Hurlburt offers heating repairs, maintenance, installations, and replacements in Altoona. This ensures we can help keep our clients warm throughout the coldest days. We service furnaces, boilers, and ductless systems, making it easy to get assistance no matter what system you have.
It’s frustrating and concerning when you realize your heating system is experiencing issues or nearing its end. Our various heating solutions can restore warmth to your home whether you want an upgrade or to fix an issue. We offer standard and emergency HVAC assistance in Altoona.
Heating solutions we provide include:
Hot summer days require having cool, conditioned air flowing through your home. Our team can help make that happen whether you have a ductless system or central AC.
When summer approaches, the days become longer, and the temperatures rise, you need HVAC technicians you can count on. We tackle large and small projects, including installations, replacements, maintenance, and repairs. Our team arrives in fully stocked vans, ready to address any air conditioning situation you’re experiencing.
Cooling solutions we supply include:
Your plumbing system goes through significant wear and tear on a daily basis, especially in the kitchen and primary bathroom. The older the system, the more problems it may experience. Our plumbers in Altoona can address any issue with your system.
When you notice problems with your plumbing, it’s understandable that you don’t want to wait long for help. You can rely on our team for prompt, efficient repair services that help the water flow freely once again. Installations and maintenance are also available.
Plumbing solutions we offer include:
Our electricians in Altoona deliver a wide range of electrical services, including installing EV chargers and whole-home generators. They also provide maintenance, replacements, and repairs, ensuring a comprehensive approach to care for your electrical system.
Homeowners should never attempt any electrical projects on their own. It could lead to personal injury, fires, and even explosions. Our experienced team can perform any project, prioritizing safety and functionality.
Electrical solutions we provide include:
There’s a lot to love about living in Altoona from hanging out at Lake Altoona Park to dining at local restaurants. After a fun day, you don’t want to deal with a problem with one of your major home systems. Thanks to our multiple services, Hurlburt can help make your house safer, more comfortable, and more functional.
No matter where you live in Altoona, our plumbers, electricians, and HVAC technicians can assist you with your home needs. You’ll find our trucks in several local neighborhoods, including:
Our more than 65 years of industry experience means you can count on us to provide consistent, exceptional service. We employ a team of skilled technicians, electricians, and plumbers who love what they do, and it shows. Many of our clients have written positive online reviews about Hurlburt over the years. We invite you to read what they’ve had to say so you can know what to expect during your own appointment. Welcome to the Hurlburt family!
Contact Hurlburt today for outstanding plumbing, electrical, and HVAC services in Altoona.
Hurlburt Heating & Plumbing has completed 20 jobs in Altoona, WI in June 2026.
The most recent job was on June 30, 2026.
Responded to no cooling complaint on aging R-22 air conditioning system. Upon arrival, observed condenser fan attempting to start then stopping, with unit humming and blowing warm air only. Diagnosed failed capacitor preventing proper compressor and fan motor operation. Provided estimate for capacitor replacement and discussed system age, R-22 refrigerant phase-out implications, and replacement considerations with homeowner. Customer elected to schedule comfort advisor consultation for system replacement options given recent furnace upgrade and desire to update cooling equipment. Documented findings with photos and forwarded capacitor repair estimate. Unit remains non-operational pending customer decision.
Responded to no cooling complaint on residential HVAC system. Upon arrival, discovered blown 3-amp low voltage fuse at furnace panel and corroded thermostat batteries. Investigation revealed primary failure caused by damaged low voltage thermostat wiring at exterior location with exposed bare conductors, likely from weed trimmer contact. Secondary damage identified to furnace transformer resulting from oversized fuse installation during troubleshooting attempt. Outdoor condenser coil found heavily restricted with debris accumulation. Replaced 3 feet of damaged thermostat wire at exterior run and added insulation to exposed suction line. Performed complete condenser coil cleaning to restore proper airflow. Replaced failed transformer and installed correct amperage fuse at furnace. Inspected all electrical components and connections for proper operation. Verified system operation through extended run cycle of 20-30 minutes. Confirmed proper condensate drainage and measured 20-degree t
Responded to service call for residential oil furnace system experiencing blower failure. Upon inspection, identified failed blower motor with oil leakage and broken blower wheel requiring immediate replacement. Removed defective components and installed new blower motor and wheel assembly. After installation, started and tested the air conditioning system to verify proper operation. System ran normally with no abnormal blower noise or performance issues observed at time of departure.
Responded to no cooling complaint on older wall-mounted mini split system at bed-and-breakfast property. Upon inspection, found indoor air filters and outdoor condenser coil heavily clogged with dust and debris. Cleaned filters and condenser coil, then tested system on maximum cooling which resulted in evaporator coil freezing. Connected manifold gauges and confirmed system was low on refrigerant charge. Discussed findings with property owner, presenting repair versus replacement options. Due to active guests on property, owner requested immediate repair to restore cooling capacity. Added refrigerant to manufacturer specifications and tested system operation. Unit achieved proper cooling temperatures and maintained stable operation. Coordinated with service advisor to schedule estimate for new mini split replacement system.
Responded to a clogged basement utility sink drain. Upon inspection, found significant accumulation of lint and debris causing complete blockage of the drain assembly. Removed the clog by extracting the matted fibrous material from the drain system, restoring proper drainage function to the utility sink.
Performed comprehensive AC tune-up on residential system. Inspected indoor unit finding air filter, blower assembly, and evaporator coil clean with proper condensate drainage. Evaluated outdoor unit with capacitor and contactor in good condition and all electrical connections within manufacturer specifications. Measured system performance revealing low refrigerant charge with only 5-10 degree temperature split across evaporator coil. Added approximately one pound of R-410A refrigerant to system per customer request. Verified proper operation with temperature split exceeding 20 degrees upon completion, confirming system returned to optimal cooling performance.
Performed comprehensive AC tune-up on Lennox system. Upon arrival, conducted initial consultation and system assessment. Inspected air filter and found it heavily soiled; replaced with new filter. Examined blower assembly, confirming proper balance and cleanliness. Verified evaporator coil condition and confirmed proper condensate drainage operation. Inspected outdoor condenser unit and identified significant debris accumulation restricting airflow through coil fins. Performed electrical testing on all system components, confirming voltage, amperage, and capacitor readings within manufacturer specifications. Conducted operational test with 15-minute runtime, measuring 23-24 degree temperature differential across system, indicating optimal cooling performance. All components functioning properly with no deficiencies noted.
Performed Family Rewards cooling maintenance visit and addressed water leakage concern from furnace. Upon arrival, discovered pool of water at furnace base caused by clogged evaporator drain line and dirty air filter. Conducted complete AC tune-up including inspection of blower assembly and evaporator coil, both found to be in satisfactory condition. Performed electrical diagnostics on outdoor condensing unit with all readings within manufacturer specifications. Condenser coil confirmed clean with adequate airflow. Replaced air filter and successfully cleared evaporator drain line obstruction, restoring proper condensate drainage from drain pan. Ran system through complete operational test cycle for 15 minutes, confirming proper cooling performance with temperature split exceeding 16 degrees across evaporator coil. All components operating within normal parameters upon completion.
Completed comprehensive air conditioning tune-up and maintenance service. Tested system operation and confirmed proper cooling performance with good temperature drop in basement zone. Inspected air filter and verified clean condition. Cleared condensate drain line to ensure proper drainage and prevent water backup. Proceeded to outdoor unit where condenser coil was thoroughly washed to remove accumulated dust and debris from heat exchanger fins. Inspected all exterior components including fan assembly, refrigerant lines, and electrical connections for proper operation and condition. Unit is operating efficiently with all systems functioning within normal parameters.
Responded to a water leak emergency in the basement where a pinhole leak was identified in the copper piping located before the pressure tank on the well system. Water supply to the home had been shut off prior to arrival. Upon inspection, confirmed the pinhole leak in the copper pipe section between the well pipe and pressure tank, which had caused significant rust staining on the surrounding walls and surfaces. Removed the compromised section of copper piping and installed new copper pipe with proper fittings. Restored water pressure by turning the pressure tank back on, performed a thorough leak check of the repair area, and tested water flow at the kitchen faucet to verify proper system operation and pressure restoration.
Completed comprehensive air conditioning maintenance on aging system approximately 30-40 years old. Inspected and tested all major components including contactor, which showed significant wear, and verified dual capacitor that had been previously replaced. Measured compressor amperage at 1.88A using digital multimeter to assess system performance. Inspected attic-mounted air handler, ductwork, and condensate drainage system. Noted newer furnace installation in contrast to aging AC components. System operational at time of service completion, though advanced age and worn contactor condition were documented for property disclosure purposes.
Completed comprehensive preventive maintenance on a 2005 Trane R-22 air conditioning system as part of a recurring maintenance agreement. System is currently operational with an 18°F temperature split across the evaporator coil, though refrigerant charge appears slightly low. Inspected outdoor condenser unit, which showed normal wear consistent with age, and evaluated dual-run capacitor showing corrosion and weathering on terminals. No immediate operational failures detected at this time. Discussed system replacement options with homeowner, highlighting benefits of upgrading from aging R-22 equipment to newer, more energy-efficient technology that would provide quieter operation and improved long-term reliability.
Responded to no cooling complaint on four-year-old system originally installed by our company. Previous contractor had identified low refrigerant charge but declined to service due to warranty concerns. Connected manifold gauges to outdoor condenser unit and confirmed system was operating with insufficient refrigerant charge. Reviewed warranty coverage details and available repair options with homeowner. Recharged AC system to proper operating levels and injected UV leak detection dye into refrigerant circuit to facilitate future leak identification if issue recurs. Verified unit returned to normal cooling operation before departure. System cooling properly upon completion.
Performed comprehensive air conditioning maintenance on a 2018 Goodman condenser unit. Addressed cabinet integrity issues by installing replacement screws to secure loose panels and stabilize the frame. Tested the dual run capacitor, confirming proper operation at 44.8/5.0 µF within manufacturer specifications of 45/5 µF. Verified refrigerant charge with an 18°F temperature split indicating adequate system performance. Cleaned condenser coils and inspected all major components. System is currently operating within normal parameters, though cabinet construction quality warrants monitoring during future service visits.
Installed new smoke detector on kitchen rooftop unit to ensure proper fire safety compliance. Mounted detector securely to RTU housing and verified electrical connections. Performed operational test of cooling system to confirm equipment functionality following installation. All components tested and verified working properly upon completion.
Replaced failed blower motor on rooftop make-up air unit and reset control system. Upon completion, performed full operational testing to verify all components cycled properly and unit returned to normal operation.
Responded to service call for kitchen plumbing issues involving a dripping faucet and leaking dishwasher. Upon inspection, identified active leak at faucet stem and water seepage from dishwasher door seal. Removed existing defective faucet fixture and installed new replacement unit to eliminate leak at sink. Advised homeowner to contact appliance specialist regarding dishwasher replacement due to door seal failure. Documented completed installation with photos of work area.
Responded to callback for exhaust hood interlock fault created during previous site visit. Diagnosed MUA interlock issue preventing damper operation on makeup air unit. Investigated VFD power loss and confirmed absence of 120V supply from control panel to drive. Inspected relay contactors RA-1, RA-2, and RA-4 in electrical control panel and associated terminal block wiring. Documented equipment conditions and coordinated follow-up requirements to restore full system operation and prevent weekend shutdown.
Completed comprehensive AC tune-up including inspection of all major system components. Indoor unit inspection revealed air filter requiring replacement soon, which homeowner will handle independently. Blower assembly found clean and properly balanced, evaporator coil clean with proper condensate drainage confirmed. Outdoor condenser unit inspected and cleaned, with all routine components checked for proper operation. System operational testing conducted with 15-minute runtime, achieving over 20-degree temperature split indicating optimal cooling performance. All systems functioning within normal parameters.
Responded to warranty callback for downstairs toilet continuing to make running noises after previous service visit. Upon inspection, determined the fill valve was operating sporadically, causing the persistent noise issue. Removed the defective fill valve and installed a new replacement unit. Tested toilet operation to verify proper fill cycle and confirm elimination of running water sounds. System now functioning correctly with no further issues detected.
©2026 Hurlburt. All Rights Reserved.