The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to emergency water treatment system failure causing basement flooding. Successfully removed malfunctioning acid neutralizer unit from crawlspace that lacked bypass capability. Completed full repipe of water treatment system and installed new bypass configuration to allow future servicing without system shutdown. All PVC connections secured to concrete block walls with appropriate mounting hardware and tested for proper operation.
Responded to a leak occurring in interior piping when the outdoor spigot was activated. Upon inspection, identified the source as a loose packing nut on the gate valve controlling the outside faucet. Tightened the packing nut to stop the leak and restore proper function to the outdoor spigot system.
Responded to service call addressing multiple plumbing issues throughout the residence. Diagnosed and repaired Delta kitchen faucet experiencing reduced hot water flow, identifying a kinked supply line as the root cause. Assessed broken shower head in master bathroom where the tube fractured at the threaded connection point. Inspected Moen whirlpool tub faucet with active leak at handle assembly. Provided estimate for replacing shut-off valve under kitchen sink and repairing shower head assembly. Supplied separate estimate for complete whirlpool tub faucet replacement due to extent of wear and potential for continued leaking from handle mechanism.
Responded to no cooling complaint on 15+ year old residential air conditioning system. Upon arrival, discovered a gutter bracket had fallen onto the outdoor condensing unit during recent roof work, physically obstructing the condenser fan from spinning. Removed the foreign debris from the unit and verified fan operation. Performed complete electrical diagnostics on the system, confirming all voltage and amperage readings within manufacturer specifications. Measured supply and return air temperatures, verifying proper 20-degree temperature split across the evaporator coil. System restored to normal cooling operation with no additional repairs required.
Completed comprehensive AC tune-up on 5-year-old system including washing outdoor condenser unit, testing electrical components (all readings within manufacturer specifications), and verifying airflow with 20° temperature drop across evaporator coil. Advised customer of exterior water spigot leak behind handle, likely requiring gasket replacement, which customer indicated they will repair themselves.
Completed annual air conditioning tune-up and maintenance inspection. Verified air filter and evaporator coil were clear with proper drainage, confirmed blower assembly was clean and operating within specifications. Cleaned condenser coil, performed comprehensive electrical inspection with all components reading within normal parameters. System tested for 15 minutes under operating conditions, achieving optimal 20-22 degree temperature differential across the coil, confirming proper refrigerant charge and overall system performance.
Installed customer-supplied bathroom lavatory faucet with complete drain assembly and pop-up mechanism. Provided estimate for lavatory faucet replacement including two new shut off valves with supply lines, which was not approved at this time.
Responded to water leak emergency and discovered a 1/4 to 1/2 inch split in copper pipe caused by a failing ball valve on the irrigation line that was leaking through. Water supply to the affected area was shut off to prevent further damage. Removed the damaged section of copper piping and installed new copper pipe, then replaced the defective ball valve to restore proper function and eliminate the leak.
Responded to urgent no-cool call on recently installed EL18BCV unit displaying 411 error code for low pressure switch lockout. Upon arrival, found furnace filter completely plugged, causing severe airflow restriction and triggering system fault. Removed heavily soiled filter, installed new filter, and verified proper airflow at 1200 CFM for 3-ton system capacity. Connected refrigerant gauges and performed system diagnostics on R454B charge. Found unit running with elevated subcooling values, indicating overcharged condition. Carefully recovered excess refrigerant and precisely dialed in manufacturer-specified subcooling and approach temperatures per EL18 unit charging specifications, as these units require exact charge for proper operation. Verified system performance with 17-degree temperature split across evaporator coil, confirming adequate cooling capacity and proper refrigerant charge. System returned to normal operation with all fault codes cleared. Work completed under warranty
Responded to a water leak emergency caused by severely corroded washing machine supply hoses and valves. Upon arrival, found the main water supply had been shut off to prevent further damage. Inspection revealed both hot and cold washing machine valves had rotted out and were no longer serviceable. Replaced both the hot and cold water supply valves with new units to restore proper function and eliminate the leak. System tested and confirmed operational upon completion.
Responded to no cooling call on Lennox air conditioning unit that was tripping the breaker upon startup. Homeowner reported the issue occurred intermittently when the system sat idle for several days, typically tripping within five seconds of operation, but would run normally after resetting the breaker and attempting a second start. Performed diagnostic testing of all electrical components including contactor, capacitor, and compressor windings. All components tested within manufacturer specifications with no abnormal amperage draws detected during startup at time of inspection. Based on symptom pattern and diagnostic findings, determined the compressor was experiencing hard start conditions due to refrigerant migration during extended off cycles, causing liquid refrigerant to settle in the compressor. Installed hard start kit to assist compressor during startup and prevent nuisance breaker trips. Hard start kit provides additional starting torque to overcome liquid refrigerant in c
Completed comprehensive AC tune-up on single residential air conditioning unit, performing full disassembly to remove accumulated leaves and debris from condenser unit. Removed side panels and thoroughly cleaned condenser coil, inspected all electrical connections and wiring in outdoor unit confirming proper operation, flushed evaporator coil, verified blower speeds were correctly configured, and conducted system startup test confirming 22-degree temperature differential across the system with all components operating within normal parameters.
Responded to report of intermittent gas odor near furnace and exterior exhaust vent. Conducted comprehensive gas leak inspection using electronic gas detector throughout home, checking all gas piping, furnace interior, and heat exchanger area with no leaks detected. Performed furnace startup and combustion analysis test, measuring 10 ppm CO which is within normal operating parameters. Verified zero carbon monoxide presence throughout living spaces using CO detector. Noted faint residual gas smell in heat exchanger tubes immediately post-cycle, which is normal operation. Determined odor near exterior exhaust vent was likely combustion byproduct from normal furnace operation rather than gas leak. System operating safely with proper combustion and venting confirmed.
Completed comprehensive annual maintenance and tune-up on 8-year-old Bryant air conditioning system. Performed thorough inspection of outdoor condenser unit including electrical components verification, condenser coil cleaning, and wiring inspection—all components found operating within specifications. Indoors, verified fresh air filter, flushed evaporator drain line, inspected furnace electrical connections, and confirmed blower motor settings appropriate for cooling operation. System startup test achieved 21° temperature split across evaporator coil, confirming proper refrigerant charge and system performance. All maintenance items completed per agreement specifications with unit operating efficiently.
Responded to water leak reported between dual water heater installation and adjacent laundry room. Upon investigation, identified compromised hot water supply line within wall cavity that had also caused catastrophic failure of one water heater tank. Executed repairs to damaged hot water piping and isolated the ruptured water heater unit to prevent further water damage and restore system functionality to the remaining operational heater.
Responded to no-cool call on 10-month-old AC system. Homeowner reported unit running but no airflow from registers and had shut system down earlier in day after changing air filter that morning. Upon arrival, activated system and observed all components operating properly with furnace blower running and achieving 22° temperature split across evaporator coil. Inspected air filter and identified complete saturation with white mineral dust despite clean appearance. Determined contamination source as ultrasonic humidifier producing airborne mineral deposits that clogged filter media and restricted airflow. Educated homeowner on ultrasonic humidifier operation and mineral dust formation process. Homeowner agreed to discontinue humidifier use. Verified system continued cooling properly with adequate airflow. Deactivated humidifier and confirmed AC operating within normal parameters before departure.
Performed comprehensive AC system evaluation including inspection of Ritz coil and all major components. Filter, blower assembly, and evaporator coil were found clean and in good condition. Homeowner reported inadequate cooling performance from previous season. Conducted operational test which revealed suboptimal 12-degree temperature split across the evaporator. Connected refrigerant manifold gauges and confirmed system pressures appear low, even with condenser unit covered during testing. Inspected electrical components including dual capacitors and associated wiring, all connections secure and functioning properly. Recommended follow-up appointment to verify refrigerant charge and system pressures once ambient temperature reaches minimum 60 degrees for accurate diagnostics.
Performed comprehensive duct cleaning service on residential HVAC system including mobilization and setup. Inspected ductwork in response to reported dead animal odor near utility room and investigated potential animal entry points in ceiling and duct connections. Found no evidence of animal presence in accessible ductwork or disconnected components. Cleaned 15 openings including all supply and return ducts which contained accumulated dust, dirt, and debris. Utilized professional duct cleaning equipment to thoroughly remove contaminants from interior duct surfaces. Verified proper cleaning of all ductwork components and confirmed system cleanliness upon completion. Documented pre-cleaning conditions showing significant dust accumulation on galvanized metal ductwork and flexible ducting components, as well as attic space framing and insulation areas near duct system.
Replaced existing toilet with new standard height unit including wax ring, bolts, and complete installation. Due to proximity to wall, sourced and installed 10-inch rough-in toilet to ensure proper clearance. Replaced leaking shower hose at wall connection point. All fixtures tested and verified operational upon completion.
Completed comprehensive tune-up on 19-year-old FRP air conditioning system at duplex property, including cleaning of outdoor condenser unit, testing of all electrical components, and cleaning of indoor drain line. During inspection, observed system beginning to freeze up, indicating potential refrigerant or airflow issue requiring owner consultation for repair recommendations. Same technician will return to service second unit covered under membership agreement.