Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no cooling complaint on 8-year-old central air conditioning system where outdoor fan was not spinning and unit was producing intermittent whooshing sounds. Upon inspection, diagnosed failed run capacitor as cause of system failure. Replaced defective capacitor with new unit, restoring proper operation to both indoor and outdoor components. Verified system performance with temperature split measuring approximately 20 degrees across evaporator coil, confirming adequate cooling capacity and proper refrigerant charge.
Responded to no cooling complaint on 28-year-old system. Upon inspection, discovered improperly wired dual run capacitor installed by third party—load line incorrectly connected to common terminal, causing ghost voltage to condenser fan motor. This resulted in fan operating at approximately 50% RPM continuously, leading to elevated head pressure and inadequate heat rejection. Corrected capacitor wiring to manufacturer specifications, restoring proper fan operation and system cooling. Noted significant rust and corrosion on fan grille and mounting components consistent with unit age and outdoor exposure. Refrigerant charge verified within acceptable range. Provided estimate for condenser fan motor replacement as preventive measure due to potential damage from prolonged operation at reduced speed. Customer declined immediate repair, opting to attempt self-installation; scheduled follow-up advisory appointment for technical guidance.
Performed preventative maintenance tune-up on 6-year-old Lennox air conditioning system. Conducted comprehensive inspection including washing condenser coil, testing all electrical components, and verifying system operation. All measurements and readings confirmed within manufacturer specifications, with unit operating properly upon completion.
Responded to no cooling complaint where system was short cycling, running 30-45 seconds before thermostat would kick out on delay and repeat the cycle. Performed diagnostic testing on outdoor unit including low voltage verification, secured connections with new wire nuts, and ohm tested contactor coil which measured 17 ohms (within specification) and drew 0.29 amps when energized. After systematically verifying all wiring at outdoor unit, furnace, and thermostat location, determined thermostat was faulty. Replaced defective thermostat with new Honeywell Home ProSeries T4 unit, verified proper wiring connections throughout system, and monitored operation for approximately 20 minutes to confirm proper cycling with temperature降cooling to setpoint and system shutting off as designed.
Performed furnace tune-up on a 32-year-old Comfortmaster unit as requested for home sale contingency. Electrical components tested and found within specifications. Critical safety issue identified: cracks discovered on heat exchanger, documented with photographs. Due to age of unit and severity of heat exchanger failure, coordinated same-day appointment with service advisor to discuss replacement options.
Responded to service call for assessment of water heater replacement and repair of two leaking PEX pipe connections. Conducted on-site inspection of existing water heater installation in basement utility area, documented current equipment condition and plumbing configuration with photographs. Examined two dripping PEX pipe connections requiring repair. Prepared comprehensive estimate including water heater replacement, PEX pipe leak repairs, and diagnostic work. Coordinated arrival notification with customer prior to arrival window.
Completed warranty repair on outdoor condensing unit experiencing instability due to steep grade erosion. Excavated and installed two rows of pressure-treated timber retaining wall to prevent equipment from sliding down slope. Unit was repositioned on gravel pad with proper drainage and structural support to ensure long-term stability and code compliance.
Responded to no cooling complaint where indoor temperature was rising despite thermostat being set to 71°F. Upon arrival, found outdoor unit not operating and discovered circuit breaker in off position supplying power to condensing unit. Reset breaker to on position and verified system operation with proper temperature drop across evaporator coil and normal cooling cycle. Advised occupants to monitor system performance and report any further issues.
Responded to no cooling complaint on 2-year-old air conditioning system. Upon inspection, found outdoor condenser coil completely blocked with accumulated dirt, dust, and debris, causing reduced airflow and inefficient operation. Thoroughly cleaned and rinsed condenser coil, removing heavy buildup from front panel and mesh screens. After cleaning, verified system operation with proper temperature split of 20° across evaporator coil and correct subcooling readings, confirming refrigerant charge within manufacturer specifications. Unit operating quietly with restored cooling capacity. Advised homeowner on importance of regular coil maintenance to prevent future performance issues.
Responded to no cooling complaint on two-year-old Trane central air system. Upon arrival, found outdoor condenser unit inoperative with furnace blower running but no cold air production. Discovered electrical disconnect had been left in the off position following recent siding work performed by contractors near the outdoor unit. Restored power by turning disconnect back on, verified proper system startup, and confirmed unit cycled normally with adequate cooling operation restored.
Responded to F20 error code on heat pump water heater indicating blocked condensate drain. Upon inspection, discovered gel-like substance accumulation in drain line due to improper installation without adequate venting. Installed proper vent on water heater drain pipe to resolve blockage issue and ensure proper condensate drainage system operation.
Responded to no cooling call on geothermal system. Customer reported manually jumping ECM blower motor for several weeks to initiate operation as control board was not sending signal to motor start wire. Upon arrival, found unit non-operational with no diagnostic lights illuminated, indicating failed control board. Tested compressor operation in heating mode - unit ran successfully. Attempted cooling mode operation resulted in pumps running 10-15 seconds before system lockout, but unable to determine specific fault code due to non-functioning diagnostic LED display. Verified condensate drain clear, checked loop pressures within normal range, and confirmed adequate refrigerant charge with no low pressure safety trips. Diagnosed primary failure as control board requiring replacement to restore ECM blower operation and proper system diagnostics. Advised customer that additional issues may be present but cannot be properly diagnosed until control board is replaced and diagnostic functions
Responded to emergency water shut-off situation caused by malfunctioning outdoor hose bib that would not close properly. Upon inspection, determined the hose bib was broken and required complete replacement. Successfully replaced the defective hose bib with new unit, restored water service to the home, and verified proper operation of the new fixture with no leaks detected.
Responded to outdoor hose bibb leak complaint and performed diagnostic assessment. Upon testing the exterior spigot, discovered a burst pipe and confirmed a 30-year-old gate valve was actively leaking. Replaced the defective hose bibb with new unit to restore proper function and eliminate water loss. Work was completed in basement utility area where supply lines were accessible.
Completed Family Rewards Program cooling maintenance visit on residential HVAC system installed in 2021. Performed comprehensive AC tune-up including cleaning routine components, testing all system parts, and running full operational diagnostics. System tested and verified operating within normal parameters with no issues found.
Kitchen sink drain was completely blocked with heavy grease buildup beyond the trap. Ran drain machine through the line approximately seven times to break through the solid obstruction and restore proper drainage. Flow successfully re-established.
Replaced leaking outdoor faucet with new freeze-resistant spigot featuring metal handle as requested. Installed new ball valve shut-off control inside basement crawl space to provide proper water isolation capability. Both fixtures were successfully installed and tested for proper operation with no leaks detected.
Responded to urgent water leak and flooding situation caused by pinhole leak in well line entering the residence. Upon arrival, confirmed water had been shut off at main but leak persisted from compromised pipe behind water heater. Inspected copper piping system, water heater connections, and filtration components to isolate source of active leak. Identified pinhole failure in well supply line requiring specialized well contractor for permanent pipe replacement and recommended immediate contact with well service provider to complete repair.
Responded to no cooling complaint on 33-year-old R-22 system experiencing freeze-up conditions and inadequate cooling performance. Upon arrival, unit was off per homeowner request to prevent potential furnace damage. Visual inspection revealed outdoor unit surrounded by debris including leaves and mulch accumulation around base and perimeter. Confirmed system age at 33+ years, significantly older than homeowner's initial estimate. Observed evidence of previous line set freezing based on customer report of frost formation prior to system shutdown. System exhibited minimal cooling output before freeze-up occurred. Preliminary assessment indicated low refrigerant charge and dirty condenser coil contributing to performance issues. Electrical components and wiring inspected during service call. Given the age of the equipment, R-22 refrigerant type, apparent refrigerant loss, compromised coil condition, and debris accumulation affecting airflow, recommended emergency replacement consulta
Responded to no cooling complaint on 6-year-old Carrier HVAC system. Upon inspection, diagnosed system as low on refrigerant charge. Discussed repair options and necessary steps with homeowner, who requested time to consider options due to limited summer occupancy. Provided detailed estimates for refrigerant leak detection, repair, and system recharge for customer review and decision.
©2026 Hurlburt. All Rights Reserved.