Hurlburt offers heating repairs, maintenance, installations, and replacements in Altoona. This ensures we can help keep our clients warm throughout the coldest days. We service furnaces, boilers, and ductless systems, making it easy to get assistance no matter what system you have.
It’s frustrating and concerning when you realize your heating system is experiencing issues or nearing its end. Our various heating solutions can restore warmth to your home whether you want an upgrade or to fix an issue. We offer standard and emergency HVAC assistance in Altoona.
Heating solutions we provide include:
Hot summer days require having cool, conditioned air flowing through your home. Our team can help make that happen whether you have a ductless system or central AC.
When summer approaches, the days become longer, and the temperatures rise, you need HVAC technicians you can count on. We tackle large and small projects, including installations, replacements, maintenance, and repairs. Our team arrives in fully stocked vans, ready to address any air conditioning situation you’re experiencing.
Cooling solutions we supply include:
Your plumbing system goes through significant wear and tear on a daily basis, especially in the kitchen and primary bathroom. The older the system, the more problems it may experience. Our plumbers in Altoona can address any issue with your system.
When you notice problems with your plumbing, it’s understandable that you don’t want to wait long for help. You can rely on our team for prompt, efficient repair services that help the water flow freely once again. Installations and maintenance are also available.
Plumbing solutions we offer include:
Our electricians in Altoona deliver a wide range of electrical services, including installing EV chargers and whole-home generators. They also provide maintenance, replacements, and repairs, ensuring a comprehensive approach to care for your electrical system.
Homeowners should never attempt any electrical projects on their own. It could lead to personal injury, fires, and even explosions. Our experienced team can perform any project, prioritizing safety and functionality.
Electrical solutions we provide include:
There’s a lot to love about living in Altoona from hanging out at Lake Altoona Park to dining at local restaurants. After a fun day, you don’t want to deal with a problem with one of your major home systems. Thanks to our multiple services, Hurlburt can help make your house safer, more comfortable, and more functional.
No matter where you live in Altoona, our plumbers, electricians, and HVAC technicians can assist you with your home needs. You’ll find our trucks in several local neighborhoods, including:
Our more than 65 years of industry experience means you can count on us to provide consistent, exceptional service. We employ a team of skilled technicians, electricians, and plumbers who love what they do, and it shows. Many of our clients have written positive online reviews about Hurlburt over the years. We invite you to read what they’ve had to say so you can know what to expect during your own appointment. Welcome to the Hurlburt family!
Contact Hurlburt today for outstanding plumbing, electrical, and HVAC services in Altoona.
Hurlburt Heating & Plumbing has completed 20 jobs in Altoona, WI between October 2025 and November 2025.
The most recent job was on November 2, 2025.
Hurlburt Heating & Plumbing has completed 427 jobs in Altoona, WI in the last 12 months. The first job there was in October 2015.
Diagnosed intermittent heating issue on 8-year-old furnace that was shutting off at night. After comprehensive testing, identified faulty gas valve failing to send gas to burner despite receiving power. Replaced gas valve, calibrated gas settings, and verified proper system operation with no further heating interruptions.
Performed comprehensive preventive maintenance on 20-year-old Distinctions furnace system. Inspected all routine components which were found to be within manufacturer specifications. Heat exchanger was in excellent condition with no signs of deterioration. Unit operated properly through first and second stage testing with no issues detected.
Completed furnace tune-up maintenance as per service agreement. Inspected heat exchanger with no concerns found. Observed furnace operation for 15 minutes after servicing with system functioning properly. Additional inspection of water heater and water treatment system was performed with documentation via photos.
Completed gas valve replacement on heating system that presented with fluctuating pressure issues. Upon installation of new valve, discovered and removed multiple stuck sliders in the tube between orifice and gas valve that were impeding proper operation. Conducted thorough inspection of heat exchanger integrity via video inspection and blower removal, confirming no compromises to system components. System now heating properly.
Responded to no heat call for aging furnace system. Diagnosed faulty ignitor causing furnace cycling issues. Discovered significant heat exchanger corrosion and failing inducer and blower motors. Installed universal replacement ignitor to restore temporary heat operation and recommended complete system replacement due to multiple component failures and extensive corrosion observed.
Performed scheduled furnace tune-up service. Replaced customer-supplied dirty air filter, tested all components finding them within specifications. Inspected heat exchanger (no compromises), verified proper gas pressure, and confirmed system operation with a 60-degree temperature drop during 15-minute test run.
Performed annual furnace tune-up. Replaced customer-supplied dirty air filter. Completed full system inspection including heat exchanger integrity check, combustion analysis, and vent system assessment. All components found clean and within specifications. Verified proper operation with 60° temperature rise during extended 15-minute test run. System functioning properly with no issues identified.
Responded to customer concern about furnace noise and short cycling. Upon inspection, confirmed inducer noise is normal for the trailer home unit and explained operation to customer. Adjusted blower fan speed which was set excessively high, improving noise level while maintaining proper cooling performance. Determined thermostat placement may be causing perceived short cycling due to localized air flow affecting temperature readings.
Responded to a furnace service call requiring a gas valve replacement. Removed the defective gas valve and installed a new one on site, utilizing parts available from the service vehicle. Verified proper electrical connections according to manufacturer's wiring diagram and confirmed system operation after installation.
Responded to no-heat call for 20+ year old Gibson furnace. Diagnosed intermittent control board failure with pressure switch fault code. Upon inspection, discovered massive hole in heat exchanger, requiring immediate equipment shutdown and red-tag. Tagged out unit for safety concerns, documented damage with photos, and scheduled service advisor consultation to discuss replacement options versus heat exchanger and board repair.
Performed comprehensive maintenance on two older Ruud furnaces. Both units operating correctly for their age with no current issues. Noted galvanized flaking on upstairs unit's heat exchanger (no holes present) and documented visible corrosion along metal seams with photos. Replaced batteries in downstairs thermostat displaying low battery warning and recommended filter replacement for both systems.
Responded to no heat call. Upon arrival, furnace started without issue. Inspected system and identified weak inducer motor that is over-amping and producing loud noise. Performed combustion test showing 89% efficiency with 39 ppm CO. Customer has new baby and elected to postpone repairs. Provided repair options and offered to schedule service advisor appointment.
Diagnosed 2018 gas furnace operating with insufficient heat output. System was running but delivering only 65°F air. Inspected gas valve operation and confirmed pressure fluctuation during operation cycles. After consulting with technical support, determined gas valve malfunction was the root cause. Successfully replaced defective gas valve to restore proper heating function.
Responded to no heat complaint for a 30-year-old dual-zone HVAC system. Diagnosed failed collector box on one furnace, with pressure switches and tubing filled with water, preventing proper heating of approximately half the house. System evaluation confirmed end-of-life equipment condition. Homeowners were briefed on findings and scheduled for replacement equipment consultation.
Responded to no-heat call for 25-year-old furnace in basement. Diagnosed issue as disconnected pressure switch tubing due to degradation. Reattached tubing and performed combustion testing which initially showed borderline CO readings (below 100 ppm airstream, 3 ppm on first test, zero on subsequent tests). Customer indicated plans to replace both furnace and AC system.
Responded to a no heat call for a 10-year-old furnace. Diagnosed a flame sensor reading out of specification and a gas valve receiving 27V but failing to open. Demonstrated the system malfunction to homeowner Tom using a contactor to visually confirm voltage supply to the gas valve. Completed a comprehensive tune-up of the furnace components and discussed replacement options with the customer.
Performed routine maintenance on 2-year-old Lennox high-efficiency furnace. Conducted electrical diagnostics with multimeter and inspected blower wheel assembly, confirming proper system operation. No issues identified during service; system functioning as designed.
Removed seized non-functional garbage disposal unit from kitchen sink. Installed new replacement garbage disposal system with proper connections to existing PVC plumbing. Verified proper operation and drainage after installation with no leaks observed.
Performed comprehensive plumbing inspection as requested by seasonal residents preparing for winter departure. Identified and remedied failed wax ring on powder bath toilet - pulled and reset fixture. Provided customer education regarding proper shutdown procedures for the reverse osmosis system and verified proper functioning of water softener unit. All plumbing systems now operating correctly.
Performed semi-annual Family Rewards maintenance on Lennox furnace system. Cleaned flame sensor, verified proper condensate drainage, replaced air filter, checked blower wheel, and inspected electrical components (all within specification). System started properly with 55° temperature rise. Customer reported intermittent connectivity issues with Lennox home app; confirmed all software updates were current and suggested reinstalling application as potential solution.