Hurlburt offers heating repairs, maintenance, installations, and replacements in Altoona. This ensures we can help keep our clients warm throughout the coldest days. We service furnaces, boilers, and ductless systems, making it easy to get assistance no matter what system you have.
It’s frustrating and concerning when you realize your heating system is experiencing issues or nearing its end. Our various heating solutions can restore warmth to your home whether you want an upgrade or to fix an issue. We offer standard and emergency HVAC assistance in Altoona.
Heating solutions we provide include:
Hot summer days require having cool, conditioned air flowing through your home. Our team can help make that happen whether you have a ductless system or central AC.
When summer approaches, the days become longer, and the temperatures rise, you need HVAC technicians you can count on. We tackle large and small projects, including installations, replacements, maintenance, and repairs. Our team arrives in fully stocked vans, ready to address any air conditioning situation you’re experiencing.
Cooling solutions we supply include:
Your plumbing system goes through significant wear and tear on a daily basis, especially in the kitchen and primary bathroom. The older the system, the more problems it may experience. Our plumbers in Altoona can address any issue with your system.
When you notice problems with your plumbing, it’s understandable that you don’t want to wait long for help. You can rely on our team for prompt, efficient repair services that help the water flow freely once again. Installations and maintenance are also available.
Plumbing solutions we offer include:
Our electricians in Altoona deliver a wide range of electrical services, including installing EV chargers and whole-home generators. They also provide maintenance, replacements, and repairs, ensuring a comprehensive approach to care for your electrical system.
Homeowners should never attempt any electrical projects on their own. It could lead to personal injury, fires, and even explosions. Our experienced team can perform any project, prioritizing safety and functionality.
Electrical solutions we provide include:
There’s a lot to love about living in Altoona from hanging out at Lake Altoona Park to dining at local restaurants. After a fun day, you don’t want to deal with a problem with one of your major home systems. Thanks to our multiple services, Hurlburt can help make your house safer, more comfortable, and more functional.
No matter where you live in Altoona, our plumbers, electricians, and HVAC technicians can assist you with your home needs. You’ll find our trucks in several local neighborhoods, including:
Our more than 65 years of industry experience means you can count on us to provide consistent, exceptional service. We employ a team of skilled technicians, electricians, and plumbers who love what they do, and it shows. Many of our clients have written positive online reviews about Hurlburt over the years. We invite you to read what they’ve had to say so you can know what to expect during your own appointment. Welcome to the Hurlburt family!
Contact Hurlburt today for outstanding plumbing, electrical, and HVAC services in Altoona.
Hurlburt Heating & Plumbing has completed 20 jobs in Altoona, WI in November 2025.
The most recent job was on November 16, 2025.
Hurlburt Heating & Plumbing has completed 427 jobs in Altoona, WI in the last 12 months. The first job there was in October 2015.
Responded to no-heat call for 3-year-old furnace system. Diagnosed issue with incomplete burner ignition where only 2 of 3 burners were lighting. Removed spider web obstruction from final burner orifice, cleaned all burners/orifices, and replaced heavily clogged air filter that was being pulled into blower. Verified proper thermostat wiring and programming. Tested system through multiple cycles confirming proper operation including second stage activation.
Performed comprehensive duct cleaning service to address significant dust and debris accumulation observed in the HVAC ductwork. Removed extensive buildup of dust, cobwebs, and lint deposits that had formed throughout the spiral metal ducts, restoring proper airflow and improving system efficiency.
Diagnosed leak coming from customer's lavatory faucet rather than previous plumbing work. Determined existing faucet was failing and causing the leak. Removed old fixture and installed new customer-purchased replacement faucet, resolving the issue completely.
Responded to service call for 20-year-old furnace not running despite pilot light being on. Diagnostic testing revealed transformer receiving 120V but not outputting required 24V to engage gas valve. Identified possible left limit switch failure. Recommended transformer replacement and possible limit switch repair/replacement to restore heating functionality.
Replaced defective main burner unit under warranty on gas furnace. Removed old burner assembly and installed new one, then verified proper flame pattern and combustion with blue flames observed. System operating correctly upon completion.
Addressed leak at residence caused by deteriorating bathtub waste and overflow assembly. Inspection revealed swelling and active leakage at the shut hub connection between floors. Successfully replaced damaged section of waste and overflow components, restoring proper drainage function and eliminating water intrusion to basement ceiling.
Responded to client's concern regarding grinding noise when heating system activated. Upon thorough inspection, determined noise was not originating from furnace but from a loose return air vent near thermostat causing vibration. Secured vent by tightening screws, successfully eliminating the noise issue.
Performed annual furnace tune-up on 3-year-old Arcoaire unit. Conducted full electrical system inspection with all components testing within specifications. Completed preventative maintenance including flame sensor cleaning and hose clearance verification. System is functioning properly with no issues detected.
Responded to no heat call for 15-year-old oil furnace. Diagnosed electrical issue - no power reaching control circuit due to blown 30 amp delay fuse at switch. Temporarily bypassed switch to verify unit operation. Noted absence of ground connection from unit to electrical panel. Advised customer to replace fuse to restore proper operation. System scheduled for upcoming maintenance including orifice replacement and filter change.
Responded to service call for recently installed furnace (27 days old) with water leakage beneath unit. Discovered disconnected exhaust drain hose from collector box. Reattached hose to proper nipple, cleaned up accumulated water, and verified proper operation. System functioning correctly with no further leakage.
Diagnosed 5-year-old natural gas furnace (Goodman model V-B060U_V) displaying error code for inducer pressure switch/condensate switch and blowing cold air. Upon inspection, confirmed control board failure to supply power to inducer motor despite proper triggering sequence. Provided temporary space heater while ordering replacement control board to restore heating function.
Responded to customer complaint of unusual pilot light sound. Performed diagnostic inspection on natural gas Empire heating system. Identified critical safety issue: cracked heat exchanger, along with excessive gas pressure causing torch-like pilot flame. Equipment deemed unsafe for operation due to carbon monoxide hazard. Recommended complete system replacement; customer advised of findings and scheduled follow-up consultation.
Responded to emergency call for toilet valve malfunction that caused significant water leakage. Identified broken nut at bottom of toilet tank as the source of the leak. Replaced water supply line in main bathroom and installed a second preventative water line replacement on adjacent toilet at customer request to prevent future incidents.
Responded to customer-reported water leak around furnace. Upon arrival, found previous leak had dried and condensate pump outlet GFI had been reset by homeowner. Observed minor moisture around condensate trap, tightened all clamps and screws to secure connection. Tested system function by running furnace for 20 minutes with no visible leaks detected. Noted customer may require future service for water filter on humidifier line and water panel replacement.
Successfully replaced warranty heat exchanger with normal access on customer's furnace. Installed new control board and completed necessary warranty paperwork. Unit tested after reassembly and is now operating properly with all systems functioning as designed.
Performed comprehensive tune-up on 4-year-old Lennox furnace responding to customer's concerns about excessive noise and inconsistent heating. Found and replaced severely clogged air filter, identified burnt-out UV bulb, and discovered corrosion developing on burner assembly. All electrical components tested within specifications, condensate lines were cleared, and heat exchanger inspection showed no compromises. System operated properly during 15-minute test run with appropriate temperature rise of 80 degrees. Customer was educated about normal two-stage operation and provided estimate for recommended burner cleaning and UV bulb replacement.
Performed routine maintenance on 2-year-old Lennox natural gas furnace. Identified and repaired small gas leak at the union inside furnace by tightening connection. Completed comprehensive system inspection including all routine components with no additional issues found. Confirmed proper operation after service.
Performed comprehensive maintenance on 2-year-old Lennox furnace. Replaced customer-supplied dirty filter, cleaned condensate lines and critical components, and inspected heat exchanger with no issues found. System demonstrated proper operation with 70° temperature rise and appropriate gas pressure during 15-minute test cycle.
Responded to no-heat call for aging furnace (10+ years). Diagnosed pressure switch fault with water infiltration in burner box and pressure switch tube. Control board failure confirmed by lack of power to inducer motor despite system reset and draining. Observed significant rust damage to burners resulting from water exposure. System requires control board replacement and possible burner assembly replacement, but customer opted to explore full system replacement due to unit age and extent of repairs needed.
Responded to service call to adjust residential water heater temperature settings. Upon arrival, assessed the customer's request and properly adjusted the thermostat to a higher temperature while maintaining safe levels to prevent potential scalding risks. Verified proper operation of the unit after adjustment was complete.