Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to service call for toilet backup and water leakage at base. Upon inspection, determined toilet was experiencing backup when shower was running, causing water to overflow from toilet base onto bathroom floor. Diagnosed issue as main drain line blockage beneath floor rather than toilet-specific problem. Recommended professional drain cleaning service to clear main sewer line obstruction. Advised customer that toilet would need to be removed and reset after drain line is cleared, and offered to return for toilet reinstallation if needed.
Returned to property to reposition stackable washer/dryer unit that was previously installed too close to door, preventing proper door clearance. Carefully moved heavy appliance approximately one inch away from door to allow full door operation while taking precautions to avoid further damage to vinyl flooring that had been previously compromised during initial installation. Documented final positioning with photos and confirmed satisfactory resolution with property owner.
Responded to warranty call for water leaking from furnace humidifier. Identified failed inlet line fitting as source of leak. Replaced defective push-to-connect fitting and installed new humidifier pad. System tested and verified operating properly with no further leakage detected.
Responded to kitchen sink clog and leak beneath cabinet. Upon inspection, discovered severely corroded galvanized drain pipe with hole causing water damage to cabinet interior and wall. Removed deteriorated galvanized section and re-piped kitchen drain assembly using PVC materials to ensure proper drainage and eliminate leakage. Additionally, replaced malfunctioning bathroom tub spout that was missing the diverter component, restoring proper tub and shower operation. All plumbing connections tested and verified leak-free upon completion.
Performed backflow prevention test on ASSE 1013 RPZ assembly (1 inch) and completed cross-connection control inspection. Testing procedures verified device functionality and all required documentation was completed, though it was noted the device is not currently registered with the proper authorities.
# HVAC Service Report - No Heat Call ## Summary Responded to no-heat call following power outage. Diagnosed and replaced faulty control board under warranty. Identified combustion blower failure causing error codes and preventing proper furnace operation. Replaced control board and verified system returned to normal heating operation. ## Service Details Customer reported heating system not functioning properly after power outage occurred several weeks prior. Thermostat had been reprogrammed following power loss, but furnace was not cycling on as expected. Upon arrival, performed diagnostic evaluation of heating system. Initial inspection revealed control board malfunction causing operational failure. Installed new warranty replacement control board and attempted to verify system operation. During post-installation testing, furnace continued to display error codes and failed to operate correctly. Further diagnosis determined combustion blower motor was not shutting off during norma
# Shower Valve Replacement Service Responded to service call for continuous water flow from shower caused by failed cartridge replacement attempt. Upon arrival, customer reported unsuccessful DIY repair of leaking shower cartridge. Inspection revealed the shower valve assembly was defective and beyond simple cartridge replacement. Performed complete shower valve replacement using customer-supplied American Standard shower valve unit. Removed existing failed valve assembly and installed new valve according to manufacturer specifications. Ensured proper water supply connections and verified all seals were correctly positioned. Tested system operation to confirm leak was eliminated and water flow control functioned properly. Documented completed installation with photographs for service records. System restored to full operational status with no active leaks detected.
# Service Report: Water Heater Replacement Responded to service call for leaking propane water heater. Upon arrival, confirmed active leak originating from bottom of existing unit, indicating tank failure. Diagnostic fee waived as replacement was clearly required. Removed failed water heater and installed new 50-gallon power vent LP (propane) unit. Connected gas supply line with shutoff valve, installed proper venting system with PVC exhaust piping, and completed all water supply connections using copper piping. Verified proper electrical connections for power vent motor operation. Tested all connections for leaks and confirmed unit fired properly with adequate combustion and venting. Per customer request, also removed old water softener system from premises. All removed equipment hauled away from property. Installation completed within scheduled service window. System operational and customer satisfied with completed work.
# Plumbing Service Report - Shower/Tub Drain Repair ## Work Performed Responded to service call for upstairs bathroom with multiple drainage issues affecting both the lavatory sink and bathtub/shower unit. Upon inspection, identified failed gaskets on sink drain assembly and complete drainage failure in bathtub due to obsolete drum trap configuration. The primary challenge involved the bathtub drain system, which was equipped with an outdated drum trap that prevented effective snaking and clearing of the blockage. Drum traps, while common in older plumbing installations, are prone to collecting debris and creating persistent drainage problems due to their design. Standard drain cleaning equipment cannot navigate these fixtures effectively. To resolve the issue permanently, removed the existing drum trap assembly and replaced it with a modern P-trap configuration. This required accessing the plumbing through the ceiling below the bathroom, creating an opening to reach the drain line
Performed routine maintenance on 17-year-old mini boiler system. Inspection revealed one heating element not functioning due to a faulty Triack not delivering proper voltage. System operating at approximately 50% capacity with only one functional element. Customer informed of findings and advised to obtain estimates for Triack and control board replacement, though indicated preference to continue primarily using mini split system.
Replaced leaking 50-gallon electric water heater with new unit featuring minimum 10-year warranty. Inspected well system during service, noting proper connection to existing plumbing infrastructure and ensuring adequate water pressure. Installation completed successfully, restoring hot water service to the residence.
Responded to "no heat" service call for a 36-year-old Heil furnace. Inspection revealed two popped rings on secondary heat exchanger, confirming heat exchanger failure. Equipment was tagged out of service due to safety concerns and scheduled follow-up with service advisor for replacement options.
Performed boiler maintenance inspection on Navien unit and identified severely melted heat exchanger requiring replacement. Tagged out boiler for safety and explained damage to customer. Submitted information for warranty claim and parts order; advisor scheduled to return with replacement options focusing on models with serviceable heat exchangers.
Responded to a water leak service call where the existing P-trap and dishwasher plumbing under the kitchen sink had failed. Successfully replaced the leaking P-trap assembly and completely repiped both the dishwasher water supply line and waste pipe, which required reconfiguration of obstructing water lines. Photographic documentation was taken of the cabinet access area and completed under-sink plumbing installation featuring the new PVC drainage system and copper supply lines with brass shut-off valve.
Responded to emergency service call for bathroom lavatory faucet that had broken off at the base. Shut off water supply to prevent further leakage, removed damaged faucet assembly, and installed new replacement fixture with proper compression fittings. Tested for proper operation and verified no leaks at connections.
Replaced failed 50-gallon electric water heater that was unable to maintain hot water for more than 1.5 showers. Installed new 50-gallon electric unit after diagnosing issues with heating elements and thermostats in the original system. Properly connected all copper lines and verified proper operation before completion.
Completed routine maintenance flush on A.O. Smith ProMax 50-gallon electric water heater that was exhibiting leakage. Inspected and serviced the associated expansion tank, pressure gauge, and copper piping connections. Resolved leakage issue and ensured proper system operation with all components functioning according to manufacturer specifications.
Completed installation of customer-supplied tub/shower trim with drain and overflow. Replaced one existing shower valve that was incompatible with new trim and installed new valve to accommodate second trim set. Successfully completed installation of both trim packages, ensuring proper function and appearance.
Completed scheduled maintenance on residential reverse osmosis water treatment system. Replaced three filters on one-year-old RO unit according to manufacturer specifications. System was tested after filter replacement and is functioning properly with no leaks observed.
Diagnosed and identified two separate leaks: a cracked pivot rod assembly causing water leak beneath bathroom sink and a faulty hose attachment under laundry sink. Provided customer with repair estimates for both issues, noting that hard water conditions are likely contributing to multiple faucet failures throughout the home. Customer will decide on proceeding with recommended repairs after consultation with spouse.