Furnaces, boilers and heat pumps are the most common heating systems in Elk Mound. We’ll go over the benefits and drawbacks of each option so that you fully understand them. Many homeowners pair a heat pump with a furnace. The heat pump provides cooling during the summer and efficient heating during the winter. When the temperature drops below freezing, the furnace kicks on. Having this reliable form of backup heat ensures you never have to worry about staying warm.
Central AC is an excellent option for homes that prefer consistent comfort and powerful cooling. We’ll perform load calculations to choose the correct size equipment. Undersizing and oversizing both waste energy and increase your cooling costs. They also result in hot and cold spots that make the home uncomfortable. Our accurate sizing process avoids these issues from the start.
If you want the most precise form of cooling, we’ll recommend a zoned setup. You’ll have room-by-room temperature control, which is great for homes with multiple floors. When you need an AC repair in Elk Mound, WI, help is just a phone call away.
Remodeling your kitchen or bathroom? If so, we can do all of the plumbing upgrades. If you’re installing a garbage disposal, we may need to add a dedicated circuit. This helps keep the breaker from tripping when using the new appliance. If you want to update the bathroom with a new toilet, we can install a low-flow model that saves water.
If you’re constantly running out of hot water, it may be time to go tankless. Tankless water heaters not only provide continuous hot water but also use less energy. This means you save money on utility bills. And because they don’t require a storage tank, there’s a lower risk of leaks and flooding.
Our electricians in Elk Mound, WI have extensive training for installing and fixing electrical systems. If you want better airflow in your home, we can install new ceiling fans.
Remodeling often requires adding new switches and outlets. We’ll consider the home’s layout and lighting when choosing where to place them.
We’ll inspect your panel to make sure it has adequate capacity. Upgrades to breakers and wiring are sometimes necessary for safety or performance reasons. You may need a full-panel upgrade to add an EV charger. 100-amp panels don’t have enough capacity to safely support EV charging. By adding a larger panel with ample capacity, you won’t have to worry about overloads.
Many homes near County Road U need sump pumps to manage spring snowmelt and heavy rainfall. Our team installs these devices, including submersible, battery backup, and pedestal types.
Homeowners along Highway 93 often have us install whole-home generators to prepare for storm-related power outages. We’ll connect the transfer switch and set up the wiring so that everything functions reliably.
If you live near Beaver Creek Reserve and want better indoor air quality, we can install a whole-home air purifier. Other solutions for indoor air quality in Elk Mound, WI include whole-home humidifiers and dehumidification systems.
Our customers love our people-driven culture. They frequently leave us 5-star reviews, praising us for our professionalism and reliability. You can read through thousands of them to see why they keep choosing us.
We come to all jobs with fully stocked trucks to fix most problems in one visit. If we ever have to turn off the home’s water or electrical supply, we’ll let you know in advance. Our fast service for emergency HVAC in Elk Mound is greatly appreciated when there are refrigerant leaks or sudden system breakdowns. We’ll arrive quickly to restore comfort with a long-term solution. The Hurlburt Family Rewards Club helps you stay on top of essential maintenance that improves the home’s energy performance and comfort.
Contact Hurlburt today to book service for electric, plumbing, HVAC, and indoor air quality in Elk Mound, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Elk Mound, WI between October 2026 and November 2026.
The most recent job was on November 12, 2026.
Hurlburt Heating & Plumbing has completed 178 jobs in Elk Mound, WI in the last 12 months. The first job there was in October 2015.
Evaluated the bathroom remodel scope for toilet installation and vanity plumbing, including connecting the toilet to the existing drain and setting the vanity with its drain tied into the wall drain. Inspected the open wall cavity, where existing PEX supply lines with push-fit fittings are marked and routed for hot and cold connections to the vanity valves. Documented the rough-in conditions with photos to support an estimate for the full remodel.
Responded to a no-heat call and found the furnace failing to ignite due to the gas supply shutoff valve being closed. Opened the gas supply, and the furnace ignited immediately on the first call for heat. Monitored a full heating cycle to verify proper ignition, stable burner operation, and no overheating or limit trips, and confirmed the system was operating normally at completion.
Responded to an active leak at a 2-year-old A.O. Smith tank-type water heater and determined the leak was originating from the tank itself, indicating internal tank failure that is not repairable. Provided the customer with a warranty replacement unit and performed a water quality test to identify the cause of the premature tank failure.
Performed a pre-season furnace tune-up on an 8-year-old unit, finding the secondary heat exchanger and A/C evaporator coil heavily contaminated with dirt and debris. Cleaned both components, but the furnace continued to trip on the high limit switch. Increased blower fan speed by 75 CFM to improve airflow and heat dissipation, which resolved the high limit trips and restored normal operation.
Responded to a no-heat call on a 16-year-old system where the blower cycled on and off intermittently. Diagnosed a failed run capacitor and a blower motor struggling to start, then replaced both with a 1/2 HP, 115V, 1075 RPM, 4-speed direct drive blower motor and a new capacitor. Verified proper blower startup and operation, restoring normal heating.
Performed annual furnace maintenance on a 17-year-old unit, including a visual inspection of the heat exchanger using an inspection camera, with photos documenting its condition. Reviewed the heat exchanger style and design with the customer and discussed the unit's age and the long-term service outlook. Also documented the water heater installation (power-vent, Bradford White) and noted no visible rust, frost, or damage.
Performed annual maintenance on boilers, water heaters, unit heaters, tube heaters, and circulator pumps across multiple buildings. Restored operation of the parlor and vet office heaters, cleaned the parlor tube heater fan, cleared a damper fault code on the main barn water heater by restoring the damper and locking it open, and brought both calf barn heaters into working order. Identified a failed gas valve and leaking expansion tank on the commodity shed water heater, a loose return sensor connection on the parlor boiler, a control board and supply sensor needed for the vet office boiler, and a failed cow lane circulator pump requiring a replacement relay; parts have been submitted for pricing and repairs.
Performed a preventive maintenance tune-up on the approximately three-year-old gas furnace, which was operating properly with no reported symptoms. Inspected internal components with the lower access panel removed, cleared the condensate and pressure hoses, and verified that electrical connections and controls were within specification. Unit was left in normal working order.
Diagnosed a no-heat condition on a 12-year-old system caused by a thermostat failing to send a call for heat, and also found a sticking contactor on the outdoor condensing unit causing the AC to run unintentionally. Replaced the thermostat with a new Honeywell Home digital unit and installed a new contactor, then verified proper operation. The remainder of the furnace appeared serviceable, though due to its age, replacement planning was recommended; AC function could not be fully tested due to low ambient temperatures, but the unit no longer runs when not called.
Responded to a no-heat call on a 1989 Trane gas furnace and diagnosed a failed hot surface igniter as the cause of the no-heat condition. Replaced the igniter with a new part, then verified proper ignition sequence, stable burner flame, and normal blower operation through a full heating cycle. Furnace is operating correctly.
Cleared a clogged toilet by plunging the drain, restoring proper flow. Inspection of the tank revealed heavy mineral and rust buildup and deteriorated internal components (fill valve and flapper), indicating the aging fixture is beyond practical repair. A replacement estimate was provided to the customer for consideration.
Responded to a no-heat call on a 10+ year old gas furnace and diagnosed a failed hot surface igniter, which prevented ignition, along with a line voltage (L1) polarity error flagged by the Comfort Advisor diagnostic. Replaced the hot surface igniter and the Comfort Advisor, then verified proper ignition sequence, flame sensing, and normal heating operation.
Responded to a no-heat call on a 19-year-old gas furnace with a blinking red diagnostic LED and non-functioning blower. Inspected the cabinet and inducer assembly and used a borescope to examine internal heat exchanger components, then ran the system through multiple heating cycles, which operated normally. Based on the symptoms and the intermittent nature of the fault, the likely cause is an intermittently failing gas valve; recommended gas valve replacement and a comfort advisor consultation.
Responded to a complaint of the in-floor heating zone failing to shut off and the upstairs living room overheating. Diagnosed the zone thermostat as sticking in the calling-for-heat position, corrected the fault to restore proper call-for-heat cycling, and tested the system through multiple heat cycles to confirm the zone now shuts off normally. This was the first heating-season operation since the combi boiler installation, and no installation-related defects were identified.
Replaced the boiler igniter under manufacturer parts warranty and corrected a previous improper installation by wiring the three in-floor heating circulator pumps to a dedicated outlet powered through a relay at the boiler. When a domestic hot water call is active, the relay opens and cuts power to the in-floor pumps so all boiler output is directed to the indirect tank, then closes upon satisfaction to restore in-floor heating. Cleaned the heavily soiled boiler, completed the job, and verified proper system operation.
Diagnosed a no-heat condition on a 10-year-old gas furnace that was failing to hold flame and displaying a solid red status light before blinking. Inspection found a failed gas valve, a leaking collector box, and corroded burners, with heavy rust and corrosion deposits visible in the cabinet floor and surrounding components. Repair recommendations include replacing the gas valve and collector box and cleaning the burners.
Responded to a no-heat call on a two-year-old condensing boiler locked out on a 004 flame-not-detected fault. Reset the unit and ran it through multiple heat cycles over approximately 30 minutes, confirming consistent ignition and operation with no repeat lockout. Recommended a boiler cleaning, since the unit has not been serviced since installation, and provided an estimate for the work along with information on a maintenance membership program.
Diagnosed a complete loss of water in the residence by verifying flow at the pressure tank tee spigot, isolating the fault to the water softener. Placing the softener in bypass restored water to the house, indicating air and sediment lodged in the softener unit, and the pressure gauge showed low system pressure with heavy mineral scaling and corrosion on the adjacent fittings. The softener remains in bypass pending service by the equipment provider, as the unit is rental equipment.
Replaced a corroded ball valve in the utility room with a new brass ball valve, cutting out the failed section and installing press-style copper fittings to restore a leak-free connection. Also replaced the Delta shower cartridge with a customer-supplied unit, restoring proper function of the shower valve.
Diagnosed a no-heat condition on a 1986 standing-pilot furnace and verified the customer-installed replacement control transformer was wired correctly. Relit the pilot and found a weak pilot flame, and the gas valve is not passing gas to the burners. Recommended replacement of the pilot assembly and gas valve, with parts pricing to be obtained.