Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to water leak emergency in mechanical room where a 3-inch section of copper pipe between two PEX lines had failed at the connection point. Water supply to the duplex was shut off prior to arrival. Removed the failed copper section and replaced with continuous PEX tubing, eliminating the vulnerable transition point that was previously spraying water onto the furnace. Restored water service to both residential units after confirming proper installation and no leaks.
Installed homeowner-supplied kitchen faucet with side sprayer in double-basin stainless steel sink. Assessed basement toilet installation but determined customer's Tuscany model was incompatible with existing high flange; substituted with Gerber toilet for proper fit and function. Boxed customer's original toilet and placed in their vehicle.
Diagnosed and resolved no heat issue in basement zone with fan coil and mercury thermostat. Upon inspection, discovered disconnected wire from end switch to relay to thermostat. Reconnected wire, restored system functionality with independent control for both upstairs and downstairs thermostats. Equipment inspected included CF5282868 unit and ceiling-mounted blower assembly in basement utility area.
Conducted semi-annual maintenance on 20+ year old furnace. Diagnostic testing showed unit operating at 87% efficiency (below rated 92%) with elevated stack temperature of 157°. Heat exchanger appears intact, but secondary exchanger likely becoming plugged. Discussed replacement options with homeowner who will consider options after the holidays.
Performed comprehensive furnace tune-up on 5-year-old unit. Replaced dirty filter with customer-supplied replacement and verified all electrical components were within specifications. Inspected heat exchanger (no issues found), confirmed proper condensate drainage, and tested system operation with verified gas pressures showing 45° temperature rise. Unit functioning optimally after 15-minute test run.
Performed scheduled annual maintenance on residential generator. Completed full service including replacement of spark plugs, air filter, and oil filter along with complete oil change. Reset maintenance notification, verified proper system settings and confirmed battery condition. Generator is fully operational and maintenance requirements have been satisfied for the current service cycle.
Located and repaired a burst pipe in a challenging crawl space with significant ice buildup due to non-functioning heat in that area. Replaced approximately 5 feet of damaged line with PEX and installed new valves in the laundry room, resolving the leak despite difficult access through a very small crawl space opening.
Replaced leaking expansion tank and air vent on customer's boiler system. Installed new components and verified proper operation with no leaks during startup. System now functioning correctly with normal water flow.
Performed scheduled tune-up maintenance on Weil-McLain boiler at client's airplane hangar facility. Disassembled and thoroughly cleaned heat exchanger, flame sensor, and condensate system. Verified proper boiler operation and functionality after service completion.
Responded to call for Lennox NG furnace (6 years old) that was shutting down intermittently. Customer reported unit would run for extended periods then cease operation, with operation restored after blower door removal. Diagnosed and removed shipping bolt still attached to blower housing, which was causing operational issues. Applied dielectric grease to motor module connections to prevent future connectivity problems. Tested unit through multiple on/off cycles to confirm proper operation. Unit now functioning normally.
Performed annual furnace tune-up on 2-year-old FRP system. Inspected filter, blower, electrical components, condensate lines, and heat exchanger - all in good condition. Tested system operation for 15 minutes, confirmed proper gas pressures with 65° temperature rise. Addressed customer's report of occasional rumbling noise during shutdown, though no abnormal sounds were observed during testing. System functioning properly per manufacturer specifications.
Responded to emergency service call for a leaking water heater system in utility room. Upon inspection, identified active leak from bottom of the tank with approximately 1/2 inch of standing water collected in drain pan. Documented existing configuration including expansion tank and associated copper piping connections. Recommended complete replacement of the failing unit.
Responded to no-heat call for a 3-5 12-4 NG furnace displaying "LPS Pressure switch" error. Diagnosed exhaust vent blockage in attic causing system failure. Cleared blocked exhaust vent piping, which allowed proper venting and restored normal furnace operation.
Diagnosed and resolved heating complaint by identifying thermostat was reading 3°F lower than actual room temperature due to cold air infiltration through wall penetration behind unit. Installed foam insulation behind thermostat to seal air leak, resulting in accurate temperature readings. Increased boiler maximum water temperature from 174°F to 182°F to improve heating capacity during extreme cold conditions.
Diagnosed issue with previously installed humidifier that was not operating properly. Verified wire hookup and tested system in test mode, but could not activate the unit. Documentation of thermostat settings was completed. Issue requires follow-up service visit with Lennox Technical Support to resolve humidifier functionality problems.
Completed annual furnace maintenance on 1-year-old FRP system. Performed comprehensive tune-up including inspection of heat exchanger (no compromises found), cleared condensate lines, verified electrical components were within specifications, and cleaned/balanced blower. System demonstrated proper operation with gas pressures within range and temperature rise of 70°F. Recommended replacement of filter due to accumulation of dirt.
Successfully installed customer-supplied kitchen faucet in rental property after previous fixture blew off the sink. Existing water supply stops were in good working condition and were reused. Completed installation with proper under-sink connections to drainage system, though noted the provided faucet model is not ideal for rental property applications.
Diagnosed issue with Weil-McLain boiler experiencing irregular cycling and flame sensing problems. Inspection revealed boiler would cycle approximately 20 times before establishing proper ignition. After cleaning flame sensor with minimal improvement and confirming 0 microamp reading, recommended pilot assembly replacement. Customer authorized replacement part order and estimate was signed for new pilot assembly.
Responded to service call for Ruud furnace (2 years old) reporting intermittent heating issues with blower not turning on and reduced system efficiency. Diagnostic testing revealed fault code A061_F indicating "Blower Fault - Motor Cannot Run." Performed comprehensive system check including static pressure and temperature differential measurements; located and secured loose top molex plug connection to ECM motor module which resolved the operational issue. System functioned normally with no error codes during remainder of service visit.
Diagnosed no-heat complaint on nine-month-old Lennox furnace that was intermittently blowing cold air and shutting off. Inspection revealed incorrect exhaust/intake terminations from initial installation with significant frost buildup. Properly reconfigured terminations to manufacturer specifications and reset error codes. System now operating correctly.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.