Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no-heat call for 4-year-old system. Diagnosed exhaust pipe blockage on roof that had frozen over, requiring removal of T-fitting to clear obstruction. Upon roof inspection, discovered excessive pipe movement which led to attic investigation where a disconnected exhaust elbow was found venting combustion gases into attic space. Repaired and secured the disconnected elbow joint with appropriate adhesive to restore safe operation. Noted lack of insulation on all attic exhaust piping, which likely contributed to condensation freezing. Recommended insulation installation for all exhaust runs to prevent future blockages.
Located and repaired a ruptured half-inch water line in customer's plumbing system. Identified copper pipe fittings with significant oxidation and corrosion damage, likely caused by freezing conditions. Completed repair work that had been previously started, replacing damaged sections with new PVC piping after receiving customer's insurance approval.
Performed annual maintenance on a 1-year-old Lennox furnace. Inspected and tested all components, confirming proper operation throughout the system. No issues or concerns identified during the service visit.
Diagnosed and serviced malfunctioning sump pump system in basement mechanical room. Identified that the float was obstructed by debris causing pump failure after GFI reset. Thoroughly cleaned out sump pit, properly repositioned the float mechanism, and restored normal pump operation. Additionally, pulled and reset a leaking basement toilet that had been affected by the backup.
Replaced draft combustion inducer assembly on furnace #3 and collector box/cold end header box on furnaces #1 and #2 as specified in the approved repair estimate. All components were properly installed according to manufacturer specifications, restoring proper functionality to the Goodman heating units. Work was completed in the utility room where the three furnace units are located adjacent to the main electrical panel.
Performed annual maintenance on Tempstar furnace of undetermined age. Inspected and tested all components with furnace operating properly for 20 minutes. System is heating correctly with no issues identified.
Responded to emergency water leak in basement caused by lawn faucet failure. Diagnostic inspection revealed the lawn faucet had completely separated from its connection point, with active water spraying from a damaged PVC pipe and metal connector. Removed damaged components, installed new lawn faucet assembly, and verified proper operation with no leaks. Water damage was contained primarily to the basement area with some moisture affecting floor joists and insulation.
Responded to a no-water service call during cold weather conditions; customer suspected frozen pipes. Upon inspection, confirmed all water systems were functioning properly with normal pressure throughout the residence. No frozen pipes were identified and no remedial action was required.
Responded to callback for no heat complaint after previous service. Diagnosed high temperature limit error code, reinstalled original limit switch and verified functionality. Identified inducer housing leak requiring replacement. Submitted parts request for new limit switch and inducer housing. System temporarily operational pending installation of ordered components.
Responded to no-heat emergency call. Diagnosed system shutdown due to blocked air filter. Replaced filter, performed factory reset on Google Nest thermostat and assisted customer with reinstallation. System operated normally for 30 minutes post-service. Recommended additional filters and insulation for large opening in basement near water supply causing cold air infiltration.
Repaired broken water supply line to toilet. Located leak in crawl space beneath bathroom floor. Cut minimal access hole in floor to reach damaged pipe, then replaced and reconnected the copper supply line with appropriate fittings. Verified proper function and absence of leaks after repair.
Responded to no-heat call for 10+ year old furnace that was previously serviced this month. Discovered thermostat fan was set to "ON" causing blower motor to cycle improperly (producing clicking sound). Switched fan setting to "AUTO" which resolved immediate issue. Identified secondary problem with furnace shutting off on temperature limit due to restricted airflow. Replaced clogged air filter and advised customer that maintaining "AUTO" fan setting would extend filter life and prevent similar issues.
Responded to no heat complaint on aging system. Diagnosed inducer motor failure evidenced by humming noise without rotation. Identified Fasco unit (P/N 70861023) completely locked up. Placed order for replacement inducer assembly to restore heating functionality.
Responded to no heat complaint at commercial building with 20+ year old furnace. Diagnosed faulty heating relay that was chattering badly. Performed reset which temporarily restored operation, but relay requires replacement. Current building temperature at 57°F. Submitted estimate for relay replacement to customer via email pending approval.
Responded to service call for tank water heater producing only warm water. Diagnosed pilot light was out. Performed inspection of pilot assembly and burner system. Successfully relit pilot light, restoring proper heating function. Noted 5-inch flue pipe connected to 3-inch water heater connection and possible wind interference from nearby Lake Wassota affecting pilot operation.
Responded to no hot water complaint on 3-year-old Richmond power vent water heater. Diagnosed issue as tripped breaker in electrical panel due to customer using multiple space heaters on same circuit. Reset breaker to restore power to water heater.
Responded to callback service for no heat issue after recent repair. Upon arrival, found blower running but heating system not firing. Diagnosed loose connection at hot surface ignitor (HSI), disconnected and reconnected the HSI plug which restored proper system operation. Verified repair by testing system startup multiple times with consistent ignition confirmed. System now heating properly with thermostat displaying correct operation.
Responded to service call for 16-year-old Kenmore water heater with no hot water output. Diagnostic testing revealed pressure switch code error. Performed troubleshooting on pressure switch and inspected tank components showing significant corrosion and deterioration. Provided customer with options for pressure switch replacement or complete water heater replacement. Customer will consider recommendations and respond with decision.
Responded to no heat call for 15-year-old furnace system. Inspection revealed 1986 70% efficiency furnace with severe heat exchanger deterioration, including large crack on right side burner face plate and multiple holes in exhaust. System deemed unsafe to operate; customer was informed of hazardous condition and declined repairs. Emergency service arranged for same day.
Diagnosed and resolved a no-heat issue on a 2-year-old Lennox furnace that had previously tripped out after repair. Upon thorough inspection of heat exchanger cells and burners, discovered incorrectly swapped exhaust terminations causing recirculation and rollout trip. Corrected the exhaust pipe configuration and verified proper operation with 40-minute run test. Removed temporary space heaters from the premises.