Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to a return service call for a leak underneath the kitchen sink originating from the garbage disposal. Upon inspection, determined that the disposal unit had become dislodged from its mounting assembly, likely disturbed during previous day's piping replacement work to the stack. Removed the garbage disposal unit, properly reinstalled it to the mounting ring, and securely tightened all connections to manufacturer specifications. Verified proper seal and tested unit operation to confirm leak was fully resolved.
Completed annual plumbing inspection in response to reported basement water intrusion initially suspected to be related to sump pump or well pump failure. Conducted comprehensive visual assessment of all plumbing systems and components including toilet tank mechanisms, water softening system, pressure tanks, and associated supply lines. Inspected toilet flush assembly components including fill valve, flapper mechanism, and supply connections which showed normal wear patterns and mineral deposits consistent with regular use. Evaluated whole-house Culligan water treatment system with dual softener tanks, digital control units, pressure tank, and interconnected piping including blue PVC supply lines with brass fittings and shut-off valves. All plumbing components, fixtures, water treatment equipment, and pressure systems on the property's internal plumbing side were found to be functioning properly with no deficiencies identified. Investigation determined that basement water issue was not
Responded to a water leak in the downstairs shower where the fixture would not shut off, requiring the main water supply to be turned off. Diagnosed a faulty Moen cartridge as the source of the leak and successfully replaced the cartridge, restoring proper function to the shower valve and eliminating the leak.
Responded to emergency water leak in basement caused by pinhole leaks in corroded copper supply line. Water was shut off to the home upon arrival. Performed temporary repair to damaged copper piping section to restore water service to the residence. Extensive corrosion and green patina observed on existing copper pipes indicating age-related deterioration. Installed flexible copper corrugated pipe section with brass compression fittings to bypass the compromised area. Secured new piping to structural framing with appropriate fasteners. Tested repair for leaks and restored water supply to the home. Provided estimate for complete copper repipe system replacement due to widespread corrosion throughout existing plumbing infrastructure.
Responded to no heat call at commercial restaurant facility with multiple levels and two furnace units. Diagnosed upstairs furnace unit (12 years old) and identified failed ECM blower motor as cause of heating failure. Removed access panel, inspected internal components and control board, documented findings with photos. Submitted warranty claim information to parts department for motor replacement and awaiting customer approval on pricing for repair.
Responded to kitchen sink drain leak caused by corroded cast iron pipe with visible hole in the line. Removed deteriorated cast iron piping from under kitchen sink and installed new PVC drain line connecting to existing basement stack. Replaced compromised drain assembly with code-compliant materials, ensuring proper slope and secure connections throughout the drainage system.
Completed water heater installation with gas line correction. Initial black iron gas piping configuration included two 45-degree fittings nippled together creating excessive tension and improper fit at connections. Re-piped gas line from gas valve upward, eliminating unnecessary fittings and ensuring proper alignment without stress on piping. Performed comprehensive leak check on all fittings back to manifold and verified water heater operation.
Responded to follow-up service call for leaking downstairs toilet with leak occurring between tank and bowl. Upon inspection, identified multiple deficiencies with existing toilet fixture that would require extensive repairs. Presented repair options versus replacement to customer. Customer elected to proceed with complete toilet replacement. Removed old toilet fixture and installed new white porcelain gravity-flush toilet with standard left-side flush lever. Ensured proper sealing between tank and bowl, verified secure mounting to floor flange, and tested for leaks. Confirmed proper flush operation and water fill cycle upon completion.
Responded to leaking expansion tank on in-floor heating system. Replaced expansion tank in confined space, discovered and repaired additional leak during installation. Tested all heating zones for proper operation, bled air from faucets, and verified system pressure and functionality upon completion.
Responded to service call for continuously running toilet. Upon inspection, discovered loose flush valve assembly under tank causing leak, along with faulty ball cock mechanism. Replaced complete flush valve assembly, ball cock fill valve, and flush handle to resolve running water issue. Significant water accumulation observed on bathroom floor, attributed to combination of prolonged toilet operation, tank condensation, and leaking tank bolts—pre-existing conditions prior to service arrival. All components tested and functioning properly upon completion.
Responded to water leak caused by mop sink drain failure in kitchen area above basement. Upon inspection, discovered the push gasket had pulled out of the sink drain assembly due to inadequate support of the two-inch drain pipe from below. Reinstalled drain gasket, secured proper support for the two-inch pipe from underneath, and performed leak test to verify repair integrity.
Responded to ongoing boiler leak that had been previously addressed by tightening valve handles. Upon inspection, discovered a pinhole leak above the bladder on the side of the expansion tank. Diagnosed failed expansion tank as the source of the recurring leak issue. Provided estimate for expansion tank replacement and collected partial payment. Scheduled return visit to install new expansion tank and complete the repair.
Completed comprehensive furnace tune-up on 18-year-old FRP unit. All routine electrical measurements verified within specifications. Cleared drain lines and removed and cleaned condensate trap. Inspection revealed dirty blower wheel and corroded burners requiring attention. Heat exchanger inspection showed no compromises or cracks. Secondary heat exchanger exhibited significant contamination and signs of moisture leaking, possibly from evaporator coil dripping over time. Discussed equipment age, current condition findings, and recommended obtaining updated replacement pricing before proceeding with any repairs or cleaning services given the unit's age and potential secondary heat exchanger concerns. Advisor visit scheduled for follow-up consultation.
Responded to upstairs toilet clogging issue. Upon arrival, found Gerber toilet plugged with toilet paper still present in bowl. Snaked toilet to clear obstruction and restore proper drainage. Tested flush operation after clearing; toilet now flushing properly with no blockage remaining.
Completed comprehensive boiler tune-up on IBC unit previously installed in October 2023. Removed and thoroughly cleaned flame sensor and routine maintenance components, performed detailed inspection of heat exchanger, and added cleaning tablet to condensate pump. Ran full system diagnostics and operational testing with all equipment functioning properly and within manufacturer specifications.
Disconnected plumbing from kitchen island in preparation for cabinet replacement, including capping off water supply lines and waste drain lines. Removed PVC connections and secured all plumbing to allow for safe cabinet removal and new island installation, with return visit scheduled to reconnect plumbing after new cabinetry is installed.
Responded to service call for leaking electric water heater with water discharge from bottom of unit. Removed failed water heater and installed replacement A.O. Smith electric water heater under parts warranty coverage. Completed full removal and replacement including all necessary connections to existing copper supply lines and electrical service, proper disposal of defective unit, and return of old water heater to shop with warranty documentation attached. Verified new installation for proper operation, tested all connections for leaks, and confirmed pressure tank and control system integration with new water heater. System restored to full operational status.
Responded to service call for water leaking in and around furnace. Upon inspection, identified failed seal between inducer motor and collector box, along with a compromised heat exchanger ring on deck causing water intrusion. Extensive rust and corrosion observed on furnace support framework and housing components, indicating prolonged moisture exposure. Documented equipment condition with photographs showing corroded metal surfaces, deteriorated seals, and water damage. Consulted with property contact on-site regarding findings and recommended furnace replacement due to heat exchanger failure and extent of water damage to critical components.
Responded to no heat call on approximately 9-year-old system with reports of complete system failure affecting both heating and cooling equipment. Upon arrival, discovered blown low voltage fuse on furnace. Performed thorough inspection of all low voltage wiring and connections, finding no visible damage or loose connections at the furnace. During diagnostic interview, homeowner reported that the system failure occurred immediately after attempting to activate the air conditioning unit. Proceeded to outdoor condenser unit for inspection. Testing revealed shorted contactor in the AC unit, which caused excessive current draw on the low voltage circuit when energized, resulting in the blown fuse at the furnace control board. Explained findings to homeowner, including the causal relationship between the failed contactor and the blown fuse. After receiving approval to proceed with repairs, replaced the defective contactor with new unit. Installed new low voltage fuse at furnace control bo
Responded to a leaking outdoor lawn faucet that had frozen and failed. Accessed the water supply line running through the attic/crawl space, removed the damaged frozen faucet assembly, and installed a new lawn faucet with proper connections to the existing copper supply line. Verified proper operation and no leaks upon completion.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.