Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to service call for compromised copper water line supplying refrigerator icemaker. Upon inspection, determined existing icemaker shut-off valve was broken and required replacement. Removed failed copper line and defective shut-off valve, then installed new quarter-turn ball valve with brass fittings in recessed wall box. Connected refrigerator to new water supply using braided stainless steel flexible supply line with proper compression fittings. Tested system for leaks and verified proper water flow to icemaker unit upon completion.
Completed annual plumbing inspection on one side of duplex unit. Identified and tightened loose packing on exterior faucet and secured loose handle on vanity faucet. Inspected water heater installation with copper supply lines and brass fittings, and verified shower fixture operation—all systems found to be in good working condition.
Completed comprehensive 8-12 point air conditioning tune-up on 6-year-old Lennox FRP system. Performed outdoor condenser cleaning, flushed interior condensate drain line, inspected air filter, replaced dehumidifier filter, and conducted full system operational testing to verify proper equipment performance.
Completed comprehensive preventive maintenance on both air conditioning system and boiler. The 14-year-old Carrier AC unit received full inspection including condenser coil cleaning, electrical testing with all readings within manufacturer specifications, air filter verification, condensate drain clearing, and refrigerant charge confirmation with proper temperature differential of 22-23 degrees. The recently installed boiler and water heater underwent routine maintenance including cleaning of standard components, condensate trap servicing, and ignition rod cleaning. Both systems were operationally tested and confirmed functioning properly with no issues identified.
Responded to two leaking outdoor faucets at rear of property. The right-side spigot exhibited a pencil-stream leak and required complete stem rebuild with replacement of all internal components. The left-side faucet showed severe leaking from the aerator, compounded by a garden hose being left connected through winter, causing freeze damage; replaced the aerator assembly. Customer opted for repair over full replacement to avoid interior wall access near occupied living space. Advised ongoing monitoring of both fixtures due to age and condition of existing hardware.
Completed comprehensive plumbing inspection for friends and family program. Inspected and verified proper operation of tankless water heater system with all copper supply lines, shut-off valves, and gas connections in good working condition. Examined water softener system and confirmed proper function. All under-sink plumbing including P-trap assemblies and supply lines inspected and found to be well-maintained with no leaks or deficiencies noted.
Completed preventative maintenance on residential cooling system. Cleaned outdoor condenser coil and inspected all electrical components and connections. Found severely restricted air filter caused by excessive portable humidifier use during winter months, resulting in blower motor strain and furnace displaying three error codes: two airflow errors and one limit error. Replaced air filter and cleared all error codes. Verified refrigerant charge within specifications with 20-degree temperature differential across evaporator coil. Provided homeowner education on proper humidifier usage, recommending exclusive use of existing whole-home humidification system to prevent future airflow restrictions. System restored to proper operation with adequate cooling performance and airflow.
Completed comprehensive preventive maintenance on furnace and air conditioning system. Performed full inspection of furnace, noting aging equipment with heat exchanger showing significant wear and deterioration. All other furnace components including electrical connections, gas valve, and blower assembly tested within manufacturer specifications. Air filter found clean and condensate drain line verified clear and flowing properly. Conducted air conditioning system maintenance including condenser coil cleaning and electrical component testing. Verified refrigerant charge and system pressures appropriate for current conditions. Measured temperature differential at 21 degrees, confirming proper cooling performance. All electrical connections and capacitors tested within acceptable parameters. Discussed equipment condition with homeowner regarding furnace age and heat exchanger concerns. Homeowner expressed interest in furnace replacement and scheduled follow-up consultation for equipmen
Responded to basement flooding emergency caused by water backing up from septic system overflow. Assessed the situation and determined blockage was either in the main sewer line exiting the house or in the line between the two septic tanks. Coordinated with property owner to arrange septic pumping service to evacuate tank contents, which will allow for proper diagnosis of the blockage location and determine whether the main line requires clearing or if the inter-tank line needs excavation and replacement. Documented site conditions including septic tank access point location for follow-up work.
Completed comprehensive air conditioning tune-up on Lennox outdoor condensing unit. Performed thorough cleaning of outdoor coil and cabinet, flushed condensate drain line at indoor air handler, and inspected air filter. System was operationally tested in maximum cooling mode and confirmed proper performance with all components functioning within normal parameters.
Performed comprehensive maintenance on 2019 Lennox air conditioning system including full component testing, coil cleaning, air filter replacement, and condensate drain line clearing. All system components tested within normal operating parameters with 20-degree temperature split confirmed. Addressed thermostat compatibility concern regarding recently installed M30 Wi-Fi thermostat; confirmed unit functions properly for heating and cooling operations despite Wi-Fi connectivity limitations, and provided upgrade options for smart thermostat which were declined.
Completed comprehensive plumbing inspection of residential property. Inspected PVC drainage system beneath floor structure, including trap configurations, horizontal drain lines, and brass floor drain connection point. All plumbing components, fixtures, and accessible piping were visually examined and found to be in proper working order with no leaks or deficiencies noted at time of inspection.
Performed comprehensive maintenance tune-up on 17-year-old Bryant air conditioning system. Replaced air filter, cleared condensate drain line, inspected electrical components, and cleaned condenser coil. Started system and verified operational performance with subcooling reading of 4-5°F and temperature split of 18°F across evaporator coil. Conducted UV dye leak inspection with no leaks detected at this time.
Responded to service call for furnace making excessive noise that started same morning. Upon inspection, diagnosed failing inducer motor with worn bearings causing abnormal operational sounds. Verified issue through system observation and audible assessment of component operation. Documented equipment model information and current condition with photographs for parts research and replacement options.
Completed comprehensive 12-month preventative maintenance on Gibson HVAC system, original to home since 2004. Performed outdoor condenser unit cleaning, removed debris and vegetation from around unit, flushed evaporator coil and condensate drain line inside furnace closet. Tested all electrical components, verified proper amperage draws, and confirmed operational functionality of heating and cooling systems. Documented equipment model and serial numbers with photographs for service records.
Completed comprehensive plumbing inspection as part of family rewards program, with HVAC system also evaluated during visit. Inspected all accessible plumbing fixtures and components including toilet installation, water supply lines, and drainage systems. All plumbing systems found to be in proper working condition with no issues identified or repairs required.
Responded to service call for water meter replacement coordination with municipal water authority. The existing shut-off valve before the meter required replacement to allow the city to install new meter. Coordinated water shut-off scheduling with municipality. Removed existing shark bite fittings on both sides of the water meter. Cut out two shark bite fittings and installed a new three-quarter inch ball valve on the house side of the meter. Replaced outdated shark bite connections with proper fittings to meet code requirements and ensure reliable long-term performance. Work completed in crawl space utility area with corroded existing copper piping. All connections tested and verified operational upon water service restoration.
Responded to boiler leak warranty call. Upon inspection, identified loose packing on ball valve as source of water leakage at packing nut. Tightened packing nut approximately 1/4 turn to secure seal. Performed preventive maintenance by inspecting and snugging down packing on all ball valves throughout system. Leak successfully resolved with no parts replacement required. System tested and verified operational with no further water discharge.
Completed preventative maintenance on 24-year-old R22 air conditioning system. Performed comprehensive AC tune-up including condenser coil cleaning, electrical measurements verification within manufacturer specifications, and installation of customer-supplied air filter. System operating properly with adequate cooling performance, appropriate refrigerant pressures for ambient conditions, and satisfactory temperature differential across evaporator coil.