Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Performed tune-up maintenance on heating system including replacement of air and oil filters. Verified equipment operation was satisfactory but did not have correct nozzle size (.50/70°B) on hand. Will schedule return visit to complete nozzle replacement.
Diagnosed and resolved furnace "no heat" complaint caused by deceased rodent in exhaust elbow creating pressure switch fault. Removed obstruction, cleaned drain lines and trap to ensure proper operation. System is now operating normally with adequate heat output. Customer advised to monitor LP tank level (currently at 20%) as this could affect heating performance.
Responded to no-heat complaint on 3-year-old natural gas furnace reporting error code 57. Diagnostic testing revealed faulty pressure switch failing to consistently transfer 24V signal despite mechanical operation. Installed temporary pressure switch to restore heat while permanent replacement part is sourced.
Completed preventative maintenance on 18-year-old LP furnace. Inspected heat exchanger which appears in good condition. Noted inducer motor drawing slightly higher amperage than rated specifications. System safety checks performed with all operations confirmed normal. Observed LP tank is full and identified existing natural gas connection for potential future fuel conversion option.
Responded to no heat complaint on older mobile home furnace. Diagnosed water accumulation in inducer motor due to plugged condensate line. Drained approximately 2 cups of water from collector box and cleaned trap to restore proper drainage. Noted significant bearing play and dirt accumulation in blower motor. After clearing condensate and cycling power, furnace operated normally for 20 minute test period. Heat exchanger inspection revealed no compromises. Customer advised to schedule evaluation for potential replacement options due to unit's age and condition.
Responded to no heat call for church basement furnace. Diagnosed multiple issues including a dislodged capacitor (4uf), failed blower capacitor (15uf reading 0uf), detached blower wheel, and overheating motor. Discovered thermostat for corresponding upstairs zone was incorrectly set to cool mode. Restored temporary heat by setting thermostat to heat mode and cycling power, but recommended permanent repairs including blower motor and wheel replacement due to component condition. Disabled basement furnace power and provided customer instruction on situation.
Diagnosed no heat complaint on 20+ year old forced air furnace where system would turn on but blower wasn't functioning. Found blower motor capacitor severely failed (measured 0.255 µF against 5 µF specification). Replaced capacitor which restored proper system operation. Noted potential heat exchanger issue requiring further evaluation; scheduled follow-up with service advisor due to age of equipment.
Responded to customer complaint of intermittent heating failure on 5-year-old Lennox furnace. Upon arrival, system was operational but customer reported previous ignition failures. Performed diagnostic testing with multiple power cycles, revealing consistent operation each time. Completed preventative maintenance including cleaning a dirty flame sensor, inspecting heat exchanger integrity, and verifying proper gas pressure. System maintained stable operation with appropriate 45°F temperature rise during extended 15-minute test run.
Responded to no heat call for a 23-year-old furnace. Diagnosed system throwing error codes due to faulty hot surface igniter, which was not glowing despite power reaching it (confirmed at 0 ohms). Observed proper operation of inducer motor and pressure switch. Also identified significant corrosion on the manifold for the in-floor radiant heat system, with visible blue-green oxidation on multiple copper fittings. After discussing options, homeowner declined repairs as system was previously identified as nearing end of life during October service visit.
Diagnosed recently installed Bradford White water heater reporting no hot water. Found insufficient voltage supply (99V) to unit despite presence of intact fuse at peak time box. Multiple reset attempts unsuccessful. Electrical issue identified beyond plumbing scope - customer advised to contact electrician for proper voltage restoration to water heater circuit.
Diagnosed furnace showing no heat condition on a unit less than 10 years old. Inspection revealed a failed control board causing system malfunction. Installed universal control board to restore heating functionality, with recommendation for system replacement evaluation.
Responded to no heat service call for vacant property with a Comfort Maker forced air furnace. Diagnosed inducer motor running continuously due to stuck open pressure switch. After clearing the switch, performed heat exchanger inspection which revealed significant cracking in primary cell. Equipment was tagged out of service due to safety hazard. Communicated findings to property contact and discussed options for heat exchanger replacement versus full system replacement.
Responded to customer's no-heat complaint following water treatment installation. Diagnosed furnace reaching high limit switch during extended cold weather runtimes, causing system lockout. Performed system inspection while monitoring operation, measured supply temperature (132°F), and increased blower speed to improve heat transfer and prevent future limit trips.
Performed annual tune-up on 20-year-old furnace. Equipment was inspected thoroughly and found to be well-maintained with no operational issues detected. System is currently functioning properly and no repairs were required.
Performed annual tune-up on one-year-old Lennox furnace installed in basement. Verified gas pressure and all components operating within specifications. Checked temperature rise and confirmed proper blower settings for basement return air configuration. System operating normally with no issues identified.
Replaced faulty variable speed combustion inducer assembly on HTP boiler. After installation, adjusted combustion settings and verified proper boiler operation.
Performed scheduled maintenance on Bryant furnace which is currently operational but showing signs of deterioration. Inspection revealed a melting sight glass behind burners indicating potential secondary heat exchanger restriction, significant buildup in the condensate trap, and failing blower motor bearings with delayed RPM engagement. Communicated findings to homeowner and scheduled follow-up for replacement options, as system is approaching end of useful service life.
Diagnosed no heat complaint on upper level of commercial property. Investigation revealed excessive heat in mechanical room (80°+) affecting thermostat reading in nearby main living area, preventing boiler activation for outer rooms. Confirmed system functionality by manually setting thermostat to 90° which successfully activated boiler and heated registers. Recommended installation of ventilation/exhaust fan in mechanical room to prevent heat transfer to living space and scheduled follow-up with Russ to implement solution.
Installed a 50-gallon natural gas power vent water heater, replacing existing unit of similar type. Additionally, secured loose dishwasher with screws to prevent movement and restored hot water pressure to main level bathroom sink by fully opening a partially closed valve located in the ceiling.
Performed promotional furnace tune-up on customer's two-year-old Lennox system with integrated Aprilaire air cleaner. Comprehensive inspection revealed system is operating according to specifications with no issues detected. All components functioning properly with no maintenance or repairs required at this time.