Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to reports of PVC piping leaking in multiple locations throughout the basement. Upon arrival, conducted thorough inspection to locate source of water intrusion. Initial assessment revealed active leak originating from basement level with moisture tracking upward through structure. Performed detailed investigation which required opening a section of wall on the main level to access concealed plumbing. Inspection revealed compromised cold water supply line feeding toilet fixture. The braided flex supply line connection showed signs of failure, resulting in water seepage behind wall cavity and subsequent damage to surrounding building materials including insulation, drywall, and flooring. Isolated water supply to affected area and removed failed supply line. Installed new braided stainless steel flex connector to cold water supply feeding toilet. Verified all connections were secure and leak-free. Restored water supply and pressure-tested repair to ensure proper function. Conf
Responded to no-cooling complaint at commercial property where upstairs rooms were not maintaining temperature on hot days. Upon arrival, confirmed adequate airflow at supply vents and that filter had been recently replaced. Inspected outdoor condensing unit and found heavy dirt accumulation and severely clogged condenser coil. Shut down system and performed electrical component inspection; capacitor tested within acceptable range. Thoroughly cleaned and rinsed condenser coil, removing significant debris buildup that was restricting airflow and reducing heat transfer efficiency. Restarted system and performed refrigerant pressure check with manifold gauges; pressures indicated proper charge levels. Verified unit returned to normal cooling operation after cleaning. Identified thermostat location issue as contributing factor to comfort complaints—thermostat positioned in downstairs break room which runs cooler than larger upstairs spaces, causing premature system shutdown before upstairs
Removed end-of-life garbage disposal unit and associated mounting hardware from kitchen sink drain system. Installed new sink strainer basket in disposal opening and reconfigured drain plumbing with white PVC P-trap assembly to establish proper drainage without disposal unit. Tested all connections for leaks and verified proper drain flow upon completion.
Responded to no cooling complaint with system blowing warm air and indoor temperature at 78 degrees. Found condenser coil heavily soiled with debris, restricting airflow and reducing system efficiency. Performed thorough condenser coil cleaning by rinsing accumulated dirt and debris from exterior surfaces. Conducted maximum cooling performance test, measuring an 18-degree temperature split across the evaporator coil, which falls within acceptable range. Verified refrigerant charge by checking subcooling levels, which measured slightly low but determined no adjustment necessary due to adequate temperature split indicating proper system operation. System restored to normal cooling operation following condenser coil cleaning.
Responded to no-cool condition on 2001 Armstrong R-22 central air conditioning system. Upon arrival, confirmed outdoor compressor unit was not engaging. Performed diagnostic testing and identified failed dual-run capacitor on compressor circuit. Capacitor tested significantly below manufacturer specifications at 0/3.7 MFD versus rated 30/5 MFD, preventing compressor operation. Replaced defective capacitor with properly rated unit, restored system to operational status, and verified cooling cycle. Advised homeowner that given the age of the R-22 system and potential for future component failures, replacement options may warrant consideration for long-term reliability.
Completed comprehensive AC tune-up and clean-and-check service on 6-year-old Lennox system. Inspected all components including indoor furnace unit and outdoor condenser, verified proper operation of electrical connections, refrigerant lines, condensate drainage, and airflow systems. All equipment found operating within normal parameters with effective cooling performance and no deficiencies noted at time of service.
Responded to no cooling complaint on 1999 Lennox air conditioning system with reported buzzing noise from outdoor unit. Upon inspection, diagnosed failed run capacitor causing compressor malfunction. Replaced defective capacitor with new component, restored power, and verified proper system operation with 15-degree delta T across evaporator coil, confirming adequate cooling performance.
Responded to no cooling complaint on 9-year-old residential AC system. Found outdoor unit not operating despite contactor clicking. Diagnostics revealed tripped breaker at electrical panel, which occurred after thermostat battery replacement. Reset breaker, restored power to outdoor unit, and verified compressor and condenser fan motor operation. Tested all system components and confirmed proper operation with 20-degree temperature split across evaporator coil.
Responded to no cooling complaint on mini split system. Found unit low on refrigerant charge. Performed leak check at service ports with electronic detector showing no leaks at connection points, indicating refrigerant loss occurring elsewhere in system. Added refrigerant charge and UV dye to system for future leak detection. Verified proper cooling operation with supply air temperature reading of 46.9°F and confirmed system pressures and superheat readings within acceptable range at 15.9 PSIG with 126.9°F superheat on R-410A refrigerant. System restored to normal cooling operation.
Responded to no cooling complaint on 14-year-old Trane air conditioning system. Upon arrival, found outdoor unit humming but condenser fan not operating. Performed diagnostic testing of electrical components and determined dual run capacitor had failed completely, preventing fan motor operation while compressor attempted to run. Replaced failed capacitor with new unit, rinsed down condenser coil and exterior components, reassembled unit, and verified proper system startup and operation. All components now functioning as designed with normal cooling restored.
Responded to callback for water leakage from air handler in attic following previous drain line service. Upon inspection, discovered evaporator coil drain pan was improperly pitched, causing water to overflow from the backside after only 1.5 bottles of water. Corrected issue by lifting the return end of the air handler and installing additional support pads under both the unit and evaporator pan to achieve proper drainage slope. Verified repair by testing with two bottles of water, confirming proper drainage flow. Unit operating correctly with no further leakage. Photos documented completed work.
Responded to downstairs kitchen garbage disposal not working. Upon inspection, determined unit had no power supply. Unable to contact customer on-site to discuss findings and repair options. Documented conditions with photos and prepared estimate for either disposal repair or complete removal with sink drain reconfiguration per customer's preference.
Responded to no cooling complaint on 4-year-old Lennox EL18XCVS036 variable-speed air conditioning system. Upon arrival, verified unit was completely non-operational with no cooling output throughout home. Performed comprehensive diagnostic evaluation of outdoor unit. Measured incoming line voltage at 244-245 VAC and control voltage at 27.4 VAC, both within acceptable parameters. Confirmed cooling demand present on control board (display showing -- 2 code) and verified contactor was properly engaged. Despite proper electrical supply and control signals, compressor remained idle with no attempt to start. Conducted compressor winding resistance testing using digital multimeter. Measured 1 ohm resistance across U-V, V-W, and U-W terminals, indicating balanced windings. Tested insulation resistance to ground on all three phases, recording open line (OL) readings, confirming compressor windings were electrically sound with no ground faults. Based on these measurements, determined compres
Responded to no cooling complaint on one-year-old residential air conditioning system. Upon arrival, confirmed outdoor condenser fan motor was completely seized and inoperative, causing unit to overheat with no airflow across condenser coil. Successfully freed seized motor shaft, restoring rotation and proper operation. System tested and verified cooling normally with proper airflow and temperature differential. Advised customer that condenser fan motor requires warranty replacement due to premature failure and placed parts order for permanent repair. Unit operational and providing adequate cooling until warranty motor arrives for installation.
Performed preventative maintenance tune-up on 4-year-old Lennox air conditioning system. Inspected indoor unit and found air filter and blower assembly in clean condition. Evaporator coil was clean but showed minor water accumulation in drain pan. Outdoor condensing unit was heavily soiled with debris. All electrical components tested within manufacturer specifications. Cleared evaporator drain line blockage and thoroughly cleaned condenser coil. Conducted operational test with 15-minute runtime, confirming proper system function with 15-18 degree temperature split across evaporator coil, meeting performance standards.
Responded to water leak at treatment tower system where both drain fittings were found cracked and failing. Removed and replaced both drain adapter fittings, re-taped PEX adapters to ensure proper seal, and noted that supply lines connecting to tanks may be under warranty from original installation. System tested and leak resolved.
Responded to service call for recently installed toilet seat that was not secured properly. Upon inspection, confirmed toilet seat mounting bolts were not locked into position, causing seat to shift and remain loose. Properly secured toilet seat by locking mounting hardware into place, ensuring stable installation and eliminating movement.
Responded to no cooling condition on residential air conditioning system. System was low on refrigerant charge. Added approximately 1.5 pounds of R410a refrigerant along with UV leak detection dye to identify source of refrigerant loss. After recharge, system achieved 16° temperature split across evaporator coil and resumed cooling operation. Superheat readings remained lower than optimal, indicating possible restriction in refrigeration circuit requiring future diagnosis. Customer advised that leak detection dye will help locate refrigerant leak point during next service visit when issue recurs.
Responded to clogged kitchen sink where homeowner had attempted snaking but could not reach the blockage. Plugged drain and performed professional drain snaking procedure to clear the obstruction at depth beyond homeowner's equipment reach. Successfully restored proper drainage to kitchen sink.
Responded to no hot water complaint on tankless water heater unit. Upon inspection, diagnosed faulty IBC SFT 199 control board causing system failure. Removed defective board and installed warranty replacement IBC SFT 199 board. Reconnected all electrical connections and wiring harnesses to new control board. Powered up unit and performed operational testing of all functions including ignition sequence, burner operation, and temperature control. Verified proper communication between control board and system components. Confirmed hot water delivery throughout home and unit operating within manufacturer specifications.