Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Conducted comprehensive plumbing inspection on 20-year-old residential unit with focus on water heater system and associated plumbing connections. Verified proper installation and functionality of water heater, circulation pump, copper supply lines, and PVC drainage components. All plumbing systems found to be in good working condition; noted recommendation for dishwasher replacement.
Performed comprehensive plumbing inspection of residential property, examining both exposed PVC and copper pipe installations. Inspected wall-mounted plumbing components, water meter/regulator valve, and connection points for proper sealing and secure mounting, with particular attention to the dehumidifier/HVAC system integration with the home's plumbing infrastructure.
Successfully completed tub/shower drain line replacement after identifying compromised drain pipes. Opened wall access to replace failing metal drain pipes with new PVC components, including proper P-trap installation. Restored full drainage functionality, preventing future system failures in the affected bathroom area.
Successfully completed installation of customer-supplied toilet with new shut-off valve and replaced a small Moen shower cartridge that was leaking when water was turned off. Service included proper fitting and connection of the toilet fixture and removal of the old Moen cartridge with installation of the replacement unit to resolve the water leak issue.
Responded to service call for newly installed furnace that was extremely loud with reports of persistent gas odor. Determined the noise issue was due to excessive blower speed and adjusted from medium to medium-low setting to reduce operational noise. Confirmed gas smell was not from a leak but from shipping oil burning off; ran furnace for 45 minutes while airing out the home to eliminate the odor completely.
Diagnosed no heat complaint on aging furnace system. Found restricted condensate tube due to items pressing against it; cleared obstruction by blowing out tube and removed items causing the restriction. Identified locked-up motor as primary failure point and observed potential heat exchanger damage. Recommended complete estimate for necessary repairs, with parts availability expected within 2-3 days.
Responded to service call regarding whistling noise from recently replaced shower head. Identified incompatible tub trim brand provided by customer. Inspected black shower fixture and trim components. Submitted parts order form for replacement black tub trim, drains, and overflow to properly match existing components and eliminate noise issue.
Conducted comprehensive inspection of residential water treatment system, including multiple filtration tanks (two blue cylindrical, one gray/beige, and one black brine tank) with digital control panels and associated PVC plumbing. Examined drainage components, including main white PVC drain pipe with elbow joint and connected metallic piping, documenting current condition with photos for reference.
Responded to service call regarding non-functional sump pump. Discovered water accumulation on basement floor due to malfunctioning float in sewage ejector pump. Successfully replaced the float mechanism, restoring proper operation of the sewage ejector system.
Successfully installed a high water alarm system on the existing sewer ejector to alert homeowner of potential water backups or flooding in the septic system. The two-hour installation included mounting the sewer alert mechanism to the pump basin, ensuring proper connection to the existing drainage infrastructure. All components were verified operational before completion, providing an effective early warning system for basement water issues.
Responded to no heat call for Gibson furnace. Diagnosed tripped limit circuit due to completely clogged air filter. Replaced filter and verified proper system startup and operation. System now functioning normally with restored heat output.
Replaced malfunctioning thermostat that was causing furnace to run continuously, resulting in indoor temperatures exceeding 100°F despite 60°F setpoint. Installed new T4 thermostat, configured to customer's preferred 62°F setting, and initiated cooling measures including activating fan mode and ceiling fans to reduce excessive heat.
Responded to a backflow inspection follow-up at commercial property where previous inspection identified compliance issues with upstairs toilets. Adjusted fill valve height on Kohler 1.6 gpf toilet fixtures to maintain required 1-inch clearance above overflow tube as mandated by code. Documented completed adjustments with photographic evidence of the modified installation.
Diagnosed heating issue on commercial 8-12 RTU installed in November by Hovland's. Discovered bath fans/occupancy sensors were improperly wired to economizer through thermostat, causing economizer to open fully during daytime operation and preventing proper heating. Disconnected occupancy wire from RTU control board, allowing economizer to maintain 10% fresh air intake without fully opening. This modification should resolve the continuous heating operation and inability to maintain temperature above 60-65°F.
Consulted with client regarding water heater replacement options. Provided information about advantages of tankless units compared to traditional tank models. Client expressed interest in purchasing a new water heater. Left instructions to contact Luke prior to next visit.
Installed customer-supplied thermostat and corrected existing furnace operational issues. Removed improper W1-to-W2 jumper and adjusted dip-switch settings to enable proper staging sequence (10 minutes in first stage before engaging second stage). Noted and informed customer about aging inducer motor showing signs of noise and leakage. Scheduled follow-up consultation for inducer replacement estimate and potential system replacement options.
Conducted plumbing inspection at rental property, identifying significant corrosion on tank tea and kitchen sink shut-off valve (010 type). Documented bathroom fixtures and existing Culligan water treatment system. Recommended replacement of corroded components and recline of tankless water heater, with service appointment scheduled for formal pricing.
Responded to service call regarding furnace filter issues. Upon inspection, discovered a reusable air filter had disintegrated and become lodged inside the furnace. Removed lower cover to extract all filter debris, then verified proper furnace operation. Recommended customer switch to disposable filters for easier maintenance and advised on regular filter inspection/replacement schedule.
Responded to a reported bathroom sink leak. Diagnosed leaking faucet requiring replacement. Documented condition of the plumbing system and water heater (A.O. Smith ProLine) during inspection. Provided customer with replacement options and awaiting approval before proceeding with repairs.
Accessed shower plumbing through cut access hole in tile to address pipe failure. Found corroded copper fitting with broken shower head and threads stuck inside eared ell. Replaced damaged 90-degree elbow fitting to restore proper shower functionality.