Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Completed comprehensive AC tune-up on 5-year-old system under maintenance agreement. Performed exterior coil cleaning on condensing unit, verified all electrical connections and amperage readings within manufacturer specifications, and confirmed air filter in excellent condition. System operating properly with no deficiencies noted.
Responded to no cooling complaint with evaporator coil and suction line freeze-up. Diagnosed system low on R-22 refrigerant causing reduced cooling capacity and ice formation on indoor coil. Given the unit's age (1999 model) and use of phased-out R-22 refrigerant, recommended system replacement and coordinated with sales team to provide equipment options to the homeowner.
Responded to service call for leaking shut-off valve located before the water meter. Upon inspection, confirmed active leak at valve assembly and identified moisture damage on surrounding wooden panel. Evaluated valve condition and determined replacement necessary to prevent further water loss and property damage. Prepared comprehensive estimate for valve replacement work, which will require coordination with municipal water department for street-side shut-off during installation. Documented existing conditions with photographs and forwarded estimate to customer for approval before scheduling.
Responded to service call for Lennox mini-split system requiring refrigerant recharge to restore cooling capacity. Successfully refilled unit to factory specifications to provide immediate comfort while scheduling follow-up appointment for comprehensive system repair and diagnosis of underlying refrigerant loss.
Responded to emergency call for musty odor and sewer smell in room 407. Upon inspection, identified failed trap adapter gasket on vanity drain assembly that had displaced outside the slip nut connection, causing leak and odor infiltration. Disassembled P-trap configuration, removed defective gasket, and installed new trap adapter gasket with proper seating within slip nut. Reassembled drain assembly, tightened all compression fittings to manufacturer specifications, and tested system for leaks. Verified proper drainage flow and confirmed elimination of sewer gas escape. Documented repair with photographic evidence of completed installation.
Performed second-opinion no-cool evaluation on a 1999 Trane split A/C system with furnace. With outdoor ambient temperature at 95°F, measured system pressures at -4.5 psig suction and 54.5 psig liquid on R-22 refrigerant, indicating critically low refrigerant charge and near-empty system. Findings confirmed previous contractor's assessment of severe refrigerant loss and inability to maintain cooling capacity. Given the system's age (over 20 years), obsolete R-22 refrigerant, and extent of refrigerant depletion, recommended full system replacement rather than repair. Coordinated with comfort advisor to schedule equipment replacement consultation.
Responded to a backup issue at the floor drain caused by a malfunctioning ejector pump. Upon inspection, identified a failed float switch and partial obstruction in the pit drain outlet line. Cleared the blockage from the drain outlet, replaced the defective float switch with a new unit, and installed a 2-inch check valve to prevent backflow. System tested and restored to proper operation with no further backup issues observed.
Responded to no cool call with outdoor unit squealing and condenser fan not operating. Upon arrival, found condenser fan motor locked up and seized. Freed up motor shaft to restore temporary operation and system cooling. Diagnostic testing revealed capacitor out of specification on hermetic terminal, contactor showing pitting and wear, and R22 refrigerant charge low. Connected manifold gauges to verify system pressures and refrigerant levels. Given the age of the unit and multiple component failures, provided estimates for condenser fan motor replacement to customer for consideration.
Responded to no cooling complaint on 2-year-old mini split system. Found indoor and outdoor units running but system not providing cooling to space. Upon inspection, discovered complete refrigerant loss due to leak at outdoor unit flared connection fitting. Brass service valve and flare fitting showed improper installation with visible signs of refrigerant leak at connection point. System was operational but unable to cool due to zero refrigerant charge. Created installation correction documentation for repair team to return, properly remake flared connection, pressure test system, and recharge to factory specifications. Customer notified that office will schedule follow-up appointment for corrective work.
Responded to a water leak in the main water line from the well pump system. Upon arrival, confirmed the previously identified leak location and discovered a broken pressure tank tee as the source of the failure. Removed the damaged tee fitting and installed a new replacement tee to restore proper connection integrity. Tested the system for leaks and verified proper water pressure restoration. The repair addressed the immediate failure point and restored water service to the property.
Responded to kitchen sink water leak caused by deteriorated faucet fixture. Inspected old farm-style ceramic sink with wall-mounted faucet showing significant corrosion, tarnishing, and finish deterioration. Documented existing conditions with photographs showing extensive oxidation and worn metal surfaces on single-handle fixture. Assessed mounting configuration and determined replacement necessary due to age and condition of existing hardware. Prepared parts order form to provide pricing options for new faucet with portable dishwasher hookup capability compatible with vintage sink mounting requirements.
Completed comprehensive tune-up and maintenance on two 17-year-old geothermal heat pump systems as part of scheduled agreement service. Thoroughly tested all system components, verified loop field operation, and confirmed proper functionality of both units. Performance testing showed excellent temperature differentials with the basement unit achieving 17°F and the garage unit achieving 18°F, indicating both systems are operating within optimal parameters.
Performed comprehensive AC tune-up on residential cooling system. Outdoor condenser coil was found completely plugged with debris and was thoroughly cleaned and rinsed to restore proper airflow. Electrical components inspected with no issues identified. Furnace filter was severely clogged and had been pulled into the blower assembly; replaced filter with homeowner-supplied unit. Upon system startup, temperature split was inadequate, prompting refrigerant charge verification. Gauges confirmed system was low on refrigerant. Communicated findings to occupant present at property for relay to homeowners, explaining the low refrigerant condition and need for recharge. Added refrigerant to system to restore proper cooling capacity.
Performed comprehensive AC tune-up on 5-year-old residential air conditioning system. Cleaned outdoor condenser coil and inspected electrical connections at condensing unit. Performed drain line blow-through and replaced filter. System operating properly with no deficiencies identified at time of service.
Responded to no cooling complaint on 8-year-old residential AC system. Upon diagnosis, found unit low on refrigerant charge. Contacted homeowner to discuss repair options and potential future concerns regarding the refrigerant loss. Homeowner authorized immediate repair to restore cooling. Added 2 pounds of R-410A refrigerant and injected UV dye into system to aid in future leak detection. Verified system operation with 15° temperature split across evaporator coil, confirming adequate cooling performance. System returned to normal operation.
Responded to reported gas odor at residence following recent utility meter replacement. Upon arrival, confirmed gas leak at downflow furnace that had been previously flagged by utility company near combustion chamber and main gas valve. Inspection revealed exhaust vent was detached and gas valve was leaking past internal components. Determined valve failure was allowing gas to escape into living space, creating hazardous condition. Installed new gas valve assembly to eliminate leak and restore safe operation. Verified proper combustion chamber integrity and reattached exhaust venting to manufacturer specifications. Performed leak test on all gas connections and confirmed system operating safely with no further gas detection.
Completed comprehensive AC tune-up on Bryant condensing unit in response to complaint of system running continuously. Performed full system diagnostics and found unit operating with low refrigerant charge, measuring 7°F subcooling against target of 10°F and 13°F delta T across evaporator coil. Provided quote for adding one pound of R-410A refrigerant to restore proper system charge; homeowner elected to defer refrigerant service at this time. Scheduled follow-up appointment to provide estimate for additional ductwork installation to kitchen area. Documented system conditions with photos of outdoor condensing unit and basement mechanical equipment.
Responded to no-cool complaint on 4-year-old residential air conditioning system. Upon arrival, found outdoor condenser unit heavily obstructed by overgrown vegetation and debris accumulation, preventing proper airflow and heat rejection. Condenser coil was completely blocked, causing system shutdown and loss of cooling capacity. Cleared vegetation from around unit perimeter to restore proper clearance. Performed thorough condenser coil cleaning using pressure washing to remove packed debris and restore heat transfer efficiency. Replaced dirty air filter with homeowner-supplied filter. Restarted system and conducted operational testing. Verified proper cooling function with 22°F temperature split across evaporator coil, confirming system returned to normal operation. Recommended maintaining adequate clearance around outdoor unit to prevent future airflow restrictions.
Performed comprehensive AC tune-up on existing system, including cleaning of routine components, filter inspection, and testing of all equipment. Removed dead mouse from unit, cleaned and secured electrical wiring connections, and verified proper system operation. Documented equipment make, model, and serial numbers with photographs for maintenance records.
Responded to multiple plumbing issues throughout the residence. Replaced faulty Moen cartridge in upstairs shower valve to restore water flow and repair inoperable shower knob. Addressed leaking well line by repairing 1-inch copper pipe connection showing visible corrosion and oxidation. Inspected basement faucet with visible drip during irrigation system operation and verified water supply connections. Evaluated bathroom sink with crack and assessed faucet requiring replacement for future service. Inspected corroded shut-off valves and pipe fittings showing significant deterioration with rust and green patina buildup. All repairs completed without requiring main water shutoff to the property. Documented conditions of plumbing components including aged metallic valves, flexible connectors, and corroded pipe joints for maintenance records.