Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no cooling complaint on 10-year-old Carrier Infinity system. Upon inspection, diagnosed failed dual run capacitor reading zero microfarads, completely out of specification. Replaced defective capacitor with new turbo-rated unit, restored system to proper operation, and verified cooling performance through complete operational testing.
Responded to service call for malfunctioning exterior hose bib that was seized and inoperable. Upon assessment, determined existing spigot required complete replacement due to frozen valve mechanism. Procured and installed 18-inch frost-free sillcock to accommodate wall depth and provide proper drainage angle. Removed failed fixture, prepared mounting surface on brick exterior, and secured new anti-siphon outdoor faucet with appropriate weatherproofing measures to prevent future water intrusion.
Completed phone follow-up regarding previous estimate request. Customer has demolished property down to the studs and inquired about scheduling work to proceed with project. Documented callback request and contact information for estimate discussion. Photographed reminder note to ensure timely follow-up communication is completed.
Completed routine Family Rewards cooling maintenance visit on 2-year-old residential air conditioning system. Performed comprehensive AC tune-up including washing outdoor condenser unit, testing all electrical components, and verifying system performance. All electrical readings measured within manufacturer specifications, air filter found in good condition, and system achieved proper 20-degree temperature differential across evaporator coil, confirming optimal operation with no issues identified.
Responded to no cooling complaint on commercial showroom rooftop unit. Upon arrival, found system calling with blower operational but compressors failing to engage. Cycled power multiple times; compressors would run briefly before tripping on high pressure safety. Initially only one condenser fan motor would start during power cycles. Identified heavily fouled condenser coil as root cause of high pressure condition. Performed condenser coil cleaning, which restored proper airflow and system operation. Verified both compressors and condenser fans now operating correctly with normal pressures. Noted dirty air filters and worn fan belt requiring future replacement. System restored to full cooling capacity. Recommended comprehensive tune-up maintenance for this unit and secondary office RTU to prevent similar issues.
Responded to back cottage for leaking water heater supply valve. Upon inspection, discovered ball valve had developed a pinhole leak in the side of the valve body. Removed defective ball valve and old 90-degree elbow fitting by unsweating copper connections. Installed new press-fit 90-degree elbow and press-fit ball valve to eliminate leak and restore proper water supply control to tanked water heater unit. System tested and verified operational with no leaks present.
Responded to no cooling complaint on 10+ year old system blowing warm air. Diagnosed failed compressor capacitor reading zero microfarads. Replaced defective capacitor with new unit, restoring system operation. Verified proper function with 15-degree temperature split across evaporator coil and confirmed adequate refrigerant charge by observing condensation along suction line.
Responded to no-cool complaint on 10+ year old A/C unit that had capacitor replaced previously. Upon arrival, found thermostat set to 80° with ambient temperature below setpoint, preventing system operation. Performed comprehensive system evaluation including visual inspection of evaporator coils and refrigerant lines, verified all components operating properly, and connected manifold gauges to check system pressures. Refrigerant pressures within manufacturer specifications, achieving proper 15° temperature split across evaporator coil with no evidence of icing or airflow restrictions. All mechanical and electrical components functioning as designed. After discussion with homeowner regarding thermostat operation and temperature settings, determined issue was thermostat programming rather than equipment malfunction. System operating normally with no repairs required.
Completed comprehensive furnace and air conditioning tune-up on 4-year-old HVAC system. Performed thorough inspections of both units, verifying air filter and blower assembly were clean, all electrical connections and components within manufacturer specifications, and condensate drain lines clear and functioning properly. Cleaned outdoor condenser unit and verified all components operating correctly. Conducted extended operational testing of both heating and cooling modes for 15 minutes each, confirming proper performance with 55-60 degree temperature rise in heating mode and 22 degree temperature drop in cooling mode. Provided customer with findings and estimate for outdoor fan capacitor replacement as requested.
Responded to no cooling complaint on 10+ year old air conditioning system with frozen refrigerant line. Upon inspection, found evaporator coils heavily soiled with black buildup due to overdue air filter replacement. Performed complete system evaluation including coil cleaning, capacitor testing, and contactor inspection. Cleaned outdoor condenser coils and verified proper system operation. Obtained satisfactory temperature split across the system, confirming restored cooling capacity. Recommended seasonal furnace inspection for fall maintenance.
Performed air conditioning tune-up on outdoor condensing unit and identified dual-run capacitor measuring out of specification on both fan and compressor terminals. System maintained acceptable 22° temperature split across evaporator coil, and all other components operated within normal parameters. Documented equipment specifications with photographs and provided estimate for capacitor replacement to customer.
Completed comprehensive air conditioning tune-up on 19-year-old system. Removed condenser top panel and thoroughly rinsed condenser coil inside and out to remove debris and improve heat transfer efficiency. Performed full system diagnostics with all electrical and mechanical components testing within normal operating parameters. Cleared and treated condensate drain line to ensure proper drainage. Verified system performance with 20-degree temperature differential across evaporator coil, confirming optimal cooling capacity and refrigerant charge.
Completed annual AC tune-up on 4-year-old Lennox FRP system. Performed routine maintenance including cleaning components, inspecting all equipment connections and operational elements, and conducting operational tests. System is functioning properly with no issues identified.
Completed 8-12 AC tune-up on 7-year-old Guardian FRP system. Performed thorough cleaning of outdoor condenser unit, removing debris from coil fins and inspecting protective grille. Tested all electrical components including disconnect box, verified proper voltage and amperage readings, and confirmed operational status of compressor and condenser fan motor. Ran system through full cooling cycle to verify proper refrigerant charge and temperature differential across evaporator coil. All components operating within manufacturer specifications.
Responded to multiple water leak emergency behind furnace and water heater. Upon inspection, identified three separate leak sources: corroded copper fitting behind water heater, failed water meter spud connection, and deteriorating gate valve above furnace. The copper piping exhibited extensive corrosion with green verdigris and white mineral deposits indicating long-term moisture exposure and oxidation damage. Documented all leak locations with photographs showing the severity of deterioration on the copper pipes and brass fittings. Provided estimate for replacement of the water meter spud and removal of the compromised gate valve to resolve the active leaks and prevent further water damage to the mechanical room.
Responded to no hot water condition on 6-month-old boiler. Found display board completely black despite power present at unit. Diagnostic testing revealed blown fuse and visible burn damage on display board. Performed inline fuse test to isolate fault, which indicated short circuit originating from SIM board component. When SIM board was reconnected during testing, inline fuse immediately failed, confirming board-level short circuit. Documented damage with photographs showing burnt components on red PCB and affected display assembly. Completed parts order form for replacement display board and SIM board required to restore operation. Unit remains non-operational pending parts arrival and reinstallation.
Responded to a leaking shower valve within the wall cavity. Removed the existing failed valve assembly and installed a new two-handle tub and shower valve with chrome trim, including cross-handle controls and tub spout with diverter. Replaced the bathtub drain strainer and overflow cover plate to complete the fixture upgrade. All components installed to manufacturer specifications with a one-year warranty on parts and labor.
Responded to no hot water complaint and diagnosed failed gas valve on existing water heater. Removed and disposed of old unit, then installed new 40-gallon Bradford White gas water heater with standard atmospheric venting and 10-year warranty. Connected gas supply line, water supply and discharge piping, temperature and pressure relief valve with proper drainage, and verified all connections for leaks. Tested unit operation, confirmed proper ignition sequence, and ensured adequate combustion air and venting per manufacturer specifications.
Responded to commercial kitchen plumbing issue where drain piping under food prep sink repeatedly disconnected from the strainer assembly. Upon inspection, determined the sink strainer was defective and causing the piping failure. Replaced the faulty strainer basket and reinstalled the P-trap configuration with new PVC drain piping to ensure secure, leak-free connections. System tested and confirmed operational with no further disconnections.
Responded to emergency water treatment system failure causing basement flooding. Successfully removed malfunctioning acid neutralizer unit from crawlspace that lacked bypass capability. Completed full repipe of water treatment system and installed new bypass configuration to allow future servicing without system shutdown. All PVC connections secured to concrete block walls with appropriate mounting hardware and tested for proper operation.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.