Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
The winter weather in Chippewa Falls makes it essential to have a dependable heating system because temperatures drop brutally low. When something goes wrong, you don’t want to risk damaging the system or injuring yourself with a DIY heating repair in Chippewa Falls. Instead, you need to call Hurlburt. We’ll send a trained technician to find and fix the underlying problem so that you don’t have to go without heat.
We’ll design a cooling system that perfectly matches your needs. This may look like a central setup with ductwork or a ductless mini-split using heat pump technology. The home’s square footage and layout impact choosing the right equipment. When something goes wrong, we’re just a phone call away. We’ll send a technician to implement a lasting solution that keeps the home cool and energy-efficient.
Our plumbers in Chippewa Falls, WI install water heaters, repair sump pumps, clear clogged drains and more. Emergency plumbing service is available for water leaks and burst pipes. We’re experts at finding and fixing hidden leaks beneath floors and behind walls.
You don’t want to ignore leaks and burst pipes because they increase the risk of water damage. Moisture buildup can lead to mold growth that causes respiratory and structural problems. Our solutions for leaks and burst pipes include pipe repairs, repiping and installing new shut-off valves. We’ll consider the leak’s location and severity to choose the best option.
Do you need to procure an EV charger upgrade? Hurlburt wants to help. We’ll match the charger to your charging needs and electrical system. Some homes require upgrades to their wiring to ensure compatibility with an EV charger. Some also require the installation of a dedicated circuit to feed the charging station. We’ll do a thorough inspection to see which upgrades your home needs.
We offer support for whole-home generators, smart home devices and other major electrical projects, too. We can even completely rewire your home. For example, if you’re still using outdated knob-and-tube wiring, we can upgrade it with modern grounded wiring. This makes the home safer by reducing the risk of electrical fires.
We’re the company that folks call when they need emergency HVAC in Chippewa Falls. We’ve helped numerous customers with furnace replacements after unexpected breakdowns. We’re also a trusted resource for achieving better indoor air quality in Chippewa Falls, WI. The humidity swings and seasonal allergens here contribute to stale, uncomfortable indoor air. With a whole-home air purifier in place, it becomes much easier to breathe easier and stay comfortable year-round.
We offer same-day service for emergency issues that need immediate attention, like burst pipes and refrigerant leaks. The technician who comes to your home will have gone through training and background checks. All HVAC installations we perform follow precise load calculations because we care about lasting performance.
Hurlburt isn’t your average home services company. We’re an all-in-one provider of electrical, HVAC and plumbing work. You won’t have to juggle multiple contractors just to get repairs or new installations. Homeowners frequently call us for heating and electrical upgrades. We love syncing thermostats and lighting with smart home systems to achieve better comfort and optimal energy efficiency.
Joining the Hurlburt Family Rewards Club gives you an easy way to save money on future repairs. Contact Hurlburt now to access professional solutions for plumbing, electrical, or HVAC in Chippewa Falls, WI.
Responded to no-cool condition on 26-year-old Heil R-22 residential air conditioning system. Upon arrival, confirmed 240V line voltage present at outdoor unit but condenser was not operating. Diagnosed tripped fuse at outdoor disconnect as cause of system failure. Performed electrical testing on compressor windings with results indicating proper operation. Verified refrigerant charge within acceptable parameters. Replaced failed fuse and restored power to condenser unit. System started and ran normally with proper supply voltage confirmed. No hard short detected during diagnostic testing. Advised homeowner that due to advanced age of equipment, intermittent electrical failures remain possible and system should be monitored closely for recurring issues related to aging components.
Responded to active water leak behind toilet with water supply shut off to home. Upon inspection, identified pinhole leak in copper elbow fitting within wall cavity behind toilet fixture. Removed compromised copper elbow and accessed plumbing below toilet level. Installed new PEX supply lines running from lower access point up through wall to toilet location. Installed new shut-off valve and reconnected to toilet supply line. Tested system for proper operation and verified no additional leaks present. Restored water service to home.
Responded to commercial RTU service call for limit switch replacement and filter maintenance. Upon arrival, procured and installed five new air filters and replacement limit switch. After installation, unit continued displaying error code 11, indicating economizer engaged for free cooling mode while cutting power to compressors. Condenser fan operation remained problematic with new limit switch installed. Through diagnostic troubleshooting, determined incorrect limit switch had been supplied—unit required normally closed switch rather than normally open configuration. Reinstalled original limit switch and implemented temporary repair by jumping second condenser fan motor from existing limit to ensure proper operation during cooling calls. Observed ongoing conflict between economizer and cooling system operation. During cooling demand, compressor would engage briefly before system switched to economizer free cooling mode, creating inefficient cycling pattern. Documented findings and
Responded to low water pressure complaint and discovered leaking pressure tank fitting causing basement flooding. Replaced failed fitting on top of pressure tank to stop active leak and restore system integrity. Assessed aging pressure tank showing significant corrosion and oxidation, along with multiple PEX line connections requiring repair. Recommended full pressure tank replacement and water repipe evaluation due to extent of system deterioration and ongoing reliability concerns.
Responded to no cooling complaint on approximately 15-year-old split system. Upon inspection, discovered air handler equipped with heating coil supplied by Munchkin boiler and separate A/C coil for cooling. Found blower pulley had completely sheared off, resulting in loss of airflow and subsequent freezing of indoor evaporator coil. Exterior condensing unit identified as 1994 Trane unit utilizing R-22 refrigerant, which tested critically low on charge. Evaporator coil exhibited heavy dust and debris accumulation due to inadequate filtration maintenance. System currently inoperable due to dual failures: mechanical failure of blower assembly and significant refrigerant loss in outdoor unit. Documented conditions with photographs showing failed blower pulley assembly and contaminated coil surfaces. Advised homeowner that both airflow restoration and refrigerant system repair required before normal operation can resume. Customer requested pricing for blower motor repair and full replacemen
Completed comprehensive air conditioning tune-up for non-member customer. Performed exterior condenser coil cleaning, conducted full electrical system testing with all readings within manufacturer specifications, and verified proper system operation. Air filter was found in excellent condition requiring no replacement at this time.
Responded to outdoor hose bibb leaking during use and behind the wall unit, an ongoing issue for approximately six years. Upon inspection, identified loose vacuum breaker as the source of the leak. Tightened and tested the vacuum breaker assembly to ensure proper seal and function. Leak successfully resolved. Additionally provided tankless water heater system information and estimate per customer request.
Responded to no cooling call on 8-year-old Bryant system. Upon arrival, found outdoor unit attempting to start but only producing humming sound while condenser fan ran. Diagnosed faulty capacitor preventing compressor from starting. Replaced defective dual run capacitor with proper replacement part, restored power, and tested system operation. Confirmed compressor and condenser fan motor operating correctly with proper amp draws and verified system cooling effectively.
Responded to no cooling complaint with water leaking from ceiling into living space. Upon arrival, located attic-mounted air handler and found evaporator coil with residual ice formation, indicating previous freeze-up condition. Most ice had already melted, causing the interior water leak. System had been shut down prior to arrival. Inspected evaporator coil and confirmed clean condition with adequate airflow, though noted system was operating without air filter installed. Performed refrigerant charge analysis on R-410A system and determined unit was significantly low on refrigerant, which was the root cause of coil freeze-up and subsequent water damage. Recharged system to manufacturer specifications and added UV dye to aid in future leak detection. Verified proper operation by measuring operating pressures, achieving subcooling readings of 11-14 degrees and supply air temperature drop of 20-23 degrees across the coil. Allowed system to run for 15-minute test cycle to confirm stable
Responded to no hot water complaint with circuit breaker tripping immediately upon reset attempt. Upon inspection, discovered 10-year-old tanked water heater was leaking and causing electrical fault. Removed and replaced failed unit with new water heater, reconnected copper supply and discharge piping, verified all connections for proper seal, restored power, and tested system operation to confirm hot water delivery and no further electrical issues.
Completed comprehensive AC tune-up on 10-year-old system as part of maintenance agreement. Performed outdoor unit cleaning, electrical testing with all readings within manufacturer specifications, air filter replacement, and verified proper system operation with 18-degree temperature drop across the coil.
Responded to a slow water leak at the shower handle that was previously identified during annual inspection. Encountered a stripped shower handle screw which required use of a screw extractor for removal. Successfully replaced the failed shower cartridge and tightened the shower head to eliminate the leak.
Completed comprehensive air conditioning tune-up on residential split system. Performed exterior coil cleaning on condenser unit, conducted full electrical testing with all readings within manufacturer specifications, and verified system performance with 19-degree temperature differential across the evaporator coil. Unit operating properly with no deficiencies identified.
Completed comprehensive plumbing inspection of residential property including evaluation of tankless water heater installation, visible plumbing connections, and related utility systems. All findings documented with photographic evidence and detailed in inspection report for customer review.
Responded to no-cool call on 15+ year old air conditioning system. Upon arrival, found outdoor condenser unit disassembled with fan motor and blades removed by homeowner prior to service visit. Customer was not present at time of inspection. Visually assessed condenser unit and documented extensive rust and corrosion throughout fan guard assembly and hardware, consistent with age and outdoor exposure. Unable to perform diagnostic testing or verify operational status due to missing components. Photographed equipment condition for service records.
Responded to no cooling complaint on 10+ year old air conditioning system. Upon arrival, performed system diagnostics and refrigerant charge verification. Found unit completely flat with no refrigerant charge remaining in system. Based on age of equipment, history of previous refrigerant recharge approximately 8 years prior, and current total refrigerant loss, provided replacement estimates to homeowner. Customer elected to obtain additional quotes for complete system replacement rather than pursue repair of existing unit.
Responded to no cooling complaint at modular home with 26-27 year old R-22 system. Upon arrival, started unit and confirmed all components operational including indoor blower. Connected manifold gauges and found suction pressure critically low at approximately 20 PSI, indicating significant refrigerant loss and system inefficiency. Verified thermostat accuracy and airflow through ductwork. Due to age of equipment, R-22 refrigerant phase-out, and cost-effectiveness considerations, recommended complete air conditioning system replacement rather than repair. Customer approved recommendation and scheduled follow-up consultation for equipment selection and installation.
Responded to no cooling complaint on recently installed 2.5-ton air conditioning system experiencing minimal airflow from supply vents and inadequate temperature drop. Upon inspection, determined blower speed had not been properly configured during initial installation. Adjusted and set blower speed to 1050 CFM to match system tonnage, restoring proper airflow and cooling performance.
Responded to no cooling complaint on 8-year-old GeoComfort geothermal system unable to maintain 75°F setpoint, with indoor temperature reaching 79-80°F. Found unit in WF lockout condition upon arrival. Reset system and unit fired up normally. Performed comprehensive diagnostics including refrigerant pressure testing with manifold gauges—all readings within normal parameters. Removed ductwork to inspect evaporator coil, which showed proper sweating pattern across entire surface indicating adequate refrigeration. Verified loop field pressures were within acceptable range. Consulted with technical support regarding intermittent lockout condition; discussed possibility of loop field pump or pump relay failure as potential cause. Cycled system multiple times and monitored operation for over 30 minutes. System ran continuously without fault and reduced indoor temperature by 2 degrees during observation period. Inspected Grundfos UPC-GEO pump control module and associated relay components. Al
Responded to water leak originating from upstairs shower affecting downstairs area. Upon inspection, identified broken shower arm as primary source of leak. Accessed plumbing through wall cavity, removed damaged section of pipe and faulty drop ell assembly. Installed replacement pipe section with new drop ell fitting, ensuring proper alignment and secure connections. Completed repair by installing new chrome shower arm and verified system integrity with no further leakage detected.