Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
When you need the expertise of a certified plumber in Shakopee, our team is here to help. From minor repairs to extensive installations and remodels, we’re committed to keeping your home’s water systems operating smoothly. Our team boasts experience in working with both modern and traditional plumbing systems, giving them the skills and know-how to handle any project.
Electrical systems are complex and can be dangerous without proper training. When you hire a professional electrician in Shakopee, you can have confidence that your home’s electrical system is in good hands. At Hurlburt, we’re here to keep your system safe and efficient. Whether you need new lighting, panel upgrades, or emergency electrical repairs, we’ll complete the job with precision and care.
For Shakopee plumbing, electrical, heating, and cooling services, trust the team at Hurlburt. Call us today to schedule a service with our team.
Performed follow-up annual cooling maintenance visit to address concerns from previous service call. Fully disassembled condensing unit, performed thorough coil cleaning and component inspection to ensure proper system operation. Documented equipment condition with photos of HVAC system and electrical panel for service records.
Responded to warranty callback for insufficient cooling in one bedroom of recently installed HVAC system. Measured supply air temperature at floor register, confirming output of 52-53°F. Assessed airflow distribution and determined room has only one return air grille for its size, resulting in inadequate air circulation and heat removal. Recommended installation of additional return air vent to improve air exchange and cooling performance in affected bedroom.
Responded to downstairs shower with continuous drip caused by stripped hot and cold valve handles that could not be turned off completely. Upon inspection, found severely corroded cartridges with visible verdigris formation on valve assemblies and deteriorated internal components preventing proper shutoff. Replaced both hot and cold cartridges to restore full operational control and eliminate leak.
Completed spring AC tune-up on single-zone system with 410A refrigerant. Performed comprehensive maintenance on condenser unit and indoor air handler, including inspection of filter, drain pan, blower motor, electrical wiring, components, coil, and capacitor. Verified amp draw on compressor, motor, and contactor within normal parameters. Confirmed refrigerant temperatures, pressures, and temperature split all operating correctly. Addressed homeowner concern regarding insufficient humidity control by adjusting dehumidifier setting from normal to maximum. All system components tested and operating properly with no mechanical issues found.
Completed pre-paid plumbing maintenance visit with scheduled arrival window between 12:00 PM and 5:00 PM. Conducted comprehensive inspection of plumbing systems including water heater and associated components. Inspected Bradford White water heater unit, verified proper operation, checked pressure relief valve, and examined copper supply and discharge piping connections. All plumbing systems found to be functioning properly with no issues identified or repairs required.
Responded to callback for air conditioning system not turning on. Upon inspection, discovered damaged 2-wire conductor running to condensing unit was shorting out, causing system failure. Replaced damaged section of wiring to restore proper electrical connection. Verified system operation with 21-degree temperature split across evaporator coil, confirming unit is now cooling properly.
Completed comprehensive AC tune-up and maintenance on one R22 condenser unit with outside ambient temperature at 76 degrees. Performed full system inspection including air filter, thermostat operation, temperature split analysis, condenser unit, evaporator and condenser coils, blower motor, capacitors, compressor function, refrigerant charge level, and condensate drain line. All AC system components tested and found operating within normal parameters at time of service. During inspection of mechanical room, identified active water leak from residential water heater tank with visible moisture accumulation and water pooling. Recommended immediate water heater replacement due to tank failure and scheduled follow-up appointment for comfort advisor to provide replacement quote and options.
Responded to no hot water complaint on 10-year-old American ProLine tanked water heater. Diagnosed pilot light failure where flame would ignite when button depressed but immediately extinguished upon release. Tested thermopile output and measured 700mv DC, which indicated adequate thermocouple function. Determined Honeywell gas control valve was faulty and preventing pilot from remaining lit despite proper thermopile voltage. Provided estimate for gas valve replacement versus full water heater replacement and awaited approval for repair.
Performed comprehensive AC tune-up on Daikin condensing unit. Inspected indoor air handler, confirmed filter in good condition, and verified drain line clear and draining properly. Measured temperature split at 15.4°F across the system. Cleaned condenser coils on outdoor unit and inspected all major electrical components, with capacitor and contactor testing within normal operating range. During refrigerant circuit evaluation under 76°F ambient conditions with direct sunlight on condenser, system appears to be undercharged. Customer will contact utility provider regarding potential electrical concerns before proceeding with refrigerant service.
Responded to no hot water call on Westinghouse Premium boiler less than 10 years old. Found unit completely inoperative with tripped breaker caused by slow leak from top-mounted air bleeder valve that dripped water into internal components, shorting out electrical system. Drained system completely and replaced failed air bleeder valve assembly. Replaced damaged circuit board and control components that sustained water damage from leak. Refilled system, purged air from lines, and restored unit to full operation with hot water service confirmed.
Sold and installed a Moen Chateau Chrome L2353 tub and shower valve system with matching chrome spout and showerhead. The Posi-Temp pressure-balancing valve assembly was mounted to copper supply lines, featuring a single lever handle for temperature control. Return visit scheduled to complete final installation and testing of the shower valve assembly.
Responded to warranty call for water leakage from AC system into bedroom. Upon inspection, determined system was cooling properly but condensate drain line had improper pitch causing audible dripping noise and water backup. Adjusted condensate line pitch to ensure proper drainage and eliminate noise. Noted water intrusion near bathroom exhaust fan, which appears unrelated to HVAC system. Recommended customer contact duct cleaning company to service bathroom fan and associated ductwork to address moisture issue in that area.
Responded to no cooling call on recently installed 2024 AC system. Found main breaker tripping even with outdoor disconnect removed, indicating electrical issue upstream of HVAC equipment. Inspected electrical panel and confirmed breaker fault independent of AC system operation. Recommended scheduling licensed electrician to diagnose and repair electrical panel issue before system can be safely restored to operation.
Responded to cooling complaint on 14-year-old geothermal system not maintaining thermostat setpoint. Upon inspection, found evaporator coil completely iced over with frozen lineset extending to geothermal heat pump. Identified root cause as insufficient airflow due to blower speed set incorrectly at low setting. Adjusted blower speed from low to medium-high to increase airflow across evaporator coil. Disabled cooling mode at thermostat and set fan to continuous operation to facilitate ice thaw process. Return visit required to verify complete system thaw and confirm proper cooling operation after airflow correction.
Responded to shower valve malfunction where the handle had corroded and fallen off, rendering the fixture inoperable. The tenant had shut off water supply to the affected shower prior to arrival. Attempted to extract the existing cartridge for replacement with a new unit to restore proper function to the shower valve assembly.
Responded to service call regarding outdoor faucet that had frozen the previous fall with concerns about potential pipe damage and leaks behind refrigerator. Conducted thorough inspection of the outdoor faucet connection and associated plumbing using pressure gauge to test system integrity. Verified water pressure readings and examined all accessible piping and connections in the area. Inspection confirmed no leaks present in the system, no burst pipes detected, and all plumbing components functioning properly. Customer advised that outdoor faucet and water supply line are intact and safe to resume normal operation.
Completed comprehensive plumbing inspection and repairs addressing multiple findings from property inspection report. Installed new main shut-off valve to replace corroded existing valve on water main line entering the structure. Corrected improper water heater venting configuration to meet code requirements and ensure safe exhaust ventilation. Repaired leaking drain assembly under upstairs bathtub fixture. Addressed leak under bathroom sink drain. Assessed corroded copper water main piping showing significant oxidation and deterioration near floor penetration, documenting condition for future repair consideration. Evaluated sump pit water accumulation and confirmed absence of sump pump system. Documented utility sink requiring replacement due to cracked basin. All accessible repairs completed during single service visit, with photographic documentation provided for items requiring municipal coordination or future attention.
Performed comprehensive air conditioning tune-up on 3-year-old residential cooling system currently under manufacturer warranty. Verified refrigerant charge levels within proper operating range using digital manifold gauges, confirming superheat and subcooling readings within specification. Conducted complete system inspection including all electrical components, contactors, capacitors, and safety controls. Evaluated outdoor condensing unit operation, verified proper fan motor function, and inspected condenser coil condition. All components tested and found operating properly within manufacturer specifications. System confirmed fully operational with no deficiencies noted.
Responded to service call for basement bathroom fixture assessment. Evaluated existing toilet and lavatory faucet for replacement and provided detailed estimates covering both scenarios: contractor-supplied fixtures and customer-supplied fixtures. Customer requested time to review options and will contact office with decision on fixture procurement method and scheduling of installation work.
Replaced defective exterior hose bib (spigot) and faulty shower valve cartridge. The outdoor copper spigot mounted on the building's exterior wall was removed and replaced with a new frost-free unit, and the interior shower valve cartridge was replaced to restore proper water flow and temperature control.