degree differential, indicating proper refrigerant charge and system performance. All systems tested and operating within manufacturer specifications upon completion.
Responded to water leak call at residential property while homeowners were away. Upon inspection of basement plumbing system, discovered crack in main sewer cast iron pipe as reported, along with multiple additional holes in cast-iron and galvanized piping. Assessment revealed extensive corrosion and deterioration throughout aging cast-iron drain system, with visible oxidation and structural compromise at multiple joints and pipe sections. Water supply lines also exhibited significant wear and aging characteristics requiring attention. Documented all findings with photographs showing corroded metal piping, deteriorated pipe surfaces, and overall condition of basement plumbing infrastructure. Contacted homeowner to report comprehensive findings and coordinated follow-up appointment for detailed estimate on complete cast-iron system replacement and waterline repairs.