Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to a bathroom sink drain obstruction. Upon arrival, found the pop-up assembly completely clogged and preventing drainage. Removed the existing pop-up assembly and installed a grid strainer style drain as a replacement to address recurring drainage issues. Performed three full-basin water tests to verify proper drainage and flow rate. Conducted thorough leak inspection of all connections with no leaks detected. System restored to full functionality.
Completed annual maintenance on residential water treatment system. Replaced iron filter cartridge in white cylindrical housing after 14 months of operation. Inspected water softener with digital control head, WaterTrol pressure tank, and associated copper piping connections for proper operation. All equipment functioning within normal parameters. System returned to service.
Diagnosed and replaced faulty diverter handle in commercial faucet assembly to restore proper water control operation. Installed new parts and verified hot and cold water shut-off valves functioning correctly. Completed installation ensures improved water flow efficiency and long-term operational reliability for the commercial sink station.
Responded to no heat call on 2008 furnace unit. Upon inspection, found system displaying high limit fault code. Tested all limit switches which passed diagnostics. Discovered improper wiring configuration with one wire disconnected from pressure switch and another wire incorrectly connected to wrong terminal on second pressure switch. Corrected all wiring connections per manufacturer specifications. Initial fault code cleared but system then generated limit switch open blower fault code despite inducer motor operating properly and pressure switch testing within normal parameters. Attempted system startup and furnace operated for approximately ten minutes before faulting again with same limit switch open blower fault code, though all components were functioning correctly. Determined control board was providing false fault readings and misinterpreting limit switch status. Recommended control board replacement to restore proper system operation. Ordered replacement control board and retur
Completed comprehensive plumbing inspection for rewards member with no issues identified. Evaluated piercing valve on humidifier supply line connected to furnace, which was previously reported as non-functional during heating system inspection. Documented existing plumbing infrastructure including copper supply lines, mounting hardware, kitchen fixtures, and faucet assembly. Provided estimate for humidifier replacement with recommendation to replace piercing valve during that service to ensure proper water supply connection and system functionality.
Completed scheduled cooling system maintenance visit on 20-year-old residential HVAC system. Performed comprehensive tune-up including cleaning of outdoor condensing unit, inspection of indoor furnace components, and operational testing of all system functions. All equipment found operating within normal parameters with no deficiencies noted at time of service.
Responded to service call for leaking shut-off valve on recently installed boiler system. Upon arrival, homeowner reported intermittent water leakage from valve handle that had not reoccurred during inspection. Documented existing plumbing configuration including brass manifold assembly with PEX connections and Webstone gas valve installation. Due to intermittent nature of leak and age of components, photographed affected area and submitted parts order for replacement shut-off valve and associated fittings. Recommended replacing entire section of supply line along with shut-off valve to ensure long-term reliability and prevent future leakage issues.
Completed comprehensive plumbing inspection of residential property. Successfully repaired malfunctioning faucet located adjacent to sauna room, restoring proper water flow and function. Documented existing water filtration and treatment system installation, including three-stage filter cartridge assembly, pressure expansion tank, and associated copper and PVC plumbing connections within exposed wall framing.
Completed comprehensive plumbing inspection of residential property with no known issues reported prior to visit. Inspected all accessible plumbing systems including water supply lines, drain waste vent piping, and shut-off valves throughout the property. Documented existing conditions with photographic evidence showing PVC drainage system configuration in utility area and water supply valve assembly displaying significant surface corrosion requiring future monitoring.
Responded to water heater overheating and leaking issue. Upon inspection, discovered failed temperature and pressure relief valve, pinhole leak in tank jacket above thermostat location, and completely burned out thermostat. Internal insulation showed water saturation from pressure relief valve discharge. Unit was originally installed under warranty and determined to be defective. Documented all damage with photographs showing frost buildup on failed thermostat and overall unit condition. Confirmed water heater qualifies for warranty replacement. Scheduled installation of new 50-gallon residential water heater and replacement of shut-off valve located after pressure tank to ensure proper system operation and safety compliance.
Responded to no heat call on Gibson natural gas furnace. Upon arrival, homeowner reported unit would run for only a couple minutes before shutting down and required toggling power switch to restart after extended idle periods. Initiated system startup and observed igniter failing to achieve proper glow intensity during ignition sequence. Electrical testing confirmed igniter was weak and operating below specifications. Visual inspection revealed component in deteriorated condition. Performed comprehensive system evaluation and found air filter completely plugged, restricting airflow. All other furnace components including blower motor, flame sensor, gas valve, and limit switches tested within normal operating parameters. Replaced failed hot surface igniter with new OEM component. Cycled system through multiple heating cycles to verify proper ignition sequence, flame establishment, and continuous operation. Unit now heating normally with all safeties functioning correctly.
Performed comprehensive HVAC system safety inspection and maintenance on air conditioning and make-up air systems. Replaced air filter and activated AC unit for operational testing. Inspected blower wheel and secondary components, noting minor buildup present. Verified evaporator coil condition (clean), tested blower capacitor (functioning properly), and confirmed condensate drain line clear. Proceeded to exterior unit where condenser coil was thoroughly cleaned and all components inspected. Reactivated system and conducted performance testing in 43°F ambient conditions, achieving satisfactory temperature drop. Occupant reported inadequate cooling capacity during peak summer conditions; recommended follow-up service call during warmer weather for accurate load testing. Conducted assessment of make-up air system to determine maintenance requirements. Identified belt and filter replacement needed for make-up air unit. Return visit scheduled to complete tune-up once parts are procured and
Completed comprehensive HVAC maintenance including safety inspection of furnace system, make-up air system tune-up, and exhaust fan service. Performed routine maintenance on both mini-split and standard split system units, replacing air filters and inspecting evaporator and condenser coils for debris blockage—both found to be in clean condition. Tested blower capacitor, which measured within acceptable parameters. Conducted exterior condenser coil cleaning and verified all electrical components operating to manufacturer specifications. Measured refrigerant pressures and temperatures; system appears adequately charged based on current readings, though ambient conditions limited full AC performance testing. Identified need for furnace air filter replacement requiring special order; return visit scheduled to complete equipment cleaning and filter installation once parts arrive.
Responded to water leak complaint in shower unit. Upon inspection, identified active leak occurring at back end of shower liner during operation. Traced source to shower valve assembly and discovered pinhole leak in valve body. Documented existing conditions with photographs showing white fiberglass tub/shower combination unit with three-handle chrome fixture configuration and evidence of water infiltration. Provided estimate for shower valve replacement to resolve leak issue.
Responded to no heat call on residential boiler system. Upon arrival, found boiler shut down due to low water pressure condition. Discovered auto fill valve was closed and system pressure had dropped below operating threshold. Attempted to restore water feed but found backflow preventer and auto fill assembly were seized and not functioning properly. Disassembled and freed both components to restore water flow to system. Successfully brought boiler pressure up to proper operating level, at which point unit fired and resumed normal heating operation. However, noted relief valve on backflow preventer was dripping following restoration of water pressure. Placed collection bucket beneath drip and advised homeowner of condition. Given that system is only two years old, prepared estimates for replacement of backflow preventer as standalone repair, as well as combination replacement of both backflow preventer and auto fill assembly. Submitted parts inquiry to verify potential warranty cover
Completed comprehensive duct cleaning service in conjunction with new HVAC system installation. Removed significant accumulation of dust, pet dander, and dog hair from ductwork and ventilation components throughout the system. Performed thorough vacuum extraction of debris from supply and return ducts, ensuring optimal airflow and indoor air quality for newly installed equipment.
Completed annual air conditioning tune-up and maintenance service on 2-year-old ICP system under membership agreement. Performed comprehensive inspection of outdoor condenser unit, applied foaming coil cleaner to remove accumulated dirt and debris from condenser coils and top grille to restore optimal heat transfer efficiency. Service was expedited due to scheduling constraints at the property.
Completed warranty repair on outdoor condenser unit by replacing defective condenser fan motor. Verified proper fan operation and system functionality upon completion. Unit is operating as expected with no further issues detected.
Responded to basement water leak affecting laundry area. Identified leaking water connection for washing machine and drain tub requiring replacement. Assessed property plumbing system and noted undersized 3/8" water lines throughout residence requiring complete re-piping. Documented conditions with photos and scheduled follow-up appointment for comprehensive bid on bathroom installation and drain line replacement.
Responded to a leaking water heater emergency and removed the failed unit. Installed a new 50-gallon electric water heater with expansion tank in the residential utility space, connecting all supply lines using PEX plumbing with proper hot and cold water configurations. Completed full system testing to verify proper heating operation and confirmed no leaks at connections or tank fittings.