Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to service call regarding thermostat communication issues. Diagnosed thermostat not communicating with smart hub. Performed system reset which successfully restored connectivity between components. Educated homeowners on reset procedure for future occurrences.
Responded to no heat call at 7-year-old residence. Diagnosed issue was thermostatic control error - resident had inadvertently set system to cooling mode while dusting. Restored proper operation by switching thermostat to heating mode, verified system startup and proper function. Equipment inspection confirmed R-410A system in satisfactory condition.
Responded to service call for 2011 40-gallon natural gas water heater that was failing to maintain ignition. Unit would initiate heating cycle and ignite but wouldn't stay lit after three attempts. Diagnosed issue as dirty flame sensor. Performed cleaning of flame sensor which restored proper operation and continuous flame detection during heating cycles.
Performed standard furnace maintenance on two units (4 and 11 years old). First unit was operating properly with clean filter, good electrical components, and normal temperatures. Second unit required air filter replacement as it had been pulled into blower compartment. Discovered broken condensate line behind Geo unit in garage that requires repair; homeowner may attempt self-repair or request professional installation of new line from furnace to bathroom. Removed debris from fresh air intake on concentric vent and completed routine inspection of heat exchanger.
Inspected homeowner's sump pump system that had been previously repaired with hose clamps and electrical tape. Identified leaking check valve in sewer ejector system. Reviewed proper installation requirements with customer who elected to perform the replacement themselves.
Diagnosed 2007 natural gas furnace with complete system failure after customer reported burning smell. Investigation revealed seized blower motor, which explains both the burning odor and system shutdown. Ordered replacement blower motor specific to the Nordang unit. Verified thermostat was operational but unable to engage heating cycle due to failed motor component.
Performed routine furnace inspection for new customer Jesse. Found multiple issues including an out-of-spec blower capacitor, noisy inducer motor, and cracked AC coil pan. During inspection, the HSI (hot surface ignitor) failed and cracked upon reinsertion - replaced with new unit from service vehicle. Completed full system assessment and scheduled follow-up service.
Responded to service call regarding previously installed Bradford White water heater temperature adjustment. Customer reported insufficient hot water. Inspected unit and confirmed water temperature was approximately 110°F. Adjusted thermostat setting to increase water temperature to 120°F, resolving the issue. Unit is now operating at proper temperature.
Responded to a customer complaint of intermittent hot water loss during showers with their Navien tankless water heater. Upon inspection, found that the existing unit showed signs of age-related deterioration and active leaking. Conducted a thorough evaluation of the system and provided customer with replacement options for both the tankless water heater and the addition of a water softener to prevent future scaling issues and extend equipment lifespan.
Inspected bathroom sink with reported cold water leak. Found dripping supply line connection at shut-off valve. Advised customer regarding options to replace stop valve and supply line immediately or replace entire vanity due to water damage and cabinet deterioration. Customer elected to procure new vanity and faucet themselves, with installation to be scheduled at a later date.
Performed comprehensive furnace tune-up on 2-year-old FRP unit. Replaced customer-supplied dirty filter, inspected electrical components and heat exchanger (all within specifications), verified condensate drainage, and confirmed proper venting with 60-degree temperature rise during 20-minute maximum heat rate test. System functioning correctly; advised customer to replace filter monthly.
Responded to service call regarding water heater leakage and burning odor. Assessed existing unit which showed signs of significant failure. Replaced damaged water heater with new equipment, completing all necessary plumbing connections including proper PVC ventilation and copper supply lines with appropriate valving. Installation verified with no leaks upon completion.
Diagnosed and resolved ignition issues on recently installed Lennox cast iron boiler. Found plastic debris obstructing pilot orifice which was preventing proper gas flow to pilot. Cleaned orifice thoroughly, verified successful ignition, and conducted multiple test cycles at various temperature points to ensure reliable operation. Installed compatible universal control board after original parts were determined to be incorrect for this model.
Performed annual maintenance on 1-year-old Lennox residential furnace system per agreement. All components inspected and tested within manufacturer specifications. Demonstrated proper filter replacement procedure to homeowner, with recommendation to replace in approximately two months. System operating normally at service conclusion.
Responded to service call for kitchen sink clog. Located blockage approximately 10 feet down the drain line and successfully cleared using appropriate drain cleaning equipment. Performed flow test after clearing to confirm proper drainage was restored and sink is now functioning properly.
Responded to a service call for a 10+ year old furnace cycling frequently and not running properly. Upon inspection with homeowners, discovered the system is now heating an additional 1500 square feet not accounted for in original installation, causing short-cycling issues. Customer had already ordered replacement inducer motor; assisted with evaluation and discussed both current repair options and potential system replacement due to inadequate sizing for the expanded space.
Performed warranty replacement of overheating blower assembly. Removed existing blower motor, installed new Genteq PROTECH replacement motor, and verified proper system operation in both fan and heat modes. Unit now functioning correctly.
Inspected water system in response to no water pressure throughout house. Diagnosed failed well pump as root cause of issue. Recommended customer contact a well drilling specialist for pump replacement and provided referral to well company.
Completed 8-12 Furnace tune up on 22-year-old FRP unit. Identified multiple critical issues including leaking secondary heat exchanger, inducer motor shaft movement, and broken drain hose reducer. Unit was tagged out of service, gas line and breaker shut off, and space heaters provided to customer. Scheduled for service advisor follow-up due to safety concerns.
Responded to customer concern of newly installed Lennox WT boiler exhibiting loud banging noises during ignition sequence. Diagnostic testing revealed gas pressure at half the required specification, causing delayed ignition and combustion issues. Informed homeowner to contact gas company for pressure adjustment to resolve primary issue. Preventatively ordered replacement gas valve and pilot control board components as contingency if pressure correction proves insufficient.