The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no-heat call for aging furnace likely original to 1970s home. Diagnostic testing revealed failed gas valve receiving power but not allowing gas flow. Further inspection identified multiple cracks in heat exchanger. Due to safety concerns, shut down system and advised homeowner that replacement of entire furnace is recommended rather than component repairs. Homeowner declined service advisor option and will pursue alternative assistance.
Responded to service call for 6-year-old natural gas furnace with intermittent heating issues and shutdown problems. Diagnosed clogged filter caused by cool mist humidifier in living room as the primary issue. Performed system inspection and filter replacement, restoring proper operation. Educated customer about proper humidifier usage and maintenance to prevent future issues.
Diagnosed 1999 Carrier Weather Maker furnace with failed heat exchanger. Visual inspection revealed leakage points and combustion testing confirmed significant blockage. Identified customer had been manually resetting rollout switch to maintain operation. Observed blackening of exhaust tubing and improper combustion odors in living space. Recommended complete replacement of heat exchanger or furnace unit due to safety concerns.
Replaced faulty heating relay on HVAC system, restoring proper thermostat control. System now successfully cycles on and off as designed. Parts sourced through ME distributor.
Responded to service call for furnace failure. Installed new hot surface ignitor and refilled condensate trap that customer had emptied, resolving exhaust gas backflow issue. Diagnosed intermittent pressure switch code despite switch functioning properly; determined control board replacement likely needed. Temporarily restored furnace operation and scheduled service advisor for follow-up evaluation of control board replacement.
Responded to service call for water leakage from supply lines in garage laundry tub. Replaced laundry supply lines to address the immediate leak issue. Recommended installation of interior shut-off valves with drain-down capability for freeze protection, but customer opted to defer this preventative measure.
Completed installation of kitchen faucet with upgraded water supply lines and new shut-off valves. Connected plumbing to sink and installed shut-off valves for icemaker and dishwasher. Dishwasher installation was not performed as part of this service.
Responded to sink drainage issue and determined clog was located in galvanized piping downstairs. Successfully cleared blockage by running snake machine through the drain twice, restoring proper drainage function.
Performed furnace tune-up on 11-year-old system after customer reported heating failure with temperature remaining 5 degrees below setpoint. Conducted full diagnostic inspection including electrical testing, flame sensor cleaning, and code recall check. Determined dirty air filter was likely cause of system failure; all components now testing within specifications and system operating normally.
Diagnosed no-heat condition on 10+ year old natural gas furnace with 4 blinking diagnostic lights indicating ignition failure. Cleaned flame sensor and vacuumed combustion chamber, but determined hot surface igniter (HSI) had failed. Replacement part ordered as existing igniter could not be properly fitted despite attempt.
Performed diagnostic on furnace that was not maintaining set temperature (72°F setting but only heating to 68°F). Found filter had been drawn into blower compartment and identified intermittent system shutdown due to flame sensor issues. After 10 minutes of operation, system shut down with solid red indicator light on ignition module, confirming control board failure. Advised customer of replacement options for both control board and complete furnace replacement.
Replaced non-functioning 50-gallon electric water heater from 2007 with new Bradford White 50-gallon electric unit. Customer was not available until 2:30 PM; coordinated arrival time with Pat prior to service.
Replaced leaking 50-gallon electric water heater with new unit of same capacity. Confirmed proper electrical connections at breaker panel prior to installation. Completed installation for tenant Marc after receiving authorization from property owner Linda.
Responded to service call for leaking washer hookup valves. Inspected the recessed utility box containing hot/cold water valves and found loose packing on the hot water valve causing the leak. Tightened the packing to resolve the issue and provided customer with estimate for future toilet replacement work.
Responded to a service call for a frozen and split copper water line that supplies the upstairs bathroom and laundry. Created an 8x8 access hole to reach the damaged pipe, which had previously been improperly repaired with a wrap. Successfully replaced the broken section of copper pipe, restoring water flow to the upper level. Customer was informed that drywall repair services are not included.
Responded to no heat complaint and installed new draft combustion inducer assembly. Upon testing, discovered failed gas valve and non-operational condensate pump. Inspected heat exchanger which showed areas of concern but no compromises. Communicated findings to landlord and recommended obtaining estimates for additional repairs given unit's age and condition, with follow-up appointment scheduled.
Responded to intermittent no heat complaint where system was displaying code 240 (no ignition). Upon arrival, furnace was operational. Performed diagnostic testing including high/low fire verification and gas pressure measurement, all within specifications. Cleaned flame sensor as preventative maintenance. System cycled multiple times without issue during service visit. Customer advised to monitor for any recurrence of intermittent operation.
Diagnosed non-functioning furnace with multiple critical failures: cracked heat exchanger with primary cell damage, cracked collector box causing water leakage throughout unit, and failed control board preventing inducer operation. Tagged unit due to compromised sealed chambers. Provided customer with temporary space heaters and arranged for advisor visit to discuss replacement options given the 10-year-old unit's condition.
Completed return trip to install OEM limit switch on furnace system. Upon arrival, discovered unit had tripped on rollout switch. Performed heat exchanger inspection with no issues found, but noted burners were lighting sluggishly. Cleaned burners with wire brush, installed new limit switch, and monitored system operation for 30-40 minutes to confirm proper function with no further issues.
Responded to service call for 15-year-old furnace with reported thermostat malfunction error. Customer had previously reset power to restore operation after furnace quit during cold weather. Inspection revealed no abnormal system operation, though ice buildup around exterior exhaust vent was noted as potential cause of previous malfunction. System operated properly throughout diagnostic testing. Furnace appears to be functioning normally following comprehensive inspection.