Hurlburt offers heating repairs, maintenance, installations, and replacements in Altoona. This ensures we can help keep our clients warm throughout the coldest days. We service furnaces, boilers, and ductless systems, making it easy to get assistance no matter what system you have.
It’s frustrating and concerning when you realize your heating system is experiencing issues or nearing its end. Our various heating solutions can restore warmth to your home whether you want an upgrade or to fix an issue. We offer standard and emergency HVAC assistance in Altoona.
Heating solutions we provide include:
Hot summer days require having cool, conditioned air flowing through your home. Our team can help make that happen whether you have a ductless system or central AC.
When summer approaches, the days become longer, and the temperatures rise, you need HVAC technicians you can count on. We tackle large and small projects, including installations, replacements, maintenance, and repairs. Our team arrives in fully stocked vans, ready to address any air conditioning situation you’re experiencing.
Cooling solutions we supply include:
Your plumbing system goes through significant wear and tear on a daily basis, especially in the kitchen and primary bathroom. The older the system, the more problems it may experience. Our plumbers in Altoona can address any issue with your system.
When you notice problems with your plumbing, it’s understandable that you don’t want to wait long for help. You can rely on our team for prompt, efficient repair services that help the water flow freely once again. Installations and maintenance are also available.
Plumbing solutions we offer include:
Our electricians in Altoona deliver a wide range of electrical services, including installing EV chargers and whole-home generators. They also provide maintenance, replacements, and repairs, ensuring a comprehensive approach to care for your electrical system.
Homeowners should never attempt any electrical projects on their own. It could lead to personal injury, fires, and even explosions. Our experienced team can perform any project, prioritizing safety and functionality.
Electrical solutions we provide include:
There’s a lot to love about living in Altoona from hanging out at Lake Altoona Park to dining at local restaurants. After a fun day, you don’t want to deal with a problem with one of your major home systems. Thanks to our multiple services, Hurlburt can help make your house safer, more comfortable, and more functional.
No matter where you live in Altoona, our plumbers, electricians, and HVAC technicians can assist you with your home needs. You’ll find our trucks in several local neighborhoods, including:
Our more than 65 years of industry experience means you can count on us to provide consistent, exceptional service. We employ a team of skilled technicians, electricians, and plumbers who love what they do, and it shows. Many of our clients have written positive online reviews about Hurlburt over the years. We invite you to read what they’ve had to say so you can know what to expect during your own appointment. Welcome to the Hurlburt family!
Contact Hurlburt today for outstanding plumbing, electrical, and HVAC services in Altoona.
Hurlburt Heating & Plumbing has completed 20 jobs in Altoona, WI between February 2026 and March 2026.
The most recent job was on March 19, 2026.
Hurlburt Heating & Plumbing has completed 431 jobs in Altoona, WI in the last 12 months. The first job there was in October 2015.
Responded to service call for Lennox furnace displaying error code 163 (refrigerant detection). Diagnosed RDS (Refrigerant Detection System) error on thermostat. Cycled power to temporarily clear the code and verified refrigerant pressure at 150 psi, which is within normal range for ambient temperature. Recommended replacement of RDS sensor/board and completed part order form for the component.
Responded to service call for a basement sink with foreign object obstruction. Discovered the trip lever was rusted off on the drain, allowing items to fall into the plumbing. Replaced the entire pop-up assembly on the Mansfield porcelain sink and verified proper operation with leak testing.
Diagnosed and repaired slow leak under upstairs bathroom sink by installing missing trap nut on drain assembly. Installed customer-supplied faucets in both upstairs and downstairs bathrooms, eliminating existing drip and restoring proper functionality to both fixtures.
Conducted comprehensive plumbing inspection with water testing as requested. All plumbing systems functioning properly with no major issues detected. Observed minor corrosion on angle stop feeding dishwasher under kitchen sink; documented condition with photos of water heater installation and PVC piping configuration in utility area.
Responded to service call for a furnace with intermittent heating issues. Diagnosed system showing alternating red/green error lights. Hot surface ignitor was functioning properly, but gas valve was receiving constant 26-27V power. Upon testing, furnace operated normally multiple times after reconnecting gas valve. Discussed repair versus replacement options with homeowners given the age and budget-friendly nature of the unit.
Responded to no-heat complaint at residential trailer unit. Diagnosed system attempting ignition but failed due to faulty igniter (confirmed with 0 ohms reading). Heat exchanger inspection showed no compromises with all components within specifications. Installed temporary hot rod igniter as immediate solution, restoring heating function, with scheduled follow-up to replace with proper OEM igniter due to insulation concerns on temporary part.
Responded to no heat call for 25-year-old furnace. Diagnosed system running in lockout mode with dirty flame sensor despite clean filter and clear venting. Performed comprehensive tune-up, cleaned flame sensor, and noted inducer motor beginning to fail. System tested properly after service with good temperatures and flame pattern; customer advised to monitor for recurring issues and consider replacement options due to equipment age.
Performed maintenance agreement service on HFR furnace of unknown age. System shows signs of previous repair work and significant wear. Inspected thermostat (set to 70° heat) and documented equipment condition, noting accumulated dust and debris requiring cleaning. Completed standard furnace tune-up procedures per 12-4 agreement specifications.
Performed furnace tune-up on 1995 Trane 80% efficient natural gas furnace that replaced previous oil furnace. Conducted thorough inspection including heat exchanger evaluation with no crimp cracks detected and carbon monoxide testing showing 0 ppm after 10+ minutes of operation. Homeowners plan to replace both furnace and chimney in the future.
Responded to no heat service call on 8-year-old furnace. Diagnosed failed Hot Surface Ignitor (HSI) as root cause. Replaced HSI and installed new customer-supplied filter. System now operational. Customer expressed dissatisfaction with equipment; sales advisor scheduled for follow-up consultation regarding potential replacement options.
Diagnosed intermittent heating issue on older furnace that was cycling improperly. Upon inspection, identified faulty control board connection when manipulating the Molex plug caused flame cutout and pressure switch code. Replaced control board, reconnected all wiring properly, and performed complete system testing to verify proper operation. Unit now functioning correctly with stable flame and normal operation.
Completed routine plumbing inspection as part of rewards program. Found water pressure running high and adjusted it to appropriate levels. Visual inspection of P-trap assembly and adjacent plumbing showed all components in good working condition with no signs of leaks or corrosion.
Responded to a no-heat service call for aged system that was previously serviced for thermostat issues. Diagnostic testing revealed furnace shutting down on pressure switch due to significant water accumulation in draft housing. Identified leak in draft housing causing operational failure. Discussed equipment age with homeowner and recommended system replacement consultation rather than extensive repairs on aging unit. Thermostat was confirmed operational with proper settings and connections.
Performed routine furnace tune-up and identified multiple issues requiring attention: inducer motor operating with excessive noise and higher-than-rated electrical draw, system operating with elevated temperature rise, and weak blower capacitor. Completed maintenance including filter replacement, drain cleaning, and electrical component inspection; provided repair recommendations for identified deficiencies.
Diagnosed loud rattling noise in Amana PTAC Unit 2. Inspection revealed damaged bushing connecting blower wheel to motor, causing motor to spin freely and intermittently catch the wheel. Recommended replacement of either bushings or entire blower wheel to resolve the issue, or consideration of complete unit replacement if more cost-effective.
Responded to service call for malfunctioning thermostat. Diagnosed non-responsive controls after homeowners returned to residence. Removed existing thermostat, installed new Honeywell Home ProSeries T4 thermostat, connected appropriate wiring to terminal block, and verified proper heating system operation. Demonstrated thermostat functionality to homeowner before completing service.
Performed comprehensive maintenance on two furnaces: newer Lennox unit (4-5 years old) and older Evcon model (20 years old). On the Lennox, reattached disconnected water exhaust pipe using PVC cement for permanent connection. For the Evcon furnace, replaced cracked drain hose and broken barbed fitting with new 3/8" vinyl tubing, secured with silicone sealant. Both units were tested and confirmed to be operating within specifications.
Responded to no heat call for a furnace displaying alarm code 291 with no air flow from vents. Diagnosed issue with 10-month-old system that was recently installed. Customer had already replaced the plug filter prior to arrival. Provided customer with estimate for new furnace-mounted humidifier to replace current ultrasonic unit.
Responded to callback regarding noisy PTAC unit in room 12 that was previously serviced. Diagnosed excessive noise after recent blower motor and wheel replacement. Removed and replaced both components with new parts, resolving the noise issue.
Performed scheduled furnace tune-up on Lennox system. Cleaned routine components, tested equipment operation, and discussed filter compatibility issues with homeowner. Recommended proper replacement filter (Healthy Climate Carbon Clean 16, 16"x25"x5", part #X6672) to replace currently used incompatible filters.