Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to service call regarding previously ordered parts. Installed heat relay to enable proper humidifier operation as system was not producing humidity. Installation was completed successfully and wiring connected to control board per manufacturer specifications.
Responded to a reported low water pressure issue at restaurant. Diagnosed problem as leaking urinal affecting building pressure. Isolated urinal water supply while restoring main water service to kitchen. Tested urinal functionality after restoration, confirming both push button and motion sensor operation functioned properly. Restored normal water pressure to establishment.
Responded to no-heat call for 11-year-old LP furnace. Diagnosed system in one-hour lockout condition caused by cracked hot surface igniter. Noted heat exchanger appears suspect and furnace shows significant wear. Replaced HSI, tested system operation, and restored heat.
Responded to service call regarding no hot water in downstairs shower while other fixtures maintained hot water supply. Diagnosed issue as faulty shower valve. Removed and replaced Moen cartridge, restoring proper hot water flow to shower.
Performed comprehensive furnace inspection on 15-year-old unit running at reduced efficiency (88.4% vs rated 92%). Identified heat exchanger showing stress with possible pinhole deterioration and inducer motor bearings exhibiting wear. Inspected Aprilaire humidifier system and documented condition. Discussed aging equipment concerns with homeowner for future consideration.
Successfully relocated utility laundry sink approximately 3 feet to accommodate customer's refrigerator and countertop installation. Reconfigured exposed PEX water lines, PVC drain, and vent piping to new location with proper connections. Verified functionality after installation with no leaks.
Performed routine maintenance on 5-year-old furnace system. Replaced customer-supplied dirty air filter, cleared condensate lines, inspected electrical components and heat exchanger with all found within specifications. System tested with proper operation confirmed by 45° temperature rise during 20-minute runtime test. Verified proper venting and gas pressures. Recommended spring maintenance for AC unit.
Diagnosed intermittent furnace operation caused by flame sensor issues and high limit code trips. Cleaned flame sensor, verified condensate drainage, and checked pressure switches/hoses. Identified primary causes as restricted airflow from plugged evaporator coil and blocked return vent. Cleaned evaporator coil and installed new return in the blocked-off hole to restore proper system operation.
Responded to no heat call for aging system (10+ years). Diagnosed failed inducer motor that was initially locked up but temporarily freed. After inspection of motor assembly and blower components, provided customer with replacement options. Customer elected to defer inducer motor replacement at this time despite recommendation for complete system upgrade due to unit age and condition.
Replaced failed sewage ejector pump in basement as per estimate. Additionally installed new ADA-compliant rounded toilet and replaced angle toilet as requested by customer. Total service took approximately 4-5 hours, resolving basement drainage issues and upgrading bathroom fixtures to meet accessibility requirements.
Performed scheduled furnace tune-up on Lennox system, finding all routine electrical components and heat exchanger within specification. Identified water leaking from secondary drain due to incorrect furnace pitch. Completed maintenance including filter inspection, humidifier pad check, flame sensor cleaning, and gas pressure verification. Both main furnace and garage unit were tested with proper operation confirmed at 70 degree temperature rise. Customer informed that office will schedule return visit to correct furnace pitch issue.
Responded to water leak from refrigerator line caused by malfunctioning saddle valve. Per customer's request, eliminated the valve completely as they no longer wanted water supplied to the refrigerator, thus preventing future leaks from the same source.
Responded to no heat complaint on 10+ year old furnace system (1996 model). Diagnostic inspection revealed non-functioning blower despite ignition occurring. Found burned out ignitor and identified significant crack in primary heat exchanger at the burner inlet underside. Due to safety concerns, tagged furnace as hazardous and recommended system replacement. Scheduled follow-up with service advisor for replacement options.
Performed diagnostic assessment on three cascaded IBC boilers following report of one unit overheating (190-200°F) and entering high limit shutdown. Inspected all boilers and verified proper operation after customer had previously shut gas off to problematic unit. Tested circulation pump functionality with amp draw measurement (0.73 amps) confirming proper operation. No current issues detected; recommended monitoring performance and potential replacement of 007 pump or inspection of check valve if problem recurs.
Replaced faulty gas valve under warranty on HVAC system. After installation, unit operated properly for approximately 20 minutes before exhibiting intermittent function issues. Determined replacement valve may also be defective; new gas valve has been ordered to resolve the ongoing heating issue.
Responded to emergency service call for basement flooding in furnace room. Diagnosed failed grinder pump as source of water leakage affecting toilet and shower areas. Installed replacement grinder pump, new toilet, and new toilet shut-off valve to resolve flooding issue. System tested and confirmed operational with proper drainage restored.
Diagnosed restricted cold water supply to shower valve preventing temperature adjustment. Completed initial assessment of marble-tiled shower stall with brushed bronze fixtures. Initiated parts order for necessary components to restore proper water temperature control.
Responded to emergency water leak in basement mechanical room originating from kitchen sink. Discovered kitchen faucet head was coming apart causing significant leakage. Cleaned clogged drain in master bathroom sink and identified leaking tank T in basement water treatment system. Advised customer that tank T repair would require follow-up appointment.
Replaced non-functional kitchen faucet with new American Standard single-handle model featuring modern design and functional sprayer. Also inspected toilet for potential issues as requested by customer. Both fixtures now operating properly with no leaks.
Performed annual maintenance tune-up on 2-year-old furnace per service agreement. Replaced dirty filter, cleaned and balanced blower, and verified all electrical connections. Inspected heat exchanger (no compromises found) and ensured condensate lines were clear and draining properly. System tested with satisfactory 70-degree temperature rise after 20-minute operational test, with proper venting confirmed.